Installation
The control box can be used on the burners with or without hea-
ter.
If the heater is damaged, insert the connection 5)(Fig. 15) (
brid-
ge
) in the control box in order to the working without heater until
the heater restores.
On the burner with heater, the connection 5) (
bridge
) must be re-
moved and it is necessary to connect the cables of the resistan-
ces and the thermostat.
2.7.3
Wiring diagrams
Key to lay-out
C
– Capacitor
E
– Ignition electrode
F
– Photoresistance
MV
– Fan motor
R
– Heater 25W
S3
– Remote lock-out signal (230V - 0.5A max.)
TA
– Start termostat
TB
– Burner-earth
TL
– Limit thermostat
TS
– Safety thermostat
T6A
– Fuse
V1
– Oil valve
X7
– 7 pin plug
XP7
– 7 pole socket
WARNING
Fig. 15
5
S7735
L
N
TL
S3
X7
XP7
TB
E
F
V1
R
MV
C
TS
T6A
Fig. 16
D9837
TIGRA 2 CF 510
CONTROL BOX
535RSE/LD
~ 50Hz - 230V
Black
Blue
White
TO BE DONE BY
THE INSTALLER
CARRIED-OUT
IN FACTORY