Volume crated:  

152 cu. ft.

Shipping weight crated:  

800 lbs.

Dimensions shown in inches

Warning: 

Plumbing and electrical connections should be made by qualified personnel who will 

observe all the applicable plumbing, sanitary, safety codes and the National Electrical Code.

Note: 

Water Hammer Arrestor (meeting ASSE-1010 standard or equivalent) to be supplied  

(by others) in common water supply line at service connection.

Plumbing Notes:

 Because of the variation in house-supplied steam and water pressures, steam and 

water pressure regulating valves (PRVs) may be needed. (Water PRV is standard on machines with booster.) 

The PRVs can either be purchased from Champion or obtained locally.

Venting Notes: 

Fabricated duct size: 3-7/8” x 15-7/8” (Outside dimensions) 

 Machine only

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/1 

120 

150 

150

  240/60/1  

105 

150 

150

  208/60/3  

74 

100 

100

  240/60/3  

65 

90 

90

  480/60/3  

33 

45 

45

  575/60/3  

25 

35 

35

Table a - Machine connecTion

 Machine and steam built-in booster

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/1 

42 

60 

60

  240/60/1  

37 

50 

50

  208/60/3  

29 

40 

40 

  240/60/3  

26 

35 

35

  480/60/3  

12 

15 

15

  575/60/3  

10 

15 

15

Table b - Machine & boosTer connecTion

 70°F/39°C Rise –  16 kW 

  Machine and Electric built-in booster 

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/1  

197 

250 

250

  240/60/1  

172 

225 

225

  208/60/3  

119 

150 

150

  240/60/3 

103 

125 

125

  480/60/3  

52 

70 

70

  575/60/3  

41 

50 

50

Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.

Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 

2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618

Utilities

 

1

  Electrical Connection

a

  Machine only (see Table A) 

b

  Machine & booster (see Table B)

 

2

  Hot Water

3/4” NPT 180°F/82°C min. hot water 

connection. (Machine without booster.) 
3/4” NPT 140°F/60°C min. hot water 

connection. (40°F/22°C rise booster) 
3/4” NPT 110°F/49°C min. hot water 

connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.

 

3

  Drain 

1-1/2” NPT machine connection.  

Maximum flow 15 gpm.

 

4

  Steam 

a

  3/4” NPT machine connection.  

  Flow pressure 15-30 PSI. (Steam coil)

b

  3/4” NPT machine connection.  

  Flow pressure 15-30 PSI.  

  (Steam injector)

 

5

  Condensate 

(no back pressure)

1/2” NPT machine return to boiler

  6

  Vents

a

  Load end: 200 CFM @ 1/4” S.P.

b

  Unload end: 400 CFM @ 1/4” S.P.  

  (With blower-dryer increase room    

ventilation by 600 CFM.)

Model 66 drWsPW 

44” Single Tank Water Saver with 22” Prewash

High Temperature Rack Conveyor  

Dishwashing Machine with

Dual Stage Rinse

44” Single Tank Water Saver with 22” Prewash

High Temperature Rack Conveyor  

Dishwashing Machine with

Dual Stage Rinse

44” Single Tank Water Saver with 22” Prewash

High Temperature Rack Conveyor  

Dishwashing Machine with

Dual Stage Rinse

Model 66 drWsPW 

Model 66 drWsPW 

sPeciFicaTions

Capacity

 

Racks per hr. (NSF rated) 

  148

Wash tank (US gal.) 

 

21

Conveyor speed (ft/min.) 

 

4.1

Motor Horsepower 

  Drive 

 

1/6 

Wash 

 

Prewash 

 

Dual Rinse 

  1/10

Water Consumption

US Gal. per hr.  

(max. use) 

 

80

US Gal. per rack 

 

.54

Heating

Wash Tank, electric (kW) 

 

15

DualRinse Tank electric (kW)   

3.3 

Tank heat, steam (lbs/hr. 

  required at 15 PSI flow pressure) 

75

Electric booster (built-in) 

(kW supplied for 40°F rise)     

10

Electric booster  

(kW supplied for 70°F rise)   

16

Steam booster (lbs./hr.  

required for 40°F rise) 

 

50

Steam booster (lbs./hr.  

required for 70°F rise) 

 

 80

Venting 

Load end (minimum CFM) 

  200

Unload end (minimum CFM)    400

Standard 20” x 20”  

rack complement

Peg   

 

2

Flat   

 

1

 40°F/22°C Rise –  10 kW 

 Machine and Electric built-in booster 

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/1  

168 

225 

225

  240/60/1  

147 

200 

200

  208/60/3  

102 

125 

125

  240/60/3  

89 

110 

110

  480/60/3  

45 

60 

60

  575/60/3  

37 

45 

45

Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com

2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618

Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com

2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618

Содержание Model 66 DRWSPW

Страница 1: ...etely interplumbed controls are interwired Steam 40 F 70 F rise Electric 10 kW 40 F rise built in only Electric 16 kW 70 F rise built in only Cantilever sideloader with or without hood for 90 load operation Extended pawl bar extended drive unit for use with load tabling 90 Motorized rack curve unload 180 Motorized rack curve unload Racks peg or flat racks specify type Roller conveyor table mobile ...

Страница 2: ...etely interplumbed controls are interwired Steam 40 F 70 F rise Electric 10 kW 40 F rise built in only Electric 16 kW 70 F rise built in only Cantilever sideloader with or without hood for 90 load operation Extended pawl bar extended drive unit for use with load tabling 90 Motorized rack curve unload 180 Motorized rack curve unload Racks peg or flat racks specify type Roller conveyor table mobile ...

Страница 3: ... NPT 140 F 60 C min hot water connection 40 F 22 C rise booster 3 4 NPT 110 F 49 C min hot water connection 70 F 39 C rise booster Flow pressure 20 22 psi 3 Drain 1 1 2 NPT machine connection Maximum flow 15 gpm 4 Steam A 3 4 NPT machine connection Flow pressure 15 30 psi Steam coil B 3 4 NPT machine connection Flow pressure 15 30 psi Steam injector 5 Condensate no back pressure 1 2 NPT machine re...

Страница 4: ... NPT 140 F 60 C min hot water connection 40 F 22 C rise booster 3 4 NPT 110 F 49 C min hot water connection 70 F 39 C rise booster Flow pressure 20 22 psi 3 Drain 1 1 2 NPT machine connection Maximum flow 15 gpm 4 Steam A 3 4 NPT machine connection Flow pressure 15 30 psi Steam coil B 3 4 NPT machine connection Flow pressure 15 30 psi Steam injector 5 Condensate no back pressure 1 2 NPT machine re...

Страница 5: ... NPT 140 F 60 C min hot water connection 40 F 22 C rise booster 3 4 NPT 110 F 49 C min hot water connection 70 F 39 C rise booster Flow pressure 20 22 psi 3 Drain 1 1 2 NPT machine connection Maximum flow 15 gpm 4 Steam A 3 4 NPT machine connection Flow pressure 15 30 psi Steam coil B 3 4 NPT machine connection Flow pressure 15 30 psi Steam injector 5 Condensate no back pressure 1 2 NPT machine re...

Страница 6: ...etely interplumbed controls are interwired Steam 40 F 70 F rise Electric 10 kW 40 F rise built in only Electric 16 kW 70 F rise built in only Cantilever sideloader with or without hood for 90 load operation Extended pawl bar extended drive unit for use with load tabling 90 Motorized rack curve unload 180 Motorized rack curve unload Racks peg or flat racks specify type Roller conveyor table mobile ...

Отзывы: