RUNNING WATTAGE GUIDE

Starting loads may need as much as 3 times the Running Wattage for Electrical Motors. Check your appliance rating before using generator.

0

4000

500

1000

1500

2000

2500

3000

3500

Air Conditioner (12,000 BTU)
Air Conditioner (20,000 BTU)

Battery Charger 20 AMP
Battery Charger 12V DC

Belt Sander 3”

Bench Grinder 6”

Chain Saw

Circular Saw (6-12”)

Clothes Washer

Coffee Maker

Compressor (1HP)

Compressor (½ HP)

Compressor (3/4 HP)

Curling Iron

Demolition Hammer

Disc Sander (9”)

Edge Trimmer

Electric Blanket

Electrical Nail Gun

Electric Range - One Element

Electric Skillet

Freezer

Furnace Fan (1/3 HP)

Hair Dryer

Hand Drill (1”)

Hand Drill (½”)

Hand Drill (1/4”)
Hand Drill (3/8”)

Hedge Trimmer

Home Security

Impact Wrench

Jet Pump

Jigsaw

Lawn Mower

Light Bulb

Microwave

Milk Cooler

Oil Burner on Furnace

Oil Fired Space Heater (140,000 BTU)

Oil Fired Space Heater (30,000 BTU)
Oil Fired Space Heater (85,000 BTU)

Paint Sprayer, Airless (1/3 HP)

Paint Sprayer, Airless (handheld)

Portable Heater (5,000 BTU)

Radio

Refrigerator

Refrigerator/Freezer

Slow Cooker

Small Refrigerator

Submersible Pump (1 HP)

Submersible Pump (½ HP)

Submersible Pump (1-1/2 HP)

Sump Pump

Table Saw

Television

Toaster Oven

Water Heater

Weed Trimmer

1700

3300

500

110

1000

700

1200

800

1200

1000

2000

1400

1800

700

1300

1200

500

230

1200

1500

1250

500

1200
1200

1100

750

250

500

450

100

500

800

550

1200

100

700

1100

300

400

150

225

600

150

1550

50

600

1200

200

500

2000

1500

2800

600

1750

400

1500

4000

500

4

Содержание C42412-1

Страница 1: ...om grease fuel and other combustible materials Engine must not be run at excessive speeds Operating an engine at excessive speeds increases the hazard of personal injury Do not tamper with the parts which may increase or decrease the speed of the engine Do not operate this generator in the rain or unusually wet conditions This generator is designed for outdoor use only do not use this generator in...

Страница 2: ...ectrical frequency output 60 Hz Do not attempt to increase the speed of the engine for higher output Serious damage could occur to the generator engine or electrical appliance 3 AC Socket 120 V This outlet is protected by a 10 Amp push to reset circuit breaker This receptacle powers 120 Volt AC 60 Hz Single Phase loads requiring up to 10 AMPS or 1200 Watts of power WARNING Combined amperage of the...

Страница 3: ...N STARTING WATTAGE REQUIREMENTS 1 Some appli convert voltage and amperage to wattage a FORMULA VOLTS X AMPS WATTS b EXAMPLE Voltage and amperage for 1 3 HP furnace fan 120 Volts X 10 Amps 1200 Running Watts 2 To deter that was calculated by 3 times to assure adequate generator capacity If the nameplate information is not available use the values on the following page as a guide 3 Remem atts to sta...

Страница 4: ... Hand Drill Hand Drill 1 4 Hand Drill 3 8 Hedge Trimmer Home Security Impact Wrench Jet Pump Jigsaw Lawn Mower Light Bulb Microwave Milk Cooler Oil Burner on Furnace Oil Fired Space Heater 140 000 BTU Oil Fired Space Heater 30 000 BTU Oil Fired Space Heater 85 000 BTU Paint Sprayer Airless 1 3 HP Paint Sprayer Airless handheld Portable Heater 5 000 BTU Radio Refrigerator Refrigerator Freezer Slow ...

Страница 5: ...lt in engine failure Add gasoline 1 Use regular UNLEADED gasoline with the generator engine Do not use premium gasoline Do not mix oil with gasoline 2 Clean area around fuel fill cap remove cap 3 Slowly add unleaded regular gasoline to fuel tank Be careful not to overfill Allow about of tank space for fuel expansion 4 Install fuel cap and wipe up any spilled gasoline WARNING Never fill fuel tank i...

Страница 6: ...erate for 10 minutes before applying any electrical load 9 Plug in the desired 120 Volt AC single phase 60 Hz electrical load 1 Generator maintenance includes keeping the unit clean and dry 2 Operate and st Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material 3 Check the exterior surface 4 Check the oil level and air cleaner cleanliness at each ...

Страница 7: ...top of the threads when on a level surface MAXIMUM FILL MINIMUM FILL DRAIN PLUG DIP STICK CAUTION This engine is equipped with a low oil shut off and the engine will stop when engine oil falls below the minimum safe level Add oil immediately then restart engine CHECK ENGINE OIL LEVEL DAILY AND ADD AS NEEDED REGULAR SERVICE PERIOD Perform at every indicated month or operating hour interval whicheve...

Страница 8: ... and proof of purchase such as a copy of your sales receipt from one of CPE s retail customers Warranty registration and your receipt must be submitted within ten 10 days from the date of purchase Champion Power Equipment Repair Replacement Warranty CPE warrants to period of one 1 year from the original date of purchase 90 days for commercial industrial use This warranty only applies to the origin...

Страница 9: ... The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days If you have any questions regarding your warranty rights and responsibilities you should contact Champion Power Equipment Inc Customer Service 10006 Santa Fe Springs Road Santa Fe Springs CA 90670 Tel 562 236 9422 The emission warranty is a defects warranty Defects are judged on normal engine performance...

Страница 10: ... liable hereunder for failures of any warranted parts of a CPE engine caused by the use of such an unapproved add on or modified part Systems covered by this warranty Parts Description Fuel Metering System Air Induction System Ignition System Exhaust System Miscellaneous Parts Evaporative Emissions Fuel regulator Carburetor and internal parts Air cleaner Intake manifold Spark plug and parts Magnet...

Страница 11: ...PARTS DIAGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 7 7 50 51 11 ...

Страница 12: ...FD 3000006 ST154FD 3002000 ST154FD 3000007 ST154FD 11004000 ST154FD 3000008 GB16674 1996 M5x12 GB859 87 φ5 GB97 1 85 φ5 ST154FD 3000001 GB5789 86 M5x20 ST168FD 1152004 ST154FD 3000004 Name Bolt M6x22 Spring washer Flat washer Nut M6 Control panel Engine saw Bolt M6x12 DC socket DC circuit breaker AC circuit breaker AC socket Voltage meter Condenser Control panel cover Wire protect hose Vibration a...

Отзывы: