Multiple Receiver Operation
Emitter Expansion Application 2
Expanding Into 2 Hubs
Alternative Receiver Hookup
Direct plug-in cable
(Included with IR-2400)
When connecting IR receivers to the IR-1203,
there are two valid methods.
Method 1: Use the 3-wire screw terminal
connections as shown in the “Typical Application”
diagram.
Method 2: Use the direct plug-in cable provided
with the IR receiver.
To simplify the connection of multiple IR receivers,
a connecting block such as model C-1201(not shown)
can be used. The C-1201 can provide connections for
up to 8 IR receivers, allowing them all to connect to
the IR-1203.
Connect all S, G and +V together.
May connect up to 8 receivers.
Using IR-3002,
up to 16 IR emitters
may be controlled
One power adaptor
powers both units
Standard stereo
mini-plug cable
Using IR-3002,
up to 32 IR emitters
may be controlled
One power adaptor
for every 2 IR-2103
One power adaptor
for every 2 IR-2103
Note that only
S and G
are connected