The owner/operator is responsible for all periodic 
maintenance.

Complete all scheduled maintenance in a timely manner. 
Correct any issue before operating the generator.

Never operate a damaged or defective generator.

Tampering with the factory set governor will void 
your warranty.

Engine Maintenance

To prevent accidental starting, remove and ground spark 
plug wire before performing any service.

Oil

Change oil when the engine is warm. Refer to the oil 
specification to select the proper grade of oil for your 
operating environment.
1.  Remove the oil drain plug with a 12 mm socket and 

extension.

2.  Allow the oil to drain completely.
3.  Replace the drain plug.
4.  Remove oil fill cap/dipstick to add oil.
5.  Add 0.63 qt. (0.6 L) of oil and replace oil fill 

cap/dipstick. DO NOT OVERFILL.

6.  Dispose of used oil at an approved waste 

management facility.

Air Filter

1.  Remove the snap-on cover holding the air filter to 

the assembly.

2.  Remove the foam element. 
3.  Wash in liquid detergent and water. Squeeze 

thoroughly dry in a clean cloth.

4.  Saturate in clean engine oil. 
5.  Squeeze in a clean, absorbent cloth to remove all 

excess oil.

6.  Place the filter in the assembly.
7.  Reattach the air filter cover and snap in place.

Spark Plugs

1.  Remove the spark plug cable from the spark plug.
2.  Use the spark plug tool that shipped with your 

generator to remove the plug.

3.  Inspect the electrode on the plug. It must be clean and 

not worn to produce the spark required for ignition.

4.  Make certain the spark plug gap is 0.6 - 0.8 mm or 

(0.024 - 0.031 in.).

5.  Refer to the spark plug recommendation chart when 

replacing the plug.

6.  Carefully thread the plug into the engine.
7.  Use the spark plug tool to firmly install the plug.
8.  Attach the spark plug wire to the plug.

For service or parts assistance, contact our help 
line at 

1-877-338-0999

NOTE

Maintenance, replacement, or repair of emission 
control devices and systems may be performed 
by any non-road engine repair establishment or 
individual.

NOTE

WARNING

WARNING

Improper maintenance will void your warranty.

WARNING

Oil Cont’d.

Once oil has been added, a visual check should show 
oil about 1-2 threads from running out of the fill hole.
If using the dipstick to check oil level, DO NOT screw 
in the dipstick while checking.

NOTE

MAINTENANCE AND STORAGE

0.6 - 0.8 mm

(0.024 - 0.031 in.)

Содержание 40730

Страница 1: ...Fe Springs CA 90670 USA 1 877 338 0999 www championpowerequipment com SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 40730 20130609 40730 MODEL NUM...

Страница 2: ...roduct contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is desi...

Страница 3: ...l 13 Spark Plugs 13 Air Filter 13 Spark Arrester 14 Cleaning 14 Adjustments 14 Maintenance Schedule 14 Generator Maintenance 15 Storage 15 Generator Storage 15 Specifications 16 Engine Specifications...

Страница 4: ...information available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most fro...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can r...

Страница 7: ...ay create sparks that can start fires around dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention require...

Страница 8: ...ank 3 3 gallon 12 5 L capacity fuel tank 2 Choke Used to start the engine 3 Fuel Valve Turn this valve to the ON position to supply fuel to the engine 4 Air Cleaner Protects the engine by filtering du...

Страница 9: ...ist Lock Receptacle NEMA L5 30R May be used to supply electrical power for the operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 5 120 Volt AC 30 Amp Receptacle NEMA TT 30R May be us...

Страница 10: ...s with the following parts Wheel Kit 8 in Wheel 2 Pin Roll 16x90 for Wheel 2 Garter Spring B 2 Handle 1 Support Leg w Vibration Mounts 1 Flange Bolt M8x45 for Handle 2 Flange Bolt M8x16 for Support Le...

Страница 11: ...stall the wheel kit and support leg Install the Wheel Kit 1 Before adding fuel and oil tip the generator on it s side 2 Slide the wheel pin roll 34 through the wheel 35 from the outside 3 Slide the pi...

Страница 12: ...in period Refer to the Maintenance section for recommended service intervals NOTE The generator rotor has a sealed pre lubricated ball bearing that requires no additional lubrication for the life of t...

Страница 13: ...compromised fuel can be drawn into the carburetor and cause damage to the engine and or potential hazards There are only a few suppliers of fuel stabilizer that are formulated to work with ethanol bl...

Страница 14: ...eration the muffler and exhaust fumes produced will become hot If adequate cooling and breathing space are not supplied or if the generator is blocked or contained temperatures can become extremely he...

Страница 15: ...electrical loads Never start or stop the generator with electrical devices plugged in or turned on 2 Let the generator run at no load for several minutes to stabilize internal temperatures of the engi...

Страница 16: ...rate in clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove the spa...

Страница 17: ...ir compressor 25 PSI to clear dirt and debris from the engine Cleaning DO NOT spray engine with water CAUTION Water can contaminate the fuel system Adjustments The air fuel mixture is not adjustable T...

Страница 18: ...ances are disconnected from the generator 3 Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor 4 Turn the fuel valve to the Off position 5 Let the ge...

Страница 19: ...rding the valve adjustment procedure is on www championpowerequipment com Spark Plugs OEM spark plug NHSP F6RTC Replacement spark plug NGK BPR6ES or equivalent Make certain the spark plug gap is 0 6 0...

Страница 20: ...17 REV 40730 20130609 ENGLISH 40730 SPECIFICATIONS Parts Diagram...

Страница 21: ...G73 0101 Connection Tube Assembly2 1 41 6114D C14 0101 Carbon Canister 1 42 61181 QD03 0000 Bushing 2 Part Number Description Qty 43 61182 QD03 0000 Vibration Pad 2 44 B057890006001870B Flange Bolt M6...

Страница 22: ...19 REV 40730 20130609 ENGLISH 40730 SPECIFICATIONS Engine Parts Diagram...

Страница 23: ...r Arm 1 52 90101 10052000190 Washer 5 2 1 9 1 53 T1105006001100400 Oil Seal 6 11 4 1 54 24606 KB01 0000 Pin Shaft 1 55 92102 00TM6205P63 Bearing Tm6205 P63 2 Part Number Description Qty 56 91302 92500...

Страница 24: ...21 REV 40730 20130609 ENGLISH 40730 SPECIFICATIONS Wiring Diagram...

Страница 25: ...e to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient venti...

Страница 26: ...labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any elec...

Страница 27: ...ts and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EMISSION CONTRO...

Страница 28: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 29: ...rburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of original pur...

Отзывы: