91
PART 6:
REPLACEMENT PARTS
Part 8: SPECIAL BULLETINS
P.O. Box 4146
Winston-Salem, NC 27115
Tel: 336-661-1556
Fax: 336-661-1660
Tel: 800-858-4477
SERVICE BULLETIN
Stemco Thermostat Replacement
Stemco Replaces Fenwall
January 20, 2003
REPLACING FENWAL THERMOSTAT
P/N 100128 WITH STEMCO THERMOSTAT
P/N 109069
For all Navy machines that are purchased with steam heated boosters. This notification is
for the replacement of the thermostat in those boosters. To ensure that the thermostat is
placed properly into the booster tank, please follow the diagram listed below. When replac-
ing the the thermostat use part number 109069.
1. Mark off the measurement of 12 inches from the end of the bulb. This will be at the end
of the 1/2" nut that mounts inside of the tee.
2. Insert the thermostat bulb 12 inches into the booster. Ensure that the bulb is inside one
of the copper water tubes and not coiled up inside of the head. Place plumbers putty on
the 1/2" nut. Tighten down the 1/2" nut inside of the tee.
3. Push the remaining capillary tube to the marking and tighten down the compression nut
so as to lock down the furrell on the capillary. The thermostat replacement is now
complete.
Navy Steam Boosters
12 Inches
12 inches
Содержание USN-10
Страница 1: ...I ...
Страница 3: ...i TECHNICAL PUBLICATION SHEET TECHNICAL PUBLICATION SHEET ...
Страница 4: ...ii TECHNICAL MANUAL VALIDATION CERTIFICATE TECHNICAL MANUAL VALIDATION CERTIFICATE ...
Страница 5: ...iii APPROVAL AND PROCUREMENT RECORD APPROVAL AND PROCUREMENT RECORD ...
Страница 7: ...8 25 10 50 51 U2769 Revised illustration added note for supersession of overflow tube and screen ...
Страница 9: ...vii ...
Страница 16: ...Final Rinse Steam Thermostat Adjustment and Replacement Fuses and Fuse Block Replacement ...
Страница 18: ...xvi TABLE OF CONTENTS This Page Intentionally Left Blank ...
Страница 20: ...Two electrical connections ...
Страница 21: ......
Страница 25: ...7 PART 2 INSTALLATION This Page Intentionally Left Blank ...
Страница 27: ...9 PART 2 INSTALLATION This Page Intentionally Left Blank ...
Страница 28: ...1 The USN 10 undercounter dishwasher does not require a ventilation connection ...
Страница 31: ...13 PART 2 INSTALLATION This Page Intentionally Left Blank ...
Страница 39: ...21 PART 3 OPERATION This Page Intentionally Left Blank ...
Страница 48: ...1 The USN 10 undercounter dishwasher does not require lubrication 4 5 Lubrication Schedules ...
Страница 49: ...31 PART 4 CLEANING AND MAINTENANCE This Page Intentionally Left Blank ...
Страница 68: ...2 1 1 4 3 4 Figure 6 3 Scrap Screen Pump Strainer and Overflow ...
Страница 70: ...52 PART 6 REPLACEMENT PARTS Figure 6 4 Electric Tank Heat Assembly Prior to S N G3599 1 2 3 7 5 8 6 4 9 10 ...
Страница 74: ...56 PART 6 REPLACEMENT PARTS Figure 6 6 Electric Tank Heat Assembly After S N U2769 2 4 5 3 1 6 7 8 ...
Страница 76: ...58 PART 6 REPLACEMENT PARTS Figure 6 7 Steam Tank Heat Assembly After S N U2769 5 2 1 6 8 7 3 4 9 ...
Страница 78: ...60 PART 6 REPLACEMENT PARTS Figure 6 8 Pump and Motor Assembly 3 5 9 6 3 7 3 8 9 10 4 2 3 1 ...
Страница 86: ...68 PART 6 REPLACEMENT PARTS Figure 6 12 Water Solenoid Valve and PRV 1 2 3 4 ...
Страница 88: ...Figure 6 13 Electric Booster Prior to S N G3599 ...
Страница 90: ...72 PART 6 REPLACEMENT PARTS Figure 6 14 Electric Booster After S N G3600 5 1 4 3 2 ...
Страница 97: ...79 PART 6 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 100: ...82 PART 6 REPLACEMENT PARTS Figure 6 18 Dishracks 1 2 ...
Страница 102: ...84 PART 6 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 103: ......
Страница 104: ...86 PART 6 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 105: ...For Machines Built Prior to S N U10063397 For Machines Built Prior to S N U10063397 ...
Страница 108: ...90 PART 6 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...