Connecting Electrical Loads

1 .  Let the engine stabilize and warm up for a few 

minutes after starting

2 .  Plug in and turn on the desired 120 Volt AC single 

phase, 60 Hz electrical loads .

 

– DO NOT connect 3-phase loads to the generator .

 

– DO NOT connect 50 Hz loads to the generator .

 

– DO NOT overload the generator .

Connecting a generator to your electric utility 
company’s power lines or to another power source 
may be against the law . In addition this action, 
if done incorrectly, could damage your generator 
and appliances and could cause serious injury or 
even death to you or a utility worker who may be 
working on nearby power lines . If you plan to run a 
portable electric generator during an outage, please 
notify your electric utility company immediately 
and remember to plug your appliances directly 
into the generator . Do not plug the generator into 
any electric outlet in your home . Doing so could 
create a connection to the utility company power 
lines . You are responsible for ensuring that your 
generator’s electricity does not feed back into the 
electric utility power lines .
If the generator will be connected to a building 
electrical system, consult your local utility company 
or a qualified electrician . Connections must isolate 
generator power from utility power and must comply 
with all applicable laws and codes .

NOTE

OPERATION

do Not Overload Generator

Capacity

Follow these simple steps to calculate the running and 
starting watts necessary for your purposes . 
1 .  Select the electrical devices you plan on running at 

the same time .

2 .  Total the running watts of these items . This is 

the amount of power you need to keep your items 
running .

3 .  Identify the highest starting wattage of all devices 

identified in step 1 . Add this number to the number 
calculated in step 2 . Surge wattage is the extra 
burst of power needed to start some electric driven 
equipment . Following the steps listed under “Power 
Management” will guarantee that only one device will 
be starting at a time .

Power Management

Use the following formula to convert voltage and 
amperage to watts:

Volts x Amps = Watts

To prolong the life of your generator and attached 
devices, follow these steps to add electrical load:
1 .  Start the generator with no electrical load attached
2 .  Allow the engine to run for several minutes to stabilize .
3 .  Plug in and turn on the first item . It is best to attach 

the item with the largest load first .

4 .  Allow the engine to stabilize .
5 .  Plug in and turn on the next item .
6 .  Allow the engine to stabilize .
7 .  Repeat steps 5-6 for each additional item .

Never exceed the specified capacity when adding 
loads to the generator .

NOTE

Stopping the Engine

1 .  Turn off and unplug all electrical loads . Never start 

or stop the generator with electrical devices plugged 
in or turned on .

2 .  Let the generator run at no-load for several minutes 

to stabilize internal temperatures of the engine and 
generator .

3 .  Press the ignition switch to the “OFF” position .
4 .  Turn the Fuel Valve to the “OFF” position .

Important:

 If the generator will be moved or stored 

turn the Fuel Valve to the “OFF“ position and ensure 
the Ignition Switch on the Power Panel is in the “OFF“ 
position .

Содержание B46517

Страница 1: ...oad Santa Fe Springs CA 90670 USA 1 877 338 0999 www championpowerequipment com PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV B...

Страница 2: ...he store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Car...

Страница 3: ...Management 11 Wattage Reference Chart 12 Maintenance and Storage 13 Engine Maintenance 13 Oil 13 Spark Plugs 13 Air Filter 13 Spark Arrester 14 Cleaning 14 Adjustments 14 Maintenance Schedule 14 Gene...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...y hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided...

Страница 6: ...and remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught Generator produces powerful voltage DO NOT touch bar...

Страница 7: ...pull hand and arm towards the engine faster than you can let go Unintentional startup can result in entanglement traumatic amputation or laceration Broken bones fractures bruises or sprains could resu...

Страница 8: ...the engine 3 Fuel Valve Turn this valve to the ON position to supply fuel to the engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used to star...

Страница 9: ...used to supply electrical power for the operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 5 120 Volt AC 30 Amp Recreational Vehicle RV Receptacle NEMA TT 30R May be used to supply el...

Страница 10: ...8 Wheel 2 Flange Bolt M10x105 for Wheel 2 Bushing 2 Flat Washer 10 2 Nut M10 2 Handle 1 Flange Bolt M8x45 for Handle 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Nut M8 4 Sp...

Страница 11: ...and oil tip the generator on it s side 2 Slide the M10x105 wheel bolt through the washer sleeve and wheel 3 Slide the bolt through the mount point on the frame 4 Fasten securely with the M10 nut 5 Rep...

Страница 12: ...to the tank DO NOT overfill Allow approximately inch of space for fuel expansion 6 Screw on the fuel cap and wipe away any spilled fuel Use regular unleaded gasoline with a minimum octane rating of 85...

Страница 13: ...to protect sensitive electronic equipment 1 Install UL1449 CSA listed plug in surge suppressors on the outlets feeding your sensitive equipment Surge suppressors come in single or multi outlet styles...

Страница 14: ...y for your purposes 1 Select the electrical devices you plan on running at the same time 2 Total the running watts of these items This is the amount of power you need to keep your items running 3 Iden...

Страница 15: ...Electric Range One Element 1500 Electric Skillet 1250 Coffee Maker 1500 Clothes Washer 1200 Entertainment CD DVD Player VCR 100 Stereo Receiver 450 Television 27 500 PC with 15 Monitor 800 Job Site B...

Страница 16: ...clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove the spark plug...

Страница 17: ...end of the spark arrester to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if it i...

Страница 18: ...tion 4 Be sure all appliances are disconnected from the generator Start the engine and let it run until the fuel in the line and the carburator is consumed and the engine dies 5 Add a fuel stabilizer...

Страница 19: ...Use regular unleaded gasoline with a minimum octane rating of 85 and an ethanol content of less than 10 by volume Generator Specifications Rated Wattage 3500 Watts Starting Wattage 4000 Watts AC Load...

Страница 20: ...17 REV B46517 20110721 ENGLISH B46517 Specifications Parts Diagram...

Страница 21: ...42 GB848 8 Washer 8 2 43 GB7244 8 Locking Washer 8 2 44 GB6175 M8 Nut M8 2 45 ST168FD 1100000 G Muffler 1 46 ST188FD 1180121 Spark Arrester Assembly 1 47 ST188FD 1100010 88 Spark Arrester Cover 1 Par...

Страница 22: ...19 REV B46517 20110721 ENGLISH B46517 Specifications Engine Parts Diagram...

Страница 23: ...rm Bolt 1 47 GB5789 FB6 25 Flange Bolt M6 25 2 48 ST160F 1123000 G Ignition Coil 1 49 152FMD 1001007 Dowel Pin 10x16 2 50 GB5789 FB8 55 Flange Bolt M8 55 4 Part Number Description Qty 51 ST168FD 10902...

Страница 24: ...21 REV B46517 20110721 ENGLISH B46517 Wiring Diagram Specifications...

Страница 25: ...se to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient vent...

Страница 26: ...or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any el...

Страница 27: ...visions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be repaired or replaced by CPE OWNER WARRANTY RESPONSI...

Страница 28: ...anted for the ECS Warranty Period A statement in such written instructions to the effect of repair or replace as necessary shall not reduce the ECS Warranty Period Any such part repaired or replaced u...

Страница 29: ...scellaneous Parts Tubing Fittings Seals Gaskets and Clamps associated with these listed systems TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along w...

Отзывы: