background image

11

ENGLISH

 

100111

ASSEMBLy

Add fuel Cont’d.

Grounding

Your generator must be properly connected to an 
appropriate ground to help prevent electric shock.

A ground terminal connected to the frame of the generator 
has been provided on the power panel. For remote 
grounding, connect of a length of heavy gauge  
(12 AWG minimum) copper wire between the generator 
ground terminal and a copper rod driven into the ground. 
We strongly recommend that you consult with a qualified 
electrician to ensure compliance with local electrical codes.

Failure to properly ground the generator can result 
in electric shock.

WARNING

Champion engines work well with 10% or less 
ethanol blend fuels. When using blended fuels there 
are some issues worth noting: 

 

– Ethanol-gasoline blends can absorb more water 

than gasoline alone. 

 

– These blends can eventually separate, leaving 

water or a watery goo in the tank, fuel valve and 
carburetor. 

 

– With gravity-fed fuel supplies, this compromised 

fuel can be drawn into the carburetor and cause 
damage to the engine and/or potential hazards. 

 

– There are only a few suppliers of fuel stabilizer 

that are formulated to work with ethanol blend 
fuels.

 

– Any damages or hazards caused by using 

improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not 
covered by manufacture’s warranty. 

It is advisable to always shut off the fuel supply, 
run the engine to fuel starvation and drain the tank 
when the equipment is not in use for more than 30 
days.

NOTE

Add fuel

1.  Use clean, fresh, regular unleaded fuel with a 

minimum octane rating of 85 and an ethanol content 
of less than 10% by volume.

2.  DO NOT mix oil with fuel.
3.  Clean the area around the fuel cap. 
4.  Remove the fuel cap.
5.  Slowly add fuel to the tank. DO NOT OVERFILL.  

Fuel can expand after filling. A minimum of ¼ in. 
(6.4 mm) of space left in the tank is required 
for fuel expansion, more than ¼ in. (6.4 mm) is 
recommended. Fuel can be forced out of the tank as 
a result of expansion if it is overfilled, and can affect 
the stable running condition of the product. When 
filling the tank, it is recommended to leave enough 
space for the fuel to expand.

6.  Screw on the fuel cap and wipe away any spilled fuel.

Use regular unleaded gasoline with a minimum 
octane rating of 85.

Do not mix oil and gasoline.
Fill tank to approximately ¼ in. (6.4 mm) below the 
top of the tank to allow for fuel expansion.
DO NOT pump gas directly into the generator at the 
gas station. Use an approved container to transfer 
the fuel to the generator.
DO NOT fill fuel tank indoors.
DO NOT fill fuel tank when the engine is running or hot.
DO NOT overfill the fuel tank.
DO NOT light cigarettes or smoke when filling the 
fuel tank.

CAUTION

Pouring fuel too fast through the fuel screen may 
result in blow back of fuel at the operator while filling.

WARNING

Содержание 100111

Страница 1: ...Year Limited Warrant y Garantie li m i t e d e d e u x a n s Garantie li m i t e d e d e u x a n s G a r a n t a l i m i t a d a d e dos a os G a r a n t a l i m i t a d a d e dos a os T h ree Year Li...

Страница 2: ...rts Ordering Mon Fri 8 30 AM 5 00 PM PST PDT Toll Free 1 877 338 0999 AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is designed and rated for continuous operation at amb...

Страница 3: ...12 Connecting Electrical Loads 13 Stopping the Engine 13 Do Not Overload Generator 14 Capacity 14 Power Management 14 Operation at High Altitude 14 GFCI 15 Maintenance and Storage 16 Engine Maintenan...

Страница 4: ...ensure the accuracy and completeness of the information in this manual and we reserve the right to change alter and or improve the product and this document at any time without prior notice Since CPE...

Страница 5: ...s situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result...

Страница 6: ...ontaining conductive material such as metal decking Use approved transfer equipment to isolate generator from your electric utility and notify your utility company before connecting your generator to...

Страница 7: ...he holes in the lift bar DO NOT attempt to refuel or perform any maintenance while the generator is in the air at any height WARNING Fuel and fuel vapors are highly flammable and extremely explosive F...

Страница 8: ...AVERTISSEMENT MISE EN GARDE GN SF T 005D 1 WHEN STORING GASOLINE PROPANE LPG OR EQUIPMENT WITH FUEL IN IT Store away from furnaces stoves water heaters or other appliances that have a pilot light or...

Страница 9: ...his manual for future reference 1 Spark Plug Arrester and Muffler 2 Oil Filter 3 Air Filter Cover 4 Engine Access Cover 5 Power Panel See Power Panel section 6 Battery Used to start the engine 7 Fuel...

Страница 10: ...r Meter Displays the generator s output in reference to its rated wattage The greater the output the more LED s illuminate The LED bars will light up from green to orange If the orange LEDs light up t...

Страница 11: ...soline powered enerator ships with the following parts Wheel Kit 12 in Wheel 2 Pin Roll 16 x 12 x 116 for Wheel 2 R Shape Pin 2 Washer 12 2 Other Oil Funnel 1 Engine Oil 1 Flange bolt M5x12 for batter...

Страница 12: ...le check for any items that may be in the generator frame 2 With the generator still on the pallet install the wheel 3 Slide the wheel pin roll through the wheel from the outside 4 Slide the wheel pin...

Страница 13: ...tions will void your warranty CAUTION Assembly Check oil often during the break in period Refer to the Maintenance section for recommended service intervals NOTE The generator rotor has a sealed pre l...

Страница 14: ...acture s warranty It is advisable to always shut off the fuel supply run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days NOTE Add Fuel 1 Use cle...

Страница 15: ...ain or snow or near a pool or sprinkler system or when your hands are wet could result in electrocution WARNING WARNING During operation the muffler and exhaust fumes produced will become hot If adequ...

Страница 16: ...ower from utility power and must comply with all applicable laws and codes NOTE Operation Stopping the Engine 1 Turn off and unplug all electrical loads Never start or stop the generator with electric...

Страница 17: ...capacity when adding loads to the generator NOTE Operation Operation using the alternative main jet at elevations lower than the recommended minimum altitude can damage the engine For operation at lo...

Страница 18: ...is not stopped do not use this receptacle until is has been serviced or replaced 3 Press the Reset button located on the front of the receptacle to restore the flow of electricity If the indicator lig...

Страница 19: ...028 0 031 in 5 Refer to the spark plug recommendation chart when replacing the plug 6 Carefully thread the plug into the engine For service or parts assistance contact our help line at 1 877 338 0999...

Страница 20: ...ach with the two screws Failure to clean the spark arrester will result in degraded engine performance CAUTION Federal and local laws and administrative requirements indicate when and where spark arre...

Страница 21: ...ttery will receive charging voltage when the engine is running The battery will maintain a proper charge if the unit is used on a regular basis about once every two weeks If it is used less frequently...

Страница 22: ...F6RTC Replacement spark plug NGK BPR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 mm or 0 028 0 031 in Oil Use 10W 30 automotive oil Oil capacity is up to 1 4 qt 1 3 L DO NOT OVERFILL...

Страница 23: ...X A DUPLEX B 14 50R R GFCI W R R R 30A 50A 250V 50A DOUBLE POLE INTELLIGAUGE R G Y B B B B B B B B R R 250V 30A DOUBLE POLE L5 30R W 30A CIRCUIT BREAKER R R M Y ENGINE BLOCK BATTERY STARTER FUEL CUT S...

Страница 24: ...43 44 45 46 47 48 49 51 31 31 52 53 51 50 54 55 56 57 58 59 60 63 64 62 65 66 67 68 69 70 71 72 75 76 78 79 85 86 87 88 89 72 86 87 88 89 92 94 95 95 66 98 99 97 100 101 102 103 104 105 106 107 91 10...

Страница 25: ...72 200505 00 48 Protector cover 1 53 172 200501 00 48 Top cover 1 54 2 06 006 Clamp 7 x 1 2 Part Number Description Qty 55 172 070014 01 Pipe air cleaner 1220 mm 1 56 172 070014 00 Pipe reversal valve...

Страница 26: ...ble pole CSA 1 116 5 1210 920 20Amp circuit breaker push button 2 117 5 1210 930 30Amp circuit breaker push button 1 118 5 1440 005 Intelligauge four in one 1 119 717 130200 00 Pull choke assembly 1 1...

Страница 27: ...132 129 128 126 125 124 123 127 103 104 79 80 78 77 75 85 86 84 83 82 81 87 91 92 89 90 27 43 42 41 40 39 38 44 34 35 36 37 8 7 9 10 27 28 27 29 30 31 22 23 24 25 45 15 26 20 21 6 5 2 1 3 135 134 137...

Страница 28: ...in Jet Compl High Altitude Right 1 2 100189 Main Jet Compl Left 1 102021 Main Jet Compl High Altitude Left 1 Part Number Description Qty 43 61 130013 00 Connector Carburetor 1 44 1 5789 0665 Hex Flang...

Страница 29: ...ocket Head Cap 4 118 22 040012 00 Adjusting Lash 4 119 717 040200 02 Rocker Arm 4 120 101644 Gasket Rocker Cover 2 121 1 5789 0625 Hex Flange Bolt M6 x 25 8 122 101880 Clamp 100 mm 1 123 102263 Rocker...

Страница 30: ...l level Fill crankcase to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Manageme...

Страница 31: ...nt Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by CPE Other Exclusions This warranty excludes Cosmetic defects such a...

Страница 32: ...able condition exits CPE will repair your small off road engine SORE at no cost to you including diagnosis parts and labor MANUFACTURER S WARRANTY COVERAGE This exhaust and evaporative emission contro...

Страница 33: ...d for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CPE according...

Страница 34: ...Mounting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other p...

Отзывы: