OPERATION

Grounding

The generator system ground connects the frame to the 
ground terminals on the power panel.

 

– The generator (stator winding) is isolated from the 

frame and from the AC receptacle ground pin. 

 

– Electrical devices that require a grounded receptacle 

pin connection may not function properly.

Surge Protection

Electronic devices, including computers and many 
programmable appliances use components that are 
designed to operate within a narrow voltage range and 
may be affected by momentary voltage fluctuations. 
While there is no way to prevent voltage fluctuations, you 
can take steps to protect sensitive electronic equipment. 

1.  Install UL1449, CSA-listed, plug-in surge suppressors 

on the outlets feeding your sensitive equipment. 

 

Surge suppressors come in single- or multi-outlet 
styles. They’re designed to protect against virtually 
all short-duration voltage fluctuations.

Voltage fluctuation may impair the proper 
functioning of sensitive electronic equipment.

CAUTION

If the engine starts but does not run make certain 
that the generator is on a flat, level surface. The 
engine is equipped with a low oil sensor that will 
prevent the engine from running when the oil level 
falls below a critical threshold.

NOTE

Starting the Engine

1.  Make certain the generator is on a flat, level surface.
2.  Disconnect all electrical loads from the generator. 

Never start or stop the generator with electrical 
devices plugged in or turned on.

3.  Turn the Fuel Valve to the “ON” position.
4.  Flip the engine switch to the “ON” position.
5.  Move the choke lever to the “CHOKE” position.
6.  Pull the starter cord slowly until resistance is felt and 

then pull rapidly

7.  Do not over-choke. As as soon as engine starts, move 

the choke lever to the “RUN” position.

Keep choke lever in “Choke” position for only 1 
pull of the recoil starter. After first pull, move choke 
lever to the “Run” position for up to the next 3 
pulls of the recoil starter. Too much choke leads to 
sparkplug fouling/engine flooding due to the lack of 
incoming air. This will cause the engine not to start.

NOTE

Generator Location

NEVER operate the generator inside any building, 
including garages, basements, crawlspaces and sheds, 
enclosure or compartment, including the generator 
compartment of a recreational vehicle. Please consult 
your local authority. In some areas, generators must 
be registered with the local utility. Generators used at 
construction sites may be subject to additional rules and 
regulations. Generators should be on a flat, level surface 
at all times. (Even while not in operation) Generators 
must have at least 5 ft. (1.5 m) of clearance from all 
combustible material. In addition to clearance from 
all combustible material, generators must also have 
at least 3 ft. (91.4 cm) of clearance on all sides to 
allow for adequate cooling, maintenance and servicing. 
Generators should never be started or operated in the 
back of a SUV, camper, trailer, in the bed of a truck 
(regular, flat or otherwise), under staircases/stairwells, 
next to walls or buildings, or in any other location that 
will not allow for adequate cooling of the generator 
and/or the muffler. DO NOT contain generators during 
operation. Allow generators to properly cool before 
transport or storage.
Place the generator in a well-ventilated area. DO NOT 
place the generator near vents or intakes where exhaust 
fumes could be drawn into occupied or confined 
spaces. Carefully consider wind and air currents when 
positioning generator.

Failure to follow proper safety precautions may void 
manufacturer’s warranty.

Do not operate or store the generator in rain, snow, or 
wet weather.

Using a generator or electrical appliance in wet 
conditions, such as rain or snow, or near a pool or 
sprinkler system, or when your hands are wet, could 
result in electrocution.

WARNING

WARNING

During operation the muffler and exhaust fumes 
produced will become hot. If adequate cooling and 
breathing space are not supplied, or if the generator 
is blocked or contained, temperatures can become 
extremely heated and may lead to fire.

Содержание 42436

Страница 1: ...Santa Fe Springs CA 90670 USA 1 877 338 0999 www championpowerequipment com 1500 Starting Watts 1200 Rated Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included i...

Страница 2: ...roduct contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is desi...

