Important: Some equipment will not work or may be damaged if
polarity is reversed. Damage caused by reversed polarity is not
covered under your warranty. Be sure polarity is correct when
you connect your boat to shore power.
Shore Power Connection
To connect:
Instructions for models that have shore power connectivity.
1. Make sure all shore power cords and adapters are clean and
dry before use. If they are dropped overboard, do not use until
completely dry and checked by a qualified marine electrician.
Keep shore power inlet covers tightly closed when not in use.
2. Get permission from the marina before connecting to a dock
receptacle and ask if the “polarity” and ground are correct and
when they were last checked.
3. Make certain there are no swimmers in the water around your slip.
4. Shut off each individual breaker, the boat’s main AC circuit breaker,
and dock breaker before connecting the shore power cord.
5. Connect the shore power cord to the boat first, then connect the
cord to the dock receptacle and turn on the dock breaker.
Ensure dockside breaker is OFF.
6. Thread the locking ring on the outlet to secure cable and pre-
vent accidental unplugging and turn the dock breaker on the
dock to the ON position.
7. Check the boat’s “polarity” alarm or light (if equipped) on the AC
panel as soon as the dock breaker is turned on. If the polarity is
incorrect, shut the dock breaker off and disconnect the dock end
of the shore power cord immediately. Report the problem to the
marina. The marina should contact a qualified electrician to
make corrections.
8. Turn ON the AC main shore power breaker (if equipped).
Individual AC breaker and switches can now be energized.
To Disconnect:
1. Shut off each individual breaker first then shut off the boat’s
main AC circuit breaker.
2. Turn off the dock breaker.
3. Disconnect the dock end of the shore power cord first.
4. Clean and dry the shore power cord. Store it in a dry location on
board the boat.
5. You are now disconnected to shore power
Ground Fault Interrupter Outlet
The ground fault interrupter outlet provides protection against cur-
rents which can be dangerous even though they do not overload
circuit breakers. These outlets which have a test and reset switch in
the middle of the faceplate provide ground fault protection to the
head and galley outlets on the boat. If there is a difference of more
than 5 milliamperes, a safety switch trips in the outlet and interrupts
the circuit. This protects the person who is operating the electrical
3-4
CAUTION:
To prevent damage to electrical system, never oper-
ate shore power system at low voltage.
CAUTION:
Electric shock is possible if you turn on main cabin
breaker when reversed polarity is present.
Содержание 2012 SSi
Страница 15: ...1 7...
Страница 16: ......
Страница 20: ......
Страница 49: ...3 14...
Страница 74: ...5 16...
Страница 75: ...5 17...
Страница 93: ......
Страница 101: ......
Страница 108: ...WIRING SCHEMATICS 12 12 1 196 206 216 SSI...
Страница 109: ...12 2 196 206 216 SSI...
Страница 110: ...12 3 226 SSI...
Страница 111: ...12 4 226 SSI...
Страница 112: ...12 5 246 SSI...
Страница 113: ...246 SSI 12 6...