Champion Power Equipment 42431 Скачать руководство пользователя страница 6

Manual Conventions 

2  

Rev 

42431-20090227

 

Manual Conventions 

This manual uses the following symbols to 

help differentiate between different kinds of 
information. The safety symbol is used with 

a key word to alert you to potential hazards 
in operating and owning power equipment. 

 

Follow all safety messages to avoid or reduce 
the risk of serious injury or death. 

 DANGER 

DANGER indicates an imminently hazardous 
situation which, if not avoided, 

will

 result in death 

or serious injury.  
 

 

 WARNING 

WARNING indicates a potentially hazardous 
situation which, if not avoided, 

could

 result in 

death or serious injury.  
 

 CAUTION 

CAUTION indicates a potentially hazardous 
situation which, if not avoided, 

may

 result in 

minor or moderate injury. 
 

 

CAUTION 

CAUTION used without the safety alert symbol 
indicates a potentially hazardous situation which, 
if not avoided, 

may

 result in property damage. 

 

 

  NOTE 

If you have questions regarding your generator, 
we can help. Please call our help line at 1-877-
338-0999. 
 

 

Содержание 42431

Страница 1: ...Fe Springs Road Santa Fe Springs CA 90670 USA Made in China 1500 Peak Watts 1200 Running Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual Owne...

Страница 2: ......

Страница 3: ...intenance 12 Engine Maintenance 12 Oil 12 Spark Plug 12 Air Filter 12 Spark Arrester 13 Cleaning 13 Adjustments 13 Maintenance Schedule 13 Generator Maintenance 13 Storage 14 Engine Storage 14 Generat...

Страница 4: ......

Страница 5: ...ories Champion Power Equipment manufactures and sells accessories designed to help you get the most from your purchase To find out more about our covers power cables and storm kits please visit our we...

Страница 6: ...minently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serio...

Страница 7: ...Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator produces powerful voltage DO NOT touch bare wires or...

Страница 8: ...away from sparks open flames pilot lights heat and other sources of ignition WARNING Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go Unintent...

Страница 9: ...alve Turn this valve to the On position to supply fuel to the engine 3 Choke Lever Used to start the engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil...

Страница 10: ...r 2 Intelligauge Three mode digital meter for running hours voltage and hertz 3 120 V 20 A Receptacle This receptacle powers 120 Volt AC single phase 60 Hz loads requiring up to 1200 Watts of power Pr...

Страница 11: ...20090227 7 Parts Included Your 42431 Gasoline Powered Generator ships with the following parts Spark Arrester Kit Spark Arrester 1 piece Cover Plate 1 piece Screws Lock Washers 2 pieces Oil Funnel 1...

Страница 12: ...reen with the lettering facing outward Secure the cover plate with the two screws and lock washers provided with the spark arrester kit Add Engine Oil CAUTION DO NOT attempt to crank or start the engi...

Страница 13: ...on DO NOT fill fuel tank indoors DO NOT fill fuel tank when the engine is running or hot DO NOT overfill the fuel tank DO NOT light cigarettes or smoke when filling the fuel tank Grounding Your genera...

Страница 14: ...uipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations 2 Obtain an Uninterruptible Power Supply UPS devic...

Страница 15: ...e 3 Plug in and turn on the first item It is best to attach the item with the largest load first 4 Allow the engine to stabilize 5 Plug in and turn on the next item 6 Allow the engine to stabilize 7 R...

Страница 16: ...ly 3 Replace the drain plug 4 Remove oil fill cap dipstick to add oil 5 Add 0 42 qt 0 4 L of oil and replace oil fill cap dipstick 6 Dispose of used oil at an approved waste management facility Spark...

Страница 17: ...act our help line at 1 877 338 0999 to locate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenance needs Every 8 hours or daily Check oil level Clean...

Страница 18: ...ompletely from the fuel line and carburetor to prevent gum from forming 4 Add a fuel stabilizer into the fuel tank 5 Change the oil 6 Remove the spark plug and pour about ounce of oil into the cylinde...

Страница 19: ...4 5 L Use regular unleaded gasoline with a minimum octane rating of 85 Oil Oil capacity is 0 42 qt 0 4 L Spark Plugs Your generator comes equipped with a 1 2 long reach plug 12 7mm Intermittent use l...

Страница 20: ...Specifications 16 Rev 42431 20090227 Parts Diagram...

Страница 21: ...S5 12 Screw M5x12 2 23 ST02FD 1151201 Build up 1 24 ST02FD 05212007 Conduit 1 25 ST02FD 1151201 Build up 1 26 GB41 N 6 Nut M6 1 27 ST02FD 1151207 M Grounding Wire 1 28 ST154FD 2000003 Motor Mount C Re...

Страница 22: ...D Fuel Tank Wing 2 54 ST154FD 3000005 Alternator Front Frame 1 55 GB5789 FB8 20 Flange Bolt M8 20 4 56 ST154FD 3001000 Rotor Comp 1 57 ST154FD 3000006 Stator Cover 1 58 ST154FD 3002000 Stator Assembl...

Страница 23: ...Specifications Rev 42431 20090227 19 Wiring Diagram...

Страница 24: ...ply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable...

Страница 25: ...ole Installation Use and Maintenance This warranty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the gene...

Страница 26: ...ng diagnosis parts and labor MANUFACTURER S EMISSION CONTROL SYSTEM WARRANTY COVERAGE This emission control system is warranted for two years subject to provisions set forth below If during the warran...

Страница 27: ...ired or replaced under the ECS Warranty shall be warranted for any remainder of the ECS Warranty Period b Any warranted emissions related part which is scheduled only for regular inspection as specifi...

Страница 28: ...gs Seals Gaskets and Clamps associated with these listed systems Evaporative Emissions Fuel Tank Fuel Cap Fuel Line Fuel Line Fittings Clamps Pressure Relief Valves Control Valves Control Solenoids El...

Страница 29: ...Notes Rev 42431 20090227 25 Notes...

Отзывы: