INSTALLATION
6
Plumbing Connections
CAUTION:
Plumbing connections must comply with local sanitary and plumbing codes.
Water Connections
1.
Connect the hot water supply (60°C/ 140°F Min) to the 1/2" I.D. fill hose. The fill solenoid
valve is equipped with a flow control that will accept water pressures from 172 kPa/25 psi to
665 kPa/95 psi.
2.
Install a manual shut-off valve in the water supply line to accommodate servicing the
machine. The shut-off valve should be the same size or larger than the supply line.
3.
The fill solenoid valve is equipped with a built-in strainer to protect from particles in the
water supply.
Drain Connections
1.
All Models are supplied with a flexible 5/8" I.D. drain hose, which must be connected to a
1-1/2" drain using a wye (Y) fitting.
Detergent
1.
Use a qualified detergent/chemical supplier for your detergent, rinse aid, and chemical
sanitizer needs.
2.
Your machine is supplied with a detergent dispensing pump that is internally wired and
ready for use. Using a liquid detergent, insert the labeled
Detergent
pickup tube into the
detergent container. The pickup tube has a strainer on the end to prevent crystallized
chemical from clogging the supply lines.
3.
The cycle timer located in the main control cabinet is equipped with adjustable cams for the
chemical dispensing pump(s). The cams control the length of time that the pumps operate.
A qualified person may adjust the cam settings if necessary. Refer to the timer chart
diagram(s) at the end of the manual for timer cam locations and factory time settings.
NOTE:
A nonchlorinated detergent is recommended for your dishwasher.
Rinse Aid
1.
An optional rinse aid pump may be supplied for all models. Using a liquid rinse aid, insert
the labeled
Rinse Aid
pickup tube into the rinse aid container.
Chemical Sanitizer
1.
Model UTL is supplied with an internally wired chemical sanitizer dispensing pump. Using
a 5.25% or 8.4% sodium hypochlorite solution, insert the labeled
Chemical Sanitizer
pickup
tube into the chemical sanitizer container.
2.
Contact your chemical supplier for adjustment of the chemical sanitizer.
!
Содержание TUW
Страница 20: ...15 REPLACEMENT PARTS REPLACEMENT PARTS ...
Страница 21: ...16 REPLACEMENT PARTS 14 14 14 13 12 00001 11 8 7 6 5 9 4 3 2 1 10 Figure 1 Track and Panel Assembly ...
Страница 23: ...18 REPLACEMENT PARTS 1 2 3 5 7 8 9 10 11 12 13 14 15 16 17 18 15 1 6 4 1 00020 Figure 2 Door Switch Assembly ...
Страница 27: ...22 REPLACEMENT PARTS TANK BOTTOM 12 14 13 11 10 9 8 7 6 5 4 2 3 1 00005 Figure 4 Pump Assembly ...
Страница 46: ...41 ELECTRICAL SCHEMATICS ELECTRICAL SCHEMATICS ...