200914 - 4250W DUAL FUEL OPEN FRAME INVERTER
OPERATION
20
OPERATION
Generator Location
WARNING
NEVER operate the generator inside any building, garage,
basement, crawlspace, shed, enclosure or compartment,
including a generator compartment of a recreational vehicle.
NEVER operate or start the generator in the back of an
SUV, camper, trailer, truck bed (regular sides, flat or other
configuration), under staircases, stairwells, next to walls
or buildings or in any other location that will not allow for
adequate cooling of the generator or for the proper exit of the
exhaust flow from the muffler system.
DO NOT operate or store the generator in wet weather
conditions such as rain or snow. Using a generator in wet
conditions could result in serious injury or death due to
electrocution.
In some state’s generators may be required to be registered
with the local utility company when used at construction sites
and may be subject to additional rules and regulations, consult
your local municipal authority.
Generators should always be operated on a flat, level surface
at all times (even when not in operation).
Generators must have a minimum of 5 feet (1.5 m) of
clearance from all combustible material.
Generators must also have a minimum of 3 feet (91.4 cm)
of air flow clearance on all sides to allow for adequate
performance cooling, maintenance and servicing.
Always place the generator in a well-ventilated area. NEVER
place the generator near air intake vents or where exhaust
fumes could be drawn into occupied or confined spaces.
Always carefully consider wind and air currents when
positioning generator.
Always allow generators to properly cool before transport or
for storage purposes.
Failure to follow proper safety precautions may result in
personal injury, damage to the generator and void the
manufacturer’s warranty.
WARNING
During operation the muffler and exhaust fumes will become
hot. If adequate cooling and breathing space are not supplied,
or if the generator is blocked or enclosed, temperatures can
become extremely heated and may lead to fire.
WARNING
Do not expose to rain or use in damp locations.
Keep all objects a minimum of 5 feet (1.5m) away from the
generator at all times. Heat from the muffler surface and
exhaust gas stream can ignite combustible materials.
WARNING
If you must operate in rain or damp locations, DO NOT operate
without proper protection of the electrical components.
Use of a safety canopy that is fire retardant and will provide proper
air ventilation for the engine exhaust gas stream may be used.
Visit championpowerequipment.com or call to find your Storm
Shield cover.
Surge Protection
Electronic devices, including computers and many programmable
appliances use components that are designed to operate within a
narrow voltage range and may be affected by momentary voltage
fluctuations. While there is no way to prevent voltage fluctuations,
you can take steps to protect sensitive electronic equipment.
–
Install UL1449, CSA-listed, plug-in surge suppressors on the
outlets feeding your sensitive equipment.
Surge suppressors come in single- or multi-outlet styles.
They’re designed to protect against virtually all short-duration
voltage fluctuations.
Starting the Engine: Gasoline
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never start
or stop the generator with electrical devices plugged in or
turned on.
3. Turn the fuel selector dial to the gasoline “RUN” position.