background image

17

  

REV 41533-20110701

ENGLISH

 

41533

MAINTENANCE ANd STORAGE

Generator Maintenance

Make certain that the generator is kept clean and stored 
properly . Only operate the unit on a flat, level surface in 
a clean, dry operating environment . DO NOT expose the 
unit to extreme conditions, excessive dust, dirt, moisture 
or corrosive vapors .

Storage

The generator should be started at least once every 14 
days and allowed to run for at least 20 minutes . For 
longer term storage, please follow these guidelines .

Generator Storage

1 .  Allow the engine to cool completely before storage .
2 .  Clean the generator according to the instructions in 

the Maintenance section .

3 .  Turn the Fuel Valve to the “OFF” position .
4 .  Be sure all appliances are disconnected from the 

generator . Start the engine and let it run until the 
fuel in the line and the carburator is consumed and 
the engine dies .

5 .  Press the Battery Switch to “OFF” .
6 .  Add a fuel stabilizer into the fuel tank .
7 .  Change the oil .
8 .  Remove the spark plug and pour about ½ ounce 

of oil into the cylinder . Crank the engine slowly to 
distribute the oil and lubricate the cylinder .

9 .  Reattach the spark plug .
10 . Store the unit in a clean, dry place out of direct 

sunlight .

Use a damp cloth to clean exterior surfaces of the generator .
Use a soft bristle brush to remove dirt and oil .
Use an air compressor (25 PSI) to clear dirt and debris 
from the generator . 
Inspect all air vents and cooling slots to ensure that they 
are clean and unobstructed .

DO NOT use a garden hose to clean the generator .

Water can enter the generator through the cooling 
slots and damage the generator windings .

CAUTION

disconnect the Battery

1 .  Remove the protective cover from the black/negative 

battery lead .

2 .  Disconnect the black/negative lead from the black/

negative terminal on the battery and store the cap 
screw (M5x12) and lock washer (M5) .

3 .  Repeat steps 1-2 for the red/positive battery lead .
4 .  Store the battery in a cool, dry place .

Charge the Battery

For generators equipped with batteries for electric 
starting, proper battery maintenance and storage 
should be followed . An automatic battery charger with 
automatic trickle charging capability should be used to 
charge the battery . Maximum charging rate should not 
exceed 1 .5 amps . Follow the instructions included with 
the battery charger . The battery should be fully charged 
at least once per month .

Generator exhaust contains odorless and colorless 
carbon monoxide gas .

To avoid accidental or unintended ignition of your 
remote start generator during periods of storage, 
the following precautions should be followed:

 

– When 

storing the generator for short periods of

time

 make sure that the Ignition Switch, the Fuel

Valve and the Battery Switch are set in the 

OFF

 

position . 

 

– When 

storing the generator for extended periods 

of time

 make sure that the Ignition Switch, the 

Fuel Valve and the Battery Switch are set in the 
the the 

OFF

 position and the battery leads have 

been 

disconnected

 from the battery . 

dANGER

Содержание 41533

Страница 1: ...CA 90670 USA 1 877 338 0999 www championpowerequipment com 9200 Starting Watts 7200 Running Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual...

Страница 2: ...he store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Car...

Страница 3: ...pacity 13 Power Management 13 Wattage Reference Chart 14 Operation at High Altitude 14 Maintenance and Storage 15 Engine Maintenance 15 Oil 15 Spark Plugs 15 Air Filter 15 Spark Arrester 16 Cleaning 1...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...nd remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught Generator produces powerful voltage DO NOT touch bare...

Страница 7: ...ull hand and arm towards the engine faster than you can let go Unintentional startup can result in entanglement traumatic amputation or laceration Broken bones fractures bruises or sprains could resul...

Страница 8: ...rt the engine No manual adjustment required 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Start...

Страница 9: ...20 Volt AC 30 Amp Twist Lock Receptacle NEMA L5 30R May be used to supply electrical power for the operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 6 120 240 Volt AC 30 Amp Twist Lo...

Страница 10: ...ving the Ignition Switch to the OFF position disables the Remote functions but the RCM still consumes approximately 2 mA from the battery To prevent battery drain press the Battery Switch to the OFF p...

Страница 11: ...h the following parts Wheel Kit 10 Wheel 2 Flange Bolt M10x120 for Wheel 2 Bushing 2 Flat Washer 10 2 Nut M10 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Nut M8 2 Other Oil...

Страница 12: ...he following tools to install the wheels 17 mm wrench OR adjustable wrench not included Socket wrench with a 16 mm socket not included Pliers not included 1 Before adding fuel and oil tip the generato...

Страница 13: ...shutoff and will stop when the oil level in the crankcase falls below the threshold level CAUTION Add Engine Oil DO NOT attempt to crank or start the engine before it has been properly filled with the...

Страница 14: ...or fuel expansion DO NOT fill fuel tank indoors DO NOT fill fuel tank when the engine is running or hot DO NOT overfill the fuel tank DO NOT light cigarettes or smoke when filling the fuel tank CAUTIO...

Страница 15: ...tage fluctuations Voltage fluctuation may impair the proper functioning of sensitive electronic equipment CAUTION Operation Starting the Engine without Remote 1 Make certain the generator is on a flat...

Страница 16: ...any power lines You are responsible for ensuring that your generator s electricity does not feed back into the electric utility power lines If the generator will be connected to a building electrical...

Страница 17: ...h Altitude The density of air at high altitude is lower than at sea level Engine power is reduced as the air mass and air fuel ratio decrease Engine power and generator output will be reduced approxim...

Страница 18: ...plug 8 Attach the spark plug wire to the plug For service or parts assistance contact our help line at 1 877 338 0999 NOTE Maintenance replacement or repair of emission control devices and systems ma...

Страница 19: ...ster to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if it is damaged 6 Position...

Страница 20: ...pect all air vents and cooling slots to ensure that they are clean and unobstructed DO NOT use a garden hose to clean the generator Water can enter the generator through the cooling slots and damage t...

Страница 21: ...terference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on th...

Страница 22: ...19 REV 41533 20110701 ENGLISH 41533 Specifications Parts Diagram...

Страница 23: ...89 FB6 8 Flange Bolt M6 8 2 59 ST05FD 1151600 Cover 1 60 ST05FD 1152008 Plug A 1 61 ST05FD 1152009 Plug B 1 62 ST190FDE 2 G1 Engine 1 Part Number Description Qty 63 ST182FD 1742203 UC Handle Cover 1 6...

Страница 24: ...21 REV 41533 20110701 ENGLISH 41533 Specifications Engine Parts Diagram...

Страница 25: ...2 Intake Stud 2 58 F6RTC Spark plug 1 59 ST188F 1122000 G Ignition Coil 1 60 GB5789 FB6 29 Flange Bolt M6 29 4 Part Number Description Qty 61 ST188FD 1130003 CPE Carburetor Insulator Packing 1 62 ST18...

Страница 26: ...23 REV 41533 20110701 ENGLISH 41533 Wiring Diagram Specifications...

Страница 27: ...e to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient venti...

Страница 28: ...r labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any ele...

Страница 29: ...uding diagnosis parts and labor MANUFACTURER S EMISSION CONTROL SYSTEM WARRANTY COVERAGE This emission control system is warranted for two years subject to provisions set forth below If during the war...

Страница 30: ...s scheduled for replacement as required maintenance in the Owner s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior...

Страница 31: ...ting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof...

Отзывы: