1 Steam Supply: Consumption: 175 lbs./hr. @ 15 psi minimum

2 Gas Supply: Consumption:

110,000 BTU/hr.

Certifications

                        

UL and UL Sanitation Listed (all). CUL Listed (electric and steam only).

Steam Exhaust Vent

Steam exhaust vent 12-7/8" diameter, consisting of 14 gauge rolled rolled for PVC
pipe connection bolted to the top of the machine. Machine pre-wired with control
timer for the addition of a fan.

Optional Exhaust Fan

12" diameter exhaust fan mounted on washer to extract steam after rinse cycle.
Constructed for moisture laden air or other air steam contaminants. 500 CFM @
.5" static pressure. 1/4 Hp, 1725 RPM.

Optional Hood & Fan

Stainless steel hood and fan assembly, mounted over door to evacuate steam that
escapes when door is opened.

Racks

Customized to hold your specific items. Constructed of stainless steel rod and formed
angle, mig welded. Supplied with stainless steel casters and nylon wheels.

Connections

Water Inlet: 120 degrees F, 1" NPT
Water Drain: 2" NPT
Overflow: 2" NPT
Electrical: Two point connection except 575 volt, which is single point.
Steam Heating Option: 1/2" NPT
Natural or Propane Gas Heating Option: 1/2" NPT

Services

120 Volt — 1 phase, 5 running amps, 15 amp service, plus one of the following
(except for 575 volt, which is single point connection):

18

36

38

18

36

38

63

480 Volt
3 phase

126

240 Volt
3 phase

138

208 Volt
3 phase

Elec. Spec.

Infrared Gas Wash2

Infrared Gas Booster

Steam Wash1

Steam Booster

Electric Wash

Electric Booster

Running Amps

Содержание 1527-N

Страница 1: ...ctric infrared gas or steam heating Moisture resistant control gauges Designed for pit or ramp installations Digital Control Information Center One year parts and labor warranty Project Item No Quantity 1527 1536 Champion Industries Inc P O Box 4149 Winston Salem NC 27115 Tel 336 661 1556 Fax 336 661 1979 2674 N Service Road Jordan Station Ontario Canada L0R 1S0 Tel 905 562 4195 Fax 905 562 4618 w...

Страница 2: ...480 volt 3 phase 60 cycle with output of 250 gallons per minute at 35 to 45 P S I Digital Control Information Center 110 volt control circuit with push pad operation of Power On Stop and Short Medium or Long Wash Cycles A digital display indicates Time Remaining for each cycle LED s indicate wash rinse and unload functions A buzzer is also included to provide an audible indication of time to unloa...

Страница 3: ...type Double filter system for increased effectiveness and easy cleaning without emptying wash tank Fill Valve Size 1 2 brass material solenoid type for automatic option Drain Valve Size 2 brass material gate type for manual or electrically operated ball valve for automatic option Wash Pump 15 hp 208 240 or 480 volt 3 phase 60 cycle Close coupled 250 gallons per minute at 35 to 45 psi mounted on 12...

Страница 4: ...r rinse cycle Constructed for moisture laden air or other air steam contaminants 500 CFM 5 static pressure 1 4 Hp 1725 RPM Optional Hood Fan Stainless steel hood and fan assembly mounted over door to evacuate steam that escapes when door is opened Racks Customized to hold your specific items Constructed of stainless steel rod and formed angle mig welded Supplied with stainless steel casters and ny...

Отзывы: