14
Installation
VENTILATION - VENT HOOD FAN CONTROL
Standard model installations using an approved vent hood may require a vent
fan signal. This signal is supplied by the dishwasher control circuit. A qualified
installer must connect a signal circuit to the fuse holder and a common
neutral terminal provided. See Fig. 15.
CAUTION:
To prevent damage to the dishwasher do
not connect the vent fan motor to Line Power 120VAC,
1.0 Amp fused connection terminals. The fused 120VAC
Line Power only supplies an external vent fan contactor
(supplied by others), and is limited to 1.0 AMP maximum
load. The 120VAC is powered whenever main power is on.
Fig. 15 - Connection is
located inside the top
control cabinet.
1.0A
PANT LEG DUCT SETTING
NOTE:
Loosen the wing-nut holding the damper handle
and turn it to open or close the damper to adjust
the steam exiting the machine.
Fig. 16 - Duct.
Wing-nut
Damper
Handle
• LOAD END = 200CFM @ 1/4" SP, 71L/SEC.
• UNLOAD END = 400CFM @ 1/4" SP, 189L/SEC.
• ADEQUATE AIR CHANGES SHOULD BE CONSIDERED
BY THE HVAC CONTRACTOR.
• 4" X 16" VENT STACKS WITH ADJUSTABLE DAMPERS ARE
SUPPLIED BY FACTORY.