6.

Turn the coupling nut clockwise and tighten to a full stop. The 
regulator will seal on the back-check feature in the LP cylinder 
valve, resulting in some resistance. 

An additional one-half to 

three-quarters turn is required to complete the 
connection. Tighten by hand only – do not use tools.

NOTE:

If you cannot complete the connection, disconnect regulator and 
repeat steps 5 and 6. If you are still unable to complete the 
connection, 

do not use this regulator!

Straight

Hold coupling nut and regulator
as shown for proper connection
to LP cylinder valve.

DANGER

• Do not insert any tool or foreign object into the valve 

outlet or safety relief valve. You may damage the valve 
and cause a leak. Leaking propane may result in 
explosion, fire, severe personal injury, or death.

Leak Testing Valves, Hose and Regulator

1. Turn control knob to OFF.

2.

Be sure regulator is tightly connected to LP cylinder.

3.

Completely open LP cylinder valve by turning hand wheel 
counterclockwise. If you hear a 

rushing sound

, turn gas off 

immediately. There is a major leak at the connection. 

Correct 

before proceeding

.

4.

Brush soapy solution onto areas circled below.

5. If “growing”

 bubbles appear, there is a leak. Close LP 

cylinder valve immediately and retighten connections. 

If leaks 

cannot be stopped do not try to repair. 

Call for replacement 

parts. Order new parts by giving the serial, model number and 
name and part number of items needed (see parts list) to the 
Grill Service Center at the number listed on front cover.

6.

Always close LP cylinder valve after performing leak test by 
turning hand wheel clockwise.

• This appliance is not intended to be installed in or on a 

boat.

is not intended to be installed in or on an 

RV.

• Never attempt to attach this 

to the self-

contained LP gas system of a camper trailer or motor 
home.

• Do not use 

until leak-tested.

• If a leak is detected at any time, STOP and call the fire 

department.

• If you cannot stop a gas leak, 

immediately

 close LP 

cylinder valve and call LP gas supplier or your fire 
department!

This appliance

appliance

this appliance

 

 

 

WARNING

  7

Содержание 10101480

Страница 1: ...del 10101480 The following are trademarks registered by W C Bradley Co in the U S Patent and Trademark Office Caldera Charcoal2Go Char Broil American Gourmet Bandera Brush Hawg CB 940 Char Diamonds Ch...

Страница 2: ...m of any structure combustible material or other gas cylinder 3 Never operate this appliance within 25 ft 7 5 m of any flammable liquid 4 If a fire should occur keep away from the appliance and immedi...

Страница 3: ...nd the regulator valve assembly supplied The appliance installation must conform with local codes or in their absence of local codes with either the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural...

Страница 4: ...ed to 160 F NEVER partially cook meat or poultry and finish cooking later Cook food completely to destroy harmful bacteria Use a meat thermometer to ensure proper internal food temperatures Storing Yo...

Страница 5: ...ontrol knob and LP cylinder valve Turn coupling nut counterclockwise by hand only do not use tools to disconnect Install safety cap onto LP cylinder valve Always use cap and strap supplied with valve...

Страница 6: ...nd certify their cylinders Exchange your cylinder only for an OPD safety feature equipped cylinder as described in the LP Cylinder section of this manual Always keep new and exchanged LP cylinders in...

Страница 7: ...y turning hand wheel counterclockwise If you hear a rushing sound turn gas off immediately There is a major leak at the connection Correct before proceeding 4 Brush soapy solution onto areas circled b...

Страница 8: ...as carport garage porch covered patio or under an overhead structure of any kind Use appliance at least 3 ft from any wall or surface Maintain 10 ft clearance to objects that can catch fire or source...

Страница 9: ...eplace valve assembly before using this appliance Turn knob to ON position then turn back to position Valve should turn smoothly Hose Check Before each use check to see if hose is cut worn or kinked R...

Страница 10: ...L SPIDER WEBS INSIDE VENTURI If you notice that your the appliance is getting hard to light or that the flame isn t as strong as it should be take the time to check and clean the venturi s In some are...

Страница 11: ...r failure or damage resulting from acts of God improper care and maintenance grease fire accident alteration replacement of parts by anyone other than Manufacturer misuse transportation commercial use...

Страница 12: ...se Regulator S 1 Heat Shield T 1 Lift Hook K 2 Side Handle Springs L 1 Control Panel M 1 Control Knob N 1 Top Cover Key Qty Description A 1 Outer Body B 1 Inner Body C 1 Body Top Ring D 1 Burner E 1 H...

Страница 13: ...ew 10 24x3 8 Screw located at each end of the grease rails Qty 12 10 24 Keps Nut 10 24 Keps Nuts Tools required for assembly Phillips Screwdriver Not Supplied Small Adjustable Wrench Not Supplied 13 W...

Страница 14: ...his time Be sure two threads are engaged into the appliance body A1 Slide the control panel slots under the screws heads while holding the heat shield in position between control panel Secure with 1 e...

Страница 15: ...ray 15 Foil Tray Liner 4 Turn appliance upright on its legs Push on control knob and ignitor knob A If not already assembled slide handle springs onto side handles B Attach side handles to appliance b...

Страница 16: ...theinfraredcookingsystem NOTE Before cooking on your appliance for the first time refer to the Outdoor Grilling Guide on how to prepare the appliance for cooking It is recommended that you season your...

Страница 17: ...NOTES 17...

Страница 18: ...egulator See LP Cylinder Leak Test and Connecting Regulator to the LP Cylinder Replace LP cylinder Turn off LP cylinder valve Return LP cylinder to gas supplier Turn off LP cylinder valve Remove regul...

Страница 19: ...t regulator and leak test Turn on LP cylinder valve wait 30 seconds and then light appliance Turn off knob and LP cylinder valve Disconnect coupling nut from cylinder Reconnect and retry Refill LP cyl...

Страница 20: ...REGTEMP REV02 Warranty Registration Department P O Box 1240 Columbus GA 31902 1240...

Отзывы: