201182 - 7500W WIRELESS REMOTE START GENERATOR
TROUbLESHOOTING
34
TROUbLESHOOTING
Problem
Cause
Solution
Engine will not start.
No fuel.
Add fuel.
Faulty spark plug.
Clean and adjust spark plug or replace.
Low oil level.
Fill crankcase to the proper level.
Place generator on a flat, level surface.
Spark plug wire loose.
Attach wire to spark plug.
Fuel valve