background image

REV 42451-20140110  

8

42451

 

ENGLISH

Grounding

Your generator must be properly connected to an 
appropriate ground to help prevent electric shock.

A ground terminal connected to the frame of the generator 
has been provided on the power panel. For remote 
grounding, connect of a length of heavy gauge (12 AWG 
minimum) copper wire between the generator ground 
terminal and a copper rod driven into the ground. We 
strongly recommend that you consult with a qualified 
electrician to ensure compliance with local electrical codes.

ASSEMBLY

Failure to properly ground the generator can result 
in electric shock.

WARNING

Add Fuel

1.  Use clean, fresh, regular unleaded fuel with a 

minimum octane rating of 85 and an ethanol content 
of less than 10% by volume.

2.  DO NOT mix oil with fuel.
3.  Clean the area around the fuel cap. 
4.  Remove the fuel cap.
5.  Slowly add fuel to the tank. DO NOT OVERFILL. Fuel 

can expand after filling. A minimum of 0,64 cm (¼ in.) 
of space left in the tank is required for fuel expansion, 
more than 0,64 cm (¼ in.) is recommended. Fuel can 
be forced out of the tank as a result of expansion if it is 
overfilled, and can affect the stable running condition of 
the product. When filling the tank, it is recommended 
to leave enough space for the fuel to expand.

6.  Screw on the fuel cap and wipe away any spilled fuel.

Use regular unleaded gasoline with a minimum 

octane rating of 85.

Do not mix oil and gasoline.
Fill tank to approximately 0,64 cm (¼ in.) below 
the top of the tank to allow for fuel expansion.
DO NOT pump gas directly into the generator at the 
gas station. Use an approved container to transfer 
the fuel to the generator.
DO NOT fill fuel tank indoors.
DO NOT fill fuel tank when the engine is running or hot.
DO NOT overfill the fuel tank.
DO NOT light cigarettes or smoke when filling the 
fuel tank.

CAUTION

Pouring fuel too fast through the fuel screen may 

result in blow back of fuel at the operator while filling.

WARNING

Our engines work well with 10% or less ethanol 
blend fuels. When using blended fuels there are 
some issues worth noting: 

 

– Ethanol-gasoline blends can absorb more water 

than gasoline alone. 

 

– These blends can eventually separate, leaving 

water or a watery goo in the tank, fuel valve and 
carburetor. 

 

– With gravity-fed fuel supplies, this compromised 

fuel can be drawn into the carburetor and cause 
damage to the engine and/or potential hazards. 

 

– There are only a few suppliers of fuel stabilizer 

that are formulated to work with ethanol blend 
fuels.

 

– Any damages or hazards caused by using 

improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not 
covered by manufacture’s warranty. 

It is advisable to always shut off the fuel supply, 
run the engine to fuel starvation and drain the tank 
when the equipment is not in use for more than 30 
days.

NOTE

Add Fuel Cont’d.

Содержание 42451

Страница 1: ...Santa Fe Springs CA 90670 USA 1 877 338 0999 www championpowerequipment com 1500 Starting Watts 1200 Rated Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included i...

Страница 2: ...ghtly from the image on the cover AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40 C 104 F W...

Страница 3: ...Maintenance And Storage 11 Engine Maintenance 11 Oil 11 Spark Plugs 11 Air Filter 11 Spark Arrester 12 Cleaning 12 Adjustments 12 Maintenance Schedule 12 Generator Maintenance 12 Storage 13 Generator...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...inds of information The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment Follow all safety messages to avoid or reduce the risk of seriou...

Страница 6: ...metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can re...

Страница 7: ...nd let it cool for at least two minutes before removing the fuel cap Loosen the cap slowly to relieve pressure in the tank Only fill or drain fuel outdoors in a well ventilated area DO NOT pump gas di...

Страница 8: ...Used to start the engine 3 Fuel Valve Turn this valve to the On position to supply fuel to the engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Start...

Страница 9: ...Alternator Side Mount 1 Engine Switch Flip the switch to the On position and pull the recoil starter to start the generator Turn to the Off position to turn off the generator 2 Circuit Breaker Protect...

Страница 10: ...o additional lubrication for the life of the bearing NOTE DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil Damage to the gener...

Страница 11: ...fuel Use regular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately 0 64 cm in below the top of the tank to allow for fuel expansion DO NOT pum...

Страница 12: ...tment of a recreational vehicle Please consult your local authority In some areas generators must be registered with the local utility Generators used at construction sites may be subject to additiona...

Страница 13: ...he law In addition this action if done incorrectly could damage your generator and appliances and could cause serious injury or even death to you or a utility worker who may be working on nearby power...

Страница 14: ...et and extension 2 Allow the oil to drain completely 3 Replace the drain plug 4 Remove oil fill cap dipstick to add oil 5 Add 0 4 qt 0 4 L of oil and replace oil fill cap dipstick DO NOT OVERFILL 6 Di...

Страница 15: ...cooling slots and damage the generator windings CAUTION Maintenance Schedule Follow the service intervals indicated in the following maintenance schedule Service your generator more frequently when o...

Страница 16: ...ll with 10 or less ethanol blend fuels When using blended fuels there are some issues worth noting Ethanol gasoline blends can absorb more water than gasoline alone These blends can eventually separat...

Страница 17: ...Model YF152FD 2 010 Displacement 80cc Type 4 Stroke OHV Start Type Recoil Spark Plugs OEM spark plug NHSP E6RTC Replacement spark plug NGK BPR6HS or equivalent Make certain the spark plug gap is 0 7...

Страница 18: ...arts Diagram SPECIFICATIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38 30 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 38 57 58 59 60 3...

Страница 19: ...1 32 113 190002 01 End Housing 1KW 1 33 1 16674 0512 2 Flange Bolt M5 12 3 34 2 08 073 Flange Bolt M6 90 4 Part Number Description Qty 35 122 190003 00 48 Generator End Cover Yellow 1 36 5 1900 028 G...

Страница 20: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 61 62 63 64 65 66 67 68 74 75 76 77 7...

Страница 21: ...od 1 40 12 050005 02 Piston 1 41 2 09 005 Circlip 16 1 2 Part Number Description Qty 42 12 050003 01 Piston Pin 1 43 11 050303 00 Ring Oil 1 44 11 050302 00 Ring Second Piston 1 45 11 050301 00 Ring F...

Страница 22: ...19 REV 42451 20140110 ENGLISH 42451 Wiring Diagram SPECIFICATIONS...

Страница 23: ...power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not prope...

Страница 24: ...this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any electrical com...

Страница 25: ...ject to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be repaired or replaced by CPE OWNER WARRAN...

Страница 26: ...all be warranted for the remainder of the ECS Warranty Period c Any warranted emissions related part which is scheduled for replacement as required maintenance in the Owner s Manual shall be warranted...

Страница 27: ...talled along with your warranty registration card or other proof of original purchase date at your expense to any Champion Power Equipment dealer who is authorized by Champion Power Equipment Inc to s...

Отзывы: