Undercounter High Temperature
Dishwashing Machine
with Built-in Booster Heater
UH-200b
UH
-200b
U
nderco
U
nter
Due to an ongoing value analysis program at Champion, specification contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 800/263-5798 • Fax: 905/562-4618
Dimensions shown in inches and [millimeters]
Warning
Plumbing and
electrical connections should
be made by qualified personnel
who will observe all the
applicable plumbing, sanitary
and safety codes and the
National Electrical Code.
Field convertible to accept 3 phase power
Plan View
Volume crated:
15 cu. ft./0.42 cu.m.
Shipping weight crated:
215 lbs./97.5 kg.
Utilities
1
Electrical
208-240/60/1; 3 wire plus ground, (See Box).
208-240/60/3; 4 wire plus ground, (See Box).
2
Hot Water
1/2” supply; 140°F/60°C Min. hot water connection for 40°F/22°C rise booster;
110°F/43°C Min. hot water connection for 70°F/39°C rise booster. Incoming supply
pressure must maintain a Flow pressure of 20-22 PSI (Pressure reducing valve, PRV,
supplied by customer or may be purchased unmounted from Champion).
Machine equipped with 3/4” [19] hose connector.
3
Pumped Drain
5/8” [15.9] I.D. flexible reinforced hose, 6 ft. [1829] long.
Max. drain flow 15 US gpm. [12.5 imp gal] Max. drain height 3 ft. [914]
3
2
1
40-1/2"
[1029]
14-3/4"
[375]
Clearance
33-3/4" [857]
1
2
3
24" [610]
25" [635]
CHAMPION
UH200B
4" [102]
15-3/4" [400]
2" [51]
3
2
1
40-1/2"
[1029]
14-3/4"
[375]
Clearance
33-3/4" [857]
1
2
3
24" [610]
25" [635]
CHAMPION
UH200B
4" [102]
15-3/4" [400]
2" [51]
3
2
1
40-1/2"
[1029]
14-3/4"
[375]
Clearance
33-3/4" [857]
1
2
3
24" [610]
25" [635]
CHAMPION
UH200B
4" [102]
15-3/4" [400]
2" [51]
Front View
SPecIFIcAtIonS
Capacities
Cycle time (seconds)
90
Racks per hr. (NSF)
30
Motor horsepower
Wash
1
Water consumption
U.S. Gal./Imperial Gal.
(Max. use) per hr.
28.2/23.2
U.S. Gal./Imperial Gal.
per rack
.9/.75
Temperatures °F/°C
Wash
150/66
Rinse
180/82
Heating
Tank heat, electric, kW
2.0
Electric booster
(kW) required for 40°F/22°C rise)
6
Electric booster
(kW) required for 70°F/39°C rise)
9
Time Cycle in Seconds
Wash
70
Rinse
15
Total cycle
90
Standard 20” x 20” [508 x 508]
Rack Complement
Dish
1
Open
1
UH-200 without booster
750 Watt tank heat
Elec. Specs.
Rated Amps
115/60/1
12
115V
115V
208V
L1
L2
N
G
Note:
Electrical supply service
must be a 3-wire plus ground for
connection shown.
Side View
UH-200B with 40°F/22°C Rise Booster
Elec. Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/1
32
40
40
240/60/1
36
40
40
208/60/3
22
30
30
240/60/3
24
30
30
UH-200B with 70°F/39°C Rise Booster
Elec. Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/1
45
60
60
240/60/1
50
60
60
208/60/3
29
35
35
240/60/3
33
40
40