Страница 3: ...nagement 11 Maintenance and Storage 12 Engine Maintenance 12 Oil 12 Spark Plugs 12 Air Filter 12 Spark Arrester 13 Cleaning 13 Adjustments 13 Maintenance Schedule 13 Generator Maintenance 14 Storage 1...

Страница 4: ...information available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most fro...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can re...

Страница 7: ...or off and let it cool for at least two minutes before removing the fuel cap Loosen the cap slowly to relieve pressure in the tank Only fill or drain fuel outdoors in a well ventilated area DO NOT pum...

Страница 8: ...ator CONTROLS AND FEATURES 1 Fuel Tank 1 5 gal 5 5 L capacity fuel tank 2 Choke Used to start the engine 3 Fuel Valve Turn this valve to the ON position to supply fuel to the engine 4 Air Cleaner Prot...

Страница 9: ...isplay alternator output voltage 3 Circuit Breaker Protects the generator against electrical overloads Push to reset breaker 4 120 Volt AC 20 Amp Receptacle NEMA 5 20R May be used to supply electrical...

Страница 10: ...Parts Included Your 42436 Gasoline Powered Generator ships with the following parts Other Vibration Mount Engine Side 2 Vibration Mount Alternator Side 2 Nut M8 4 Flange Bolt M8x20 2 Oil Funnel 1 Spa...

Страница 11: ...ngine Oil DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil Damage to the generator as a result of failure to follow these inst...

Страница 12: ...manufacture s warranty It is advisable to always shut off the fuel supply run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days NOTE Add Fuel 1 U...

Страница 13: ...pulls of the recoil starter Too much choke leads to sparkplug fouling engine flooding due to the lack of incoming air This will cause the engine not to start NOTE Generator Location NEVER operate the...

Страница 14: ...2 Total the running watts of these items This is the amount of power you need to keep your items running 3 Identify the highest starting wattage of all devices identified in step 1 Add this number to...

Страница 15: ...spark plug gap is 0 7 0 8 mm or 0 028 0 031 in 5 Refer to the spark plug recommendation chart when replacing the plug 6 Carefully thread the plug into the engine 7 Use the spark plug tool to firmly in...

Страница 16: ...can contaminate the fuel system MAINTENANCE AND STORAGE To be performed by knowledgeable experienced owners or Champion Power Equipment certified dealers Every 8 hours or daily Check oil level Clean...

Страница 17: ...s are disconnected from the generator 3 Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor 4 Turn the fuel valve to the Off position 5 Let the genera...

Страница 18: ...22 mm 0 007 0 009 in Note Tech bulletin regarding the valve adjustment procedure is on www championpowerequipment com Spark Plugs OEM spark plug NHSP E6RTC Replacement spark plug NGK BPR6HS or equiva...

Страница 19: ...REV 42436 20140115 16 42436 ENGLISH SPECIFICATIONS Wiring Diagram...

Страница 20: ...SPECIFICATIONS Parts Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38 30 39 40 41 42 43 44 45 46 47 32 33 33 48 49 50 51 52 53 54 55 56 38 57...

Страница 21: ...31 12 100100 01 Bracket Muffler 1 32 113 190002 01 End Housing 1KW 1 33 1 16674 0512 2 Flange Bolt M5 12 3 Part Number Description Qty 34 2 08 073 Flange Bolt M6 90 4 35 122 190003 00 48 Generator En...

Страница 22: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 61 62 63 64 65 66 67 68 74 75 76 77 7...

Страница 23: ...Rod 1 40 12 050005 02 Piston 1 41 2 09 005 Circlip 16 1 2 42 12 050003 01 Piston Pin 1 43 11 050303 00 Ring Oil 1 Part Number Description Qty 44 11 050302 00 Ring Second Piston 1 45 11 050301 00 Ring...

Страница 24: ...ank Low oil level Fill crankcase to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Powe...

Страница 25: ...labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any elec...

Страница 26: ...and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EMISSION CONTROL S...

Страница 27: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 28: ...rburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of original pur...

Отзывы: