84” Two Tank

High-Temperature

Rack Conveyor Dishwashing Machine

Model 84 

84” Two Tank

High-Temperature

Rack Conveyor Dishwashing Machine

Model 84 

84” Two Tank

High-Temperature

Rack Conveyor Dishwashing Machine

Model 84 

Volume crated:  

130 cu. ft.

Shipping weight crated:  

850 lbs.

Dimensions shown in inches

Warning: 

Plumbing and electrical connections should be made by qualified personnel who will 

observe all the applicable plumbing, sanitary, safety codes and the National Electrical Code.

Note: 

Water Hammer Arrestor (meeting ASSE-1010 standard or equivalent) to be supplied (by 

others) in common water supply line at service connection.

Plumbing Notes:

 Because of the variation in house-supplied steam and water pressures, steam 

and water pressure regulating valves (PRVs) may be needed. (Water PRV is standard on machines with 

booster.) The PRVs can either be purchased from Champion or obtained locally.

Venting Notes: 

Fabricated duct size: 3-7/8” x 15-7/8” (Outside dimensions) 

 Machine only

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/1 

162 

200 

200

  240/60/1  

142 

175 

175

  208/60/3  

90 

110 

110

  240/60/3  

80 

100 

100

  480/60/3  

40 

50 

50

  575/60/3  

31 

40 

40

Table a - Machine connecTion

 Machine and steam built-in booster

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/1 

32 

40 

40

  240/60/1  

29 

40 

40 

  208/60/3  

15 

20 

20

  240/60/3  

14 

20 

20

  480/60/3  

15 

15

Table b - boosTer connecTion

Utilities

 

1

  Electrical

a

  Machine connection (see Table A) 

b

  Booster connection (see Table B)

 

2

  Hot Water

3/4” NPT 180°F/82°C min. hot water 

connection. (Machine without booster.) 
3/4” NPT 140°F/60°C min. hot water 

connection. (40°F/22°C rise booster) 
3/4” NPT 110°F/49°C min. hot water 

connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.

 

3

  Drain 

1-1/2” NPT machine connection.  

Maximum flow 15 gpm.

 

4

  Steam 

a

  3/4” NPT machine connection.  

  Flow pressure 15-30 PSI. (Steam coil)

b

  3/4” NPT machine connection.  

  Flow pressure 15-30 PSI. (Steam    

injector)

 

5

  Condensate 

(no back pressure)

1/2” NPT machine return to boiler

  6

  Vents

a

  Load end: 200 CFM @ 1/4” S.P.

b

  Unload end: 400 CFM @ 1/4” S.P.  

  (With blower-dryer increase room    

ventilation by 600 CFM.)

sPeciFicaTions

Capacity 

Racks per hr. (NSF rated) 

356

Wash tank (US gal.) 

21

Conveyor speed (ft/min.) 

9.9

Motor Horsepower 

Drive  

1/6

Wash 3

Rinse 3

Water Consumption

US Gal. per hr. (max. use) 

131

US Gal. per rack 

.37

Heating

Tank Heat, electric (kW) 

25

Tank heat, steam  

(lbs/hr. required at  

15 PSI flow pressure) 

75

Electric booster (built-in) 

(kW supplied for 40°F rise) 

15

Electric booster  

(kW supplied for 70°F rise) 

24

Steam booster (lbs./hr.  

required for 40°F rise) 

75

Steam booster (lbs./hr.  

required for 70°F rise) 

120

Venting

Load end (minimum CFM) 

200

Unload end (minimum CFM)  400

Standard 20” x 20”  

rack complement

Peg   

2

Flat   

1

 40°F/22°C Rise – 15kW 

  Electric built-in booster (booster only)

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/3  

42 

50 

50

  240/60/3 

36 

45 

45

  480/60/3  

18 

25 

25

  575/60/3  

15 

20 

20

 70°F/39°C Rise – 24kW 

  Electric built-in booster (booster only)

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/3  

67 

80 

80

  240/60/3 

58 

70 

70

  480/60/3  

29 

35 

35

  575/60/3  

24 

30 

30

Содержание 84

Страница 1: ...njector hot water coil Blower dryer with 60 hood table legs and cradle assembly Booster Heaters completely interplumbed controls are interwired Steam 40 F 70 F rise Electric 15 kW 40 F rise only built in 3 phase only Electric 24 kW 70 F max rise 3 phase only Cantilever sideloader with or without hood for 90 load operation Extended pawl bar extended drive unit for use with load tabling 90 Motorized...

Страница 2: ...njector hot water coil Blower dryer with 60 hood table legs and cradle assembly Booster Heaters completely interplumbed controls are interwired Steam 40 F 70 F rise Electric 15 kW 40 F rise only built in 3 phase only Electric 24 kW 70 F max rise 3 phase only Cantilever sideloader with or without hood for 90 load operation Extended pawl bar extended drive unit for use with load tabling 90 Motorized...

Страница 3: ...njector hot water coil Blower dryer with 60 hood table legs and cradle assembly Booster Heaters completely interplumbed controls are interwired Steam 40 F 70 F rise Electric 15 kW 40 F rise only built in 3 phase only Electric 24 kW 70 F max rise 3 phase only Cantilever sideloader with or without hood for 90 load operation Extended pawl bar extended drive unit for use with load tabling 90 Motorized...

Страница 4: ...10 110 240 60 3 80 100 100 480 60 3 40 50 50 575 60 3 31 40 40 TableA MachineConnection Machine and steam built in booster Minimum Maximum Supply Ckt Overcurrent Elec Rated Conductor Protective Specs Amps Ampacity Device 208 60 1 32 40 40 240 60 1 29 40 40 208 60 3 15 20 20 240 60 3 14 20 20 480 60 3 7 15 15 TableB BoosterConnection Utilities 1 Electrical A Machine connection see Table A B Booster...

Страница 5: ...10 110 240 60 3 80 100 100 480 60 3 40 50 50 575 60 3 31 40 40 TableA MachineConnection Machine and steam built in booster Minimum Maximum Supply Ckt Overcurrent Elec Rated Conductor Protective Specs Amps Ampacity Device 208 60 1 32 40 40 240 60 1 29 40 40 208 60 3 15 20 20 240 60 3 14 20 20 480 60 3 7 15 15 TableB BoosterConnection Utilities 1 Electrical A Machine connection see Table A B Booster...

Страница 6: ...10 110 240 60 3 80 100 100 480 60 3 40 50 50 575 60 3 31 40 40 TableA MachineConnection Machine and steam built in booster Minimum Maximum Supply Ckt Overcurrent Elec Rated Conductor Protective Specs Amps Ampacity Device 208 60 1 32 40 40 240 60 1 29 40 40 208 60 3 15 20 20 240 60 3 14 20 20 480 60 3 7 15 15 TableB BoosterConnection Utilities 1 Electrical A Machine connection see Table A B Booster...

Отзывы: