104
Time Cycle Chart
CUSTOMER TO SUPPLY RATED VOLTAGE/PHASE/Hz,
AS SPECIFIED PER ORDER,TO DISCONNECT SWITCH.
ALL POWER SUPPLIED TO EACH CONNECTION POINT
MUST COMPLY WITH ALL LOCAL ELECTRIC CODES.
BY
DATE
DESCRIPTION
REV.
B
REV.
The Dishwashing Machine Specialists
SCALE
DR.BY
DATE
SHEET
OF
REV.
DESCRIPTION
DATE
BY
DH5000T
TIME CYCLES
114470-17
A
J.MCALLISTER
7MAR12
1
1
100
100
100
100
100
100
100
30
0
10
20
40
60
50
70
80
90
30
30
30
0
10
20
0
10
20
0
10
20
40
60
50
40
60
50
70
80
90
70
80
90
40
60
50
70
80
90
30
10
0
20
40
50
60
80
70
90
30
30
0
10
20
0
10
20
40
60
50
70
80
90
40
60
50
70
80
90
110
130
120
150
140
160
200
180
170
190
220
210
230
110
130
120
110
130
120
150
140
160
150
140
160
110
130
120
150
140
160
200
200
180
170
190
180
170
190
220
210
230
220
210
230
200
180
170
190
220
210
230
270
250
240
260
290
280
300
340
320
310
330
270
270
250
240
260
250
240
260
290
280
300
290
280
300
270
250
240
260
290
280
300
340
340
320
310
330
320
310
330
340
320
310
330
110
120
130
150
140
160
200
170
180
190
220
210
230
110
130
120
150
140
160
110
130
120
150
140
160
200
170
180
190
220
210
230
200
180
170
190
220
210
230
270
250
240
260
290
280
300
340
320
310
330
270
250
240
240
260
290
280
300
270
250
240
260
290
280
300
340
320
310
330
340
320
310
330
330
310
320
340
300
280
290
260
240
250
270
230
210
220
190
180
170
200
160
140
150
130
120
110
90
80
70
60
50
40
20
10
0
30
100
DH5000T - MODE C - TIME CYCLES 3 AND 4
360
350
360
350
360
350
360
350
DRAWING REPRESENTS ONLY THE STRUCTURE OF TIME CYCLES 3 AND 4.
FOR CYCLES 1 AND 2 SEE DWG# 114470 SHEET 9
CYCLE 3
CYCLE 4
CYCLE 4
CYCLE 3
A
CHANGED RINSE AND DWELL CYCLE TIMES
19SEP12 JAM
SANITARY DWELL
RINSE
DWELL
INITIAL STATE:
POWER ON
DOORS OPEN
TANK FULL
WASH
214
NOTES:
TRIGGERING EVENT:
CYCLE SWITCH IN POSITION 1, 2, 3 OR
4
"CYCLE SWITCH" STATE IS IGNORED
DURING CYCLE, IT IS READ AT BEGINNING
AT THE CYCLE AND PROPER CYCLE TIME
STRUCTURE APPLIED.
4 MINUTE CYCLE (240 SECONDS TOTAL)
CONSISTING OF: 214 SECOND WASH,
1 SECOND DWELL,
15 SECOND RINSE,
AND 10 SECOND DWELL.
INPUTS
SOLID LINE INDICATES SWITCH
CLOSURE
OUTPUT
SOLID LINE INDICATES 120VAC
COMING OUT OF THE OUTPUT
TERMINAL
WASH TIMES:
1 MINUTE =
∞
90 SECONDS = 0
Ω
4 MINUTE = 4.7K
Ω
6 MINUTE = 15K
Ω
JUMPER SETTINGS:
JB1 = OPEN
JB2 = CLOSED
JB3 = OPEN
SANITARY DWELL
RINSE
DWELL
WASH
215
230
240
334
335
350
360
6 MINUTE CYCLE (360 SECONDS TOTAL)
CONSISTING OF: 334 SECOND WASH,
1 SECOND DWELL,
15 SECOND RINSE,
AND 10 SECOND DWELL.
214
215
334
335
Содержание DH5000T Series
Страница 17: ...9 Blank Page This Page Intentionally Left Blank ...
Страница 40: ...32 Wash Pump Motor Assembly 12 11 10 14 13 9 8 7 6 5 4 1 2 3 ...
Страница 46: ...38 Fill Piping Assembly with Booster Condensate Removal Option Model Only 2 2 7 6 5 9 1 1 7 8 4 3 6 9 ...
Страница 48: ...40 Booster Assembly All Models and Options 1 2 2 3 4 3 5 8 15 9 10 11 13 12 12 13 14 7 6 ...
Страница 50: ...42 Control Panel Assembly 2 3 6 7 8 5 1 4 9 10 ...
Страница 58: ...50 Wash and Rinse Spray Arm Assemblies 1 2 5 6 3 4 1 8 2 7 6 7 5 4 3 ...
Страница 62: ...54 Track and Panel Assemblies 9 4 3 6 1 1 5 10 8 7 2 11 12 13 13 14 15 ...
Страница 74: ...66 Drain Water Tempering Assembly 1 2 3 4 3 5 5 6 7 8 9 10 11 12 14 13 15 ...
Страница 76: ...68 Dish Racks Line Strainer PRV 1 2 3 4 ...
Страница 108: ...100 Blank Page This Page Intentionally Left Blank ...
Страница 110: ...102 Blank Page This Page Intentionally Left Blank ...
Страница 113: ...105 Standard Model DH5000T Electrical Schematic ...
Страница 114: ...106 Direct Vent Option Model and Condensate Removal Option Model DH5000T Electrical Schematic ...