REV 41151-20140108
6
41151
ENGLISH
Power Panel
CONTROLS AND FEATURES
(1) Engine Switch
– Flip the switch to the “On”
position and pull the recoil starter to start the
generator. Turn to the “Off” position to turn off the
generator.
(2) Circuit Breakers
– Protects the generator against
electrical overload.
(3) Voltmeter
– Displays the output voltage of the
generator.
(4) 120V, 30A Twist-Lock
– (NEMA L5-30R) May be
used to supply electrical power for the operation of
120 Volt AC, 60 Hz, single phase loads.
(5) 120/240V, 30 A Twist-Lock
– (NEMA L14-30R)
May be used to supply electrical power for the
operation of 120/240 Volt AC, 30 Amp, single
phase 60 Hz electrical loads.
(6) 120V AC, 20 Amp Duplex
– (NEMA 5-20R)
May be used to supply electrical power for the
operation of 120 Volt AC, 20 Amp, single phase
60 Hz electrical loads.
(7) Ground Terminal
– Consult an electrician for local
grounding regulations.
2
1
3
4
5
6
7