18
Troubleshooting
SYMPTOM
CAUSE
SOLUTION
Motor does not start.
Body is not properly assembled to hub.
Check assembly.
Magnet in body flange is missing.
Replace magnet.
ON/OFF Switch is off.
Turn on switch.
Power supply is bad.
Check plug and circuit breaker.
Proximity switch is bad.
Replace proximity switch.
ON/OFF Switch is bad.
Replace ON/OFF switch.
Juicer motor bad.
Replace motor.
Motor stalls.
Feeding too much material and/or too fast.
Feed material more slowly.
Auger worn.
Replace auger.
Restrictor worn.
Replace restrictor.
Juice/pulp slinging from restrictor.
Deflector not installed.
Install deflector.
Excessive or unusual noise.
Improper assembly.
Re-assemble.
Part damage.
Replace damaged parts.
Excessive heat in juice or pulp.
Feeding too much material and/or too fast.
Feed material more slowly.
Restrictor plugged.
Remove restrictor, clear blockage and replace.
Auger worn.
Replace auger.
Restrictor worn.
Replace restrictor.
Leakage of juice at flange of body.
O-ring missing.
Install o-ring.
O-ring damaged or worn.
Replace o-ring.
Body damaged.
Replace body.
Material backs up in feeding tube.
Feeding too much material and/or too fast.
If operating at a low speed, increase speed.
Feed a clump or two of pulp to clear chamber.
Restrictor plugged.
Turn off power, remove restrictor, turn on
power; chamber will clear. Turn off power.
Clean and replace restrictor. Resume.
Low Yield
Material being juiced is dry.
Replace with fresh material.
Restrictor is missing.
Install restrictor.
Nature of material being juiced.
Re-feed material.