background image

Congratulations on your purchase of a Champion Power Equipment generator.  CPE designs and builds generators to 
strict specifications and with proper use and maintenance this generator should bring you years of satisfying service.

Read, study, and follow all instructions before operating this device.  Failure to heed these instructions may 
result in personal injury and/or property damage.

WARNING

Your generator can develop tremendous power forces and if used unsafely or improperly could result in property damage, serious 
injury, or death.  Throughout this manual you will find the following symbols for caution, warning, and danger.  Pay particular attention to 
the notes preceded by these symbols as they are written for your safety. Ultimately, safe operation of this device rests with you, the 
operator.

Indicates a hazard which, if not avoided, will result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided could result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or 
equipment damage.  This notation is also used to alert against unsafe practices.

CAUTION

SAFETY PRECAUTIONS

SAFETY AND OPERATION INSTRUCTIONS

Failure to follow these instructions and warnings may result in death, personal injury, or property damage.

WARNING

DANGER

Gasoline engines produce toxic carbon monoxide exhaust fumes.  Breathing exhaust fumes will cause serious injury 
or death.

WARNING

No modifications, alterations, or deviation to the generator are authorized by the manufacturer and should not be made.

Read, study, and understand the operator's manual prior to operation of this product.  Read, study and understand the 
engine manual prior to operation.  Follow all warnings and instructions.

Know your equipment.  Check the applications, limitations, and potential hazards with this unit and its placement or 
location.

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or 
other reproductive harm.

Gasoline is flammable. Check for spilled fuel or fuel leaks. Stop engine and allow to cool at least 2 minutes before 
refueling.

Equipment must be used on a hard, level surface, free from grease, fuel and other combustible materials.

Engine must not be run at excessive speeds.  Operating an engine at excessive speeds increases the hazard of personal 
injury. 

 Do not tamper with the parts which may increase or decrease the speed of the engine.

Do not operate this generator in the rain or unusually wet conditions.

This generator is designed for outdoor use only; do not use this generator inside any building or enclosure including the 
generator compartment of a recreational vehicle (RV), garages, basements, crawl spaces and other locations where CO 
gas can collect and cause death or injury. Fire or an explosion may result.

No user-performed modifications, including venting of exhaust and/or cooling ventilation are authorized by the 
manufacturer,   Also, allow at least two feet of clearance on all sides of the generator even while operating the unit 
outdoors.

If this unit is used for backup power in the event of a utility power failure, the following step must be taken:  Before 
connecting the generator to an electrical system, open the main circuit breaker or main switch serving the system, to 
isolate the generator system from the electric utility.  Failure to isolate the generator and utility systems may result in 
damage to the generator and may also result in injury or death to electric utility workers, due to a back feed of electrical 
energy.

This product is equipped with a spark-arresting muffler.  If the product will be used around flammable materials, or on land 
covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then the approved spark 
arrester must be installed.  SPARK-ARRESTERS ARE REQUIRED IN THE STATE OF CALIFORNIA.  Spark arresters are 
also required on some U.S. Forest Service land and may also be legally required under other statutes and ordinances.

Never step over a generator.

Failure to heed these warnings may result in personal injury and/or property damage. No modifications, alterations, or 
deviations to the generator are authorized by the manufacturer and should not be made.

Engine speed has been factory set to provide safe operation.  Tampering with the engine speed adjustment could result in 
overheating of attachments and could cause a fire.  Never attempt to “speed up” the engine to obtain more performance.  
Both the output voltage and frequency will be thrown out of standard by this practice, endangering attachments and the 
user.

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

DANGER
WARNING

1

Содержание C41155

Страница 1: ...e must not be run at excessive speeds Operating an engine at excessive speeds increases the hazard of personal injury Do not tamper with the parts which may increase or decrease the speed of the engin...

Страница 2: ...GENERATOR 1 Generator 2 6 ft Battery Cable 3 Wheel Kit 1 Axle 2 Wheels 2 Vibration Mounts 1 Handle Assembly 1 Support Leg 4 Bolt Kit 2 Wheel Retaining Pins 2 Flat Washers 10 Cap Screws and Nuts 5 Spar...

Страница 3: ...ator or engine 1 AC Voltmeter Use the voltmeter as a visual aid It indicates the AC voltage The normal voltage meter reading is 230 to 250 volts resulting in proper distribution of voltage to the rece...

Страница 4: ...Hand Drill Hand Drill 1 4 Hand Drill 3 8 Hedge Trimmer Home Security Impact Wrench Jet Pump Jigsaw Lawn Mower Light Bulb Microwave Milk Cooler Oil Burner on Furnace Oil Fired Space Heater 140 000 BTU...

Страница 5: ...ecure the wheel with a retaining pin Fig 3 d Install the other wheel in the same manner 3 Secure each vibration mount to the support leg with a lock nut M8 and a cap screw M8 x 30 Fig 4 4 Secure the s...

Страница 6: ...fore it has been properly filled with the recommended oil may result in engine failure Add gasoline 1 Use regular UNLEADED gasoline with the generator engine Do not use premium gasoline Do not mix oil...

Страница 7: ...er foreign material 3 Check the cleanliness of the generator frequently and clean when dust dirt oil moisture or other foreign substances are visible on its exterior surface 4 Check the oil level and...

Страница 8: ...op of the threads when on a level surface MAXIMUM FILL MINIMUM FILL DRAIN PLUG DIP STICK CAUTION This engine is equipped with a low oil shut off and the engine will stop when engine oil falls below th...

Страница 9: ...and workmanship for a period of one 1 year from the original date of purchase 90 days for commercial industrial use This warranty only applies to the original purchaser and is not transferable Do not...

Страница 10: ...s Road Santa Fe Springs CA 90670 Tel 562 236 9422 The emission warranty is a defects warranty Defects are judged on normal engine performance The warranty is not related to an in use emission test EMI...

Страница 11: ...l Metering System Air Induction System Ignition System Exhaust System Miscellaneous Parts Evaporative Emissions Fuel regulator Carburetor and internal parts Air cleaner Intake manifold Spark plug and...

Страница 12: ...PARTS DIAGRAM 12...

Страница 13: ...D 1160400 ST188FD 1160001 ST168F 1160500 ST168FD 1160200 GB819 85 ST168FD 1160100 GB5789 86 GB287 86 ST188FD 1160300 C ST188FD 1131001 Part Switch Control Panel A C 25A Circuit Breaker A C 20A Circuit...

Страница 14: ...D 1100103 GB5789 86 ST188FD 1100006 GB5789 86 ST188FD 1740004 C ST188FD 1740005 C ST188FD 1740100 C GB97 1 85 GB T91 2000 GB5789 86 Part Clip Valve Rubber tube Screw M5 x 10 Diaphram assembly Packing...

Отзывы: