Volume crated:
156 cu. ft.
Shipping weight crated:
900 lbs.
Plumbing Notes:
Because of the variation
in house-supplied steam and water pressures,
steam and water pressure regulating valves
(PRVs) may be needed. (Water PRV is standard
on machines with booster.) The PRVs can either
be purchased from Champion or obtained
locally.
Venting Notes:
Fabricated duct size:
3-7/8” x 15-7/8” (Outside dimensions)
Warning:
Plumbing and electrical connections
should be made by qualified personnel who will
observe all the applicable plumbing, sanitary, safety
codes and the National Electrical Code.
Note:
Water Hammer Arrestor (meeting ASSE-1010
standard or equivalent) to be supplied
(by others) in common water supply line at service
connection.
Machine only
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
120
150
150
240/60/1
105
150
150
208/60/3
74
100
100
240/60/3
65
90
90
480/60/3
33
45
45
575/60/3
25
35
35
TABle A - Machine Connection
Machine and steam built-in booster
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
42
60
60
240/60/1
37
50
50
208/60/3
29
40
40
240/60/3
26
35
35
480/60/3
12
15
15
575/60/3
10
15
15
TABle B - Machine & Booster Connection
70°F/39°C Rise – 22 kW
Machine and Electric built-in booster
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
226
300
300
240/60/1
197
250
250
208/60/3
136
175
175
240/60/3
118
150
150
480/60/3
60
80
80
575/60/3
47
60
60
40°F/22°C Rise – 12 kW
Machine and Electric built-in booster
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
178
225
225
240/60/1
155
200
200
208/60/3
108
150
150
240/60/3
94
125
125
480/60/3
47
60
60
575/60/3
37
50
50
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com
utilities
1
Electrical Connection
A
Machine Only (see Table A)
Machine & Booster (see Table B)
2
Hot Water
3/4” NPT 180°F/82°C min. hot water
connection. (Machine without booster.)
3/4” NPT 140°F/60°C min. hot water
connection. (40°F/34°C rise booster)
3/4” NPT 110°F/49°C min. hot water
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
3
Drain
1-1/2” NPT machine connection.
Maximum flow 15 gpm.
4
Steam
A
3/4” NPT machine connection.
Flow pressure 15-30 PSI. (Steam coil)
B
3/4” NPT machine connection.
Flow pressure 15-30 PSI.
(Steam injector)
5
Condensate
(no back pressure)
1/2” NPT machine return to boiler
6
Vents
A
Load end: 200 CFM @ 1/4” S.P.
B
Unload end: 400 CFM @ 1/4” S.P.
(With blower-dryer increase room
ventilation by 600 CFM.)
44” Single Tank with 36” Heavy Duty Prewash
High Temperature Rack
Conveyor Dishwashing Machine with
Dual Stage Rinse
Model 80 dRHdPW
SPeCIFICATIoNS
Capacity
Racks per hr. (NSF rated)
208
Wash tank (US gal.)
21
Conveyor speed (ft/min.)
5.8
Motor Horsepower
Drive
1/6
Prewash
1
Wash
2
DualRInse
1/10
Water Consumption
US Gal. per hr.
(max. use)
112
US Gal. per rack
.54
Heating
Wash Tank, electric (kW)
15
DualRinse Tank electric (kW)
3
Tank heat, steam (lbs/hr.
required at 15 PSI flow pressure) 75
Electric booster (built-in)
(kW supplied for 40°F rise)
12
Electric booster
(kW supplied for 70°F rise) 22
Steam booster (lbs./hr.
required for 40°F rise)
60
Steam booster (lbs./hr.
required for 70°F rise)
106
Venting
Load end (minimum CFM)
200
Unload end (minimum CFM) 400
Standard 20” x 20”
rack complement
Peg
2
Flat
1