Volume crated:
130 cu. ft.
Shipping weight crated:
865 lbs.
Dimensions shown in inches
Warning:
Plumbing and electrical connections
should be made by qualified personnel who will
observe all the applicable plumbing, sanitary,
safety codes and the National Electrical Code.
Note:
Water Hammer Arrestor (meeting ASSE-
1010 standard or equivalent) to be supplied (by
others) in common water supply line at service
connection.
Plumbing Notes:
Because of the variation
in house-supplied steam and water pressures,
steam and water pressure regulating valves
(PRVs) may be needed. (Water PRV is standard on
machines with booster.) The
PRVs can either be purchased from
Champion or obtained locally.
Venting Notes:
Fabricated duct size:
3-7/8” x 15-7/8” (Outside dimensions)
Machine only
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
162
200
200
240/60/1
142
175
175
208/60/3
90
110
110
240/60/3
80
100
100
480/60/3
40
50
50
575/60/3
31
40
40
TABle A - MACHINe CoNNeCTIoN
Machine and steam built-in booster
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
32
40
40
240/60/1
29
40
40
208/60/3
15
20
20
240/60/3
14
20
20
480/60/3
7
15
15
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com
utilities
1
Electrical
A
Machine connection (see Table A)
B
Booster connection (see Table B)
2
Hot Water
3/4” NPT 180°F/82°C min. hot water
connection. (Machine without booster.)
3/4” NPT 140°F/60°C min. hot water
connection. (40°F/22°C rise booster)
3/4” NPT 120°F/49°C min. hot water
connection. (60°F/34°C rise booster)
3/4” NPT 110°F/49°C min. hot water
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
3
Drain
1-1/2” NPT machine connection.
Maximum flow 15 gpm.
4
Steam
A
3/4” NPT machine connection.
Flow pressure 15-30 PSI. (Steam coil)
B
3/4” NPT machine connection.
Flow pressure 15-30 PSI.
(Steam injector)
5
Condensate
(no back pressure)
1/2” NPT machine return to boiler
6
Vents
A
Load end: 200 CFM @ 1/4” S.P.
B
Unload end: 400 CFM @ 1/4” S.P.
(With blower-dryer increase room
ventilation by 600 CFM.)
64” Two Tank
High-Temperature
Rack Conveyor Dishwashing Machine
Model 64
SPeCIFICATIoNS
Capacity
Racks per hr. (NSF rated)
277
Wash tank (US gal.)
21
Conveyor speed (ft/min.)
7.7
Motor Horsepower
Drive
1/6
Wash 2
Rinse 2
Water Consumption
US Gal. per hr. (max. use)
124
US Gal. per rack
.45
Heating
Tank Heat, electric (kW)
25
Tank heat, steam
(lbs/hr. required at
15 PSI flow pressure)
75
Electric booster (built-in)
(kw supplied for 40°F rise)
15
Electric booster (built-in)
(kW supplied for 70°F rise)
24
Steam booster (lbs./hr.
required for 40°F rise)
120
Steam booster (lbs./hr.
required for 70°F rise)
205
Venting
Load end (minimum CFM)
200
Unload end (minimum CFM)
400
Standard 20” x 20”
rack complement
Peg
2
Flat
1
TABle B - BooSTeR CoNNeCTIoN
40°F/22°C Rise – 15kW
Electric built-in booster (booster only)
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
42
50
50
240/60/3
36
45
45
480/60/3
18
25
25
575/60/3
15
20
20
70°F/39°C Rise – 24kW
Electric built-in booster (booster only)
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
67
80
80
240/60/3
58
70
70
480/60/3
29
35
35
575/60/3
24
30
30