background image

Programming a New Channel

Valid channels are 14 thru 64 for UHF and 65 thru 125 for CATV
Channels 95-99 are not available. Channels 21 thru 62 are for Pal.

Channel Spacing:

Skip at least one number between the new channel and the closest
existing UHF/CATV channel. 

(example 14 and 16: OK   14 and 15: Unacceptable)

Error Indication:

If an error occurs or an incorrect channel is entered, the LED will
flash quickly for one second and return to previous settings.

Cable HRC and IRC considerations: 

Most cable services use IRC frequency assignments. This is the
default for the 5115. However, if the cable services uses HRC or 
the TV appears to search for the “created channel”, program the
channel injector for HRC. 

For HRC enter 98. Reset to IRC by entering 99.

Entries 98 and 99 are for setting HRC or IRC only. They will not
change the channel number.

With programming complete, test each TV in the system to see that it is
receiving the new channel.

10

Specifications: typical @ 25°C ± 5° C  

5115HHR / 5115BID             5115PAL(AUS)

video input format                        NTSC                                    CCIR

input signal

1.0 V peak-to-peak @ 75

output

12dBmV normal - 15.5dBmV maximum

input connectors

3 RCA (video + audio left + audio right)

loop-thru connectors

3 RCA (video + audio left + audio right)

video termination                   75

or > 1 M

in “loop” position (selectable)

tuning range UHF                       14 to 64                         21 to 62(28 to 67)

CATV                     65 to 125

A                                                                                   

power supply

included with product

mains power                            105 to 125                              210 to 250 

output of power supply                                  15VDC 600mA

general 

width x height x depth            injector module                         wall plate

6.5” x 3.5” x 1.25”                 1.25” x 4.0” x 1.75”

(16.3cm x 9cm x 3.2cm)       (3.2 cm x 10.5cm x 4.0cm)

shipping weight

2 lbs (0.9 kg)

operating temperature

–4°F to 131°F  (–20°C to 55°C)

excluding channels 95 through 99

11