Chandler BBL10 Скачать руководство пользователя страница 6

6

Model TA
Thin Profile Air Defrost Reach In Unit Cooler

APPLICATION

Model TA is a thin profile unit which mounts in the top of a
refrigerator and makes the entire top shelf area usable.  The
attractive low silhouette makes this unit cooler particularly
desirable for display type refrigerators.  It can also be used in
back bars, under counter cabinets or wherever space is at a
premium.

For 35˚ to 45˚F fixtures at 10˚F to 15˚F TD applications with 16
hours maximum compressor run time per day.

FEATURES

• Textured aluminum cabinet.
• Molded Lexan

®

 fan guards and fan blades.

• Drain fitting mounted at 45-degree angle so drain can be run

through the back or bottom of refrigerator.

• Stainless steel screws.
• Motors thermally protected and permanently lubricated.
• Convenient, moisture-proof motor plug.

• Internal junction box for electrical connection.
• UL listed for the United States and Canada; UL classified to

NSF standards.

• Optional corrosion-resistant coated coil available (Model

TAK) for optimum protection in corrosive environments.

Performance/Electrical Data

                  MOTOR DATA

CONNECTIONS (INCHES)

APPROX.

MODEL

  BTUH

 115/1/60

208-230/1/60

COIL

SHIP WT.

TA

10

°

F TD

CFM

QTY

TOTAL FLA

TOTAL FLA

INLET

SUCTION

DRAIN

(LBS.)

10

  1000

 120

  1

0.8

0.4

 1

/

2

FN

       3

/

8

ID

  1

/

2

OD

14

13

  1300

 170

  2

1.6

0.8

 1

/

2

FN

       3

/

8

ID

  1

/

2

OD

17

17

  1700

 210

  2

1.6

0.8

 1

/

2

FN

       3

/

8

ID

  1

/

2

OD

21

23

  2300

 330

  3

2.4

1.2

 1

/

2

FN

       3

/

8

ID

  1

/

2

OD

28

30

  3000

 360

  3

2.4

1.2

 1

/

2

FN

       1

/

2

ID

  1

/

2

OD

33

†43

  4300

 540

  4

3.2

1.6

 1

/

2

FN

       5

/

8

ID

  1

/

2

OD

44

†55

  5500

 650

  5

4.0

2.0

 1

/

2

FN

       5

/

8

ID

  1

/

2

OD

53

 Models 43 and  55 use external equalized expansion valve.

MODEL

DIMENSIONS (INCHES)

TA

  A

 B

 C

  D

   E

 F

 H

J

K

L

M

W

10

14

5

/

8

14

15

/

16

13

1

/

2

10

1

/

2

11

3

/

8

4

1

/

2

8

7

/

8

2

1

/

2

15

/

16

4

3

/

8

16

1

/

2

13

18

5

/

8

14

15

/

16

13

1

/

2

10

1

/

8

10

1

/

4

4

1

/

2

8

3

/

8

9

1

/

2

15

/

16

4

3

/

8

20

1

/

2

17

22

1

/

8

15

15

/

16

14

1

/

2

11

1

/

8

12

4

1

/

2

9

3

/

8

11

1

/

4

15

/

16

4

3

/

8

24

23

29

3

/

4

15

15

/

16

14

1

/

2

13

20

7

/

8

4

1

/

2

10

3

/

4

10

1

/

4

15

/

16

4

3

/

8

31

5

/

8

30

38

1

/

8

15

15

/

16

14

1

/

2

13

29

3

/

4

4

1

/

2

10

3

/

4

9

3

/

4

15

/

16

4

3

/

8

40

43

51

1

/

2

15

15

/

16

14

1

/

2

13

48

3

/

4

4

1

/

2

10

3

/

4

13

1

/

4

15

/

16

4

3

/

8

53

3

/

8

55

51

1

/

2

15

15

/

16

14

1

/

2

13

49

6

3

/

4

10

3

/

4

11

15

/

16

4

3

/

8

53

3

/

8

Dimensional Data

TA  (K)  17  B  E

Vintage

A = 115/1/60

B = 208-230/1/60

TA= Thin Profile

Air Defrost

K = Coated Coil

(Optional)

Size

NOMENCLATURE

Содержание BBL10

Страница 1: ...BulletinCH B 01A January2001 ReplacesCH B 01 Chandler Reach In Unit Coolers...

Страница 2: ...2 Heatcraft Inc 2001...

Страница 3: ...rmally protected and permanently lubricated Optional corrosion resistant coated coil available VAK for optimum protection in corrosive environments UL listed for the United States and Canada UL classi...

Страница 4: ...n Model C High Profile Reach In Unit Cooler Full collar aluminum fins on expanded copper tubes Internal junction box with pigtail leads for electrical connection Motors are thermally protected and per...

Страница 5: ...del BTOK for optimum protection in corrosive environments BTO K MOTOR DATA MODEL BTUH 115 1 60 208 230 1 60 NO 10 T D 15 T D CFM QTY TOTAL FLA TOTAL FLA 09 900 1350 130 1 0 8 0 4 13 1300 1950 240 2 1...

Страница 6: ...rrosive environments Performance Electrical Data MOTOR DATA CONNECTIONS INCHES APPROX MODEL BTUH 115 1 60 208 230 1 60 COIL SHIP WT TA 10 F TD CFM QTY TOTAL FLA TOTAL FLA INLET SUCTION DRAIN LBS 10 10...

Страница 7: ...and Canada UL classified to NSF standards BTUH 10 F TD MOTOR DATA HEATER DATA CONNECTIONS INCHES APPROX MODEL 20 F 10 F 115 1 60 208 230 1 60 115 1 60 208 230 1 60 COIL SHIP WT TL SST SST CFM QTY TOT...

Страница 8: ...ainless steel hardware Coils have full collar aluminum fins on expanded copper tubes Refrigerant connection knockouts provided on both ends of unit Expansion valve mounts inside the unit Motors are th...

Страница 9: ...in salad dressings spiced meats and other food products FEATURES Textured aluminum cabinet PVC coated fan guard Stainless steel hardware Coils have full collar aluminum fins on expanded copper tubes...

Страница 10: ...e Motors are thermally protected and permanently lubricated Optional coated coil available Model UK for optimum protection in corrosive environments All sizes UL component recognized and NSF approved...

Страница 11: ...ded for efficient heat transfer The coils are dehydrated and sealed Textured aluminum cabinet Knockouts are conveniently located for refrigerant lines Screws are hardened stainless steel with a bright...

Страница 12: ...k Place Blvd Stone Mountain GA 30087 770 465 5600 Fax 770 465 5990 Since product improvement is a continuing effort at Chandler we reserve the right to make changes in specifications without notice Vi...

Отзывы: