ChamSys 10Scene 300-054 Скачать руководство пользователя страница 3

Connections 

10Scene wall plates feature a 7 pin push lock cable connector which is wired 
using the below table. 10Scene Wall mounts should be wired before connecting 
to QuickQ Rack/Gateway Interface.   

Pin

 

Name

 

Description

 

Recommended wiring

 

POWER + 

Positive power in/out 

CAT5e Orange pair IN (twisted together 

POWER + 

Positive power in/out 

CAT5e Orange pair OUT (twisted together) 

10Scene H 

10Scene signal High in/out  CAT5e Blue/white wire IN/OUT 

10Scene L 

10Scene signal Low in/out  CAT5e Blue wire IN/OUT 

10Scene 0V  10Scene 0V (NOT USED) 

NOT USED 

POWER - 

Negative power in/out 

CAT5e Brown pair IN (twisted together)  

POWER- 

Negative power in/out 

CAT5e Brown pair OUT (twisted together) 

 

When looking at the rear of the 10Scene Pin 7 is at the 
top and Pin 1 at the bottom.  

 

Pin 7 

 

Pin 1 

 

 

 

  

If daisy chaining, twist 10Scene High IN and the OUT wires together and connect to Pin 3, 

and twist 10Scene Low IN and the OUT wires together and connect to Pin 4. 

  

 

 

 

Содержание 10Scene 300-054

Страница 1: ...ChamSys 10Scene Wall Mount Installation and Configuration Guide Model 300 054 300 055...

Страница 2: ...e is available as the U S fit version 300 054 or EU fit version 300 055 and fits into a standard U S Single Gang or EU Single Gang electrical back box respectively 10Scene uses its own 10Scene protoco...

Страница 3: ...ether 3 10Scene H 10Scene signal High in out CAT5e Blue white wire IN OUT 4 10Scene L 10Scene signal Low in out CAT5e Blue wire IN OUT 5 10Scene 0V 10Scene 0V NOT USED NOT USED 6 POWER Negative power...

Страница 4: ...pair twisted together 2 TRIG IN Trigger input 5V logic or close contact to POWER Not used for 10Scene 3 10Scene H 10Scene signal High CAT5e Blue white wire 4 10Scene L 10Scene signal Low CAT5e Blue wi...

Страница 5: ...a Scene has been stored but is not active when in Red this indicates the Scene is active Buttons can be labelled using the provided paper legends with the 10Scene Wall Mounts 10Scene Programming 10Sce...

Страница 6: ...tee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment of...

Страница 7: ...8023 8666 or email support chamsys co uk WEEE Producer registration number WEE FF5605UX 10Scene Warranty 10Scene Wall Mounts come with a two year parts and labour warranty which covers the device for...