100302 - 4000W DIGITAL HYBRID PORTABLE GENERATOR
STORAGE
21
-1
EVERY 250 HOURS
Clean combustion chamber*
Check/adjust valve clearance*
EVERY 3 YEARS
Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certified service
centers.
STORAGE
DANGER
Gasoline vapors are highly flammable and extremely explosive.
Fire or explosion can cause severe burns or death. Only
fill or drain fuel outdoors in a well-ventilated area. DO NOT
pump gasoline directly into the generator. Use an approved
container to transfer the fuel to the generator. Never use a
gasoline container, gasoline tank, or any other fuel item that
is damaged or appears damaged. DO NOT overfill the gasoline
tank. Always keep fuel away from sparks, open flames, pilot
lights, heat and other sources of ignition.
DO NOT light or smoke cigarettes.
Short Term Storage (up to 30 days)
Gasoline may gum up and clog the carburetor if the generator is
not run or carburetor drained within 4 weeks.
1. Be sure all appliances are disconnected from the generator.
2. Start the generator as instructed in
Starting the Engine
section.
3. Turn the fuel valve to the “OFF” position.
4. Let the engine run until fuel starvation has stopped the
engine. This usually takes a few minutes.
5. Move the engine switch to the “OFF” position.
Mid Term Storage (30 days – 1 year)
Gasoline in the tank has a maximum shelf life of up to 1 year with
the addition of a properly formulated fuel stabilizer and stored in a
cool, dry place.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the gasoline tank.
3. Turn the fuel valve to the “ON” position.
4. Start and run the generator for 10 minutes so the treated
gasoline cycles through the fuel system.
5.
Option 1: Drain Gasoline from Carburetor
5a. Turn engine switch to the “OFF” position and allow
generator to cool completely before continuing.
5b. Turn the fuel valve to the “OFF”.
5c. Use the drain bolt on the carburetor to empty any
excess gasoline from the carburetor into an appropriate
container. Use a funnel (and appropriate hose if
necessary) under the carburetor drain bolt to avoid
spillage.
5d. When gasoline stops flowing from the carburetor, replace
and tighten the carburetor drain bolt and be sure to
properly dispose of the drained gasoline according to
local regulations or guidelines.
6.
Option 2: Run Dry
6a. With the generator running, turn the fuel valve to the
“OFF” position and allow the generator to run until the
engine stops from complete fuel starvation. This may
take a few minutes.
6b. Turn engine switch to the “OFF” position and allow
generator to cool completely before continuing.
7. Remove the spark plug cap and spark plug and pour about a
tablespoon of oil into the cylinder.
8. Pull the recoil cord slowly to crank the engine to distribute the
oil and lubricate the cylinder.
9. Install the spark plug and spark plug cap.
10. Clean the generator according to Cleaning the Generator.
11. Store the generator in a cool, dry place out of direct sunlight.
Long Term Storage (over 1 year)
For storage over 1 year, the gasoline tank and carburetor must be
completely drained of gasoline.
1. The generator is to be OFF and all appliances disconnected.
2. Turn the fuel valve to the “ON” position.
3. Use the drain bolt on the carburetor to empty any excess
gasoline from the gasoline tank and carburetor into an
appropriate container. Use a funnel (and appropriate hose if
necessary) under the carburetor drain bolt to avoid spillage.
4. When gasoline stops flowing from the carburetor, replace
and tighten the carburetor drain bolt and be sure to properly
dispose of the drained gasoline according to local regulations
or guidelines.
5. Turn the fuel valve to the “OFF” position.
6. Follow steps 7-11 according to
Mid
Term Storage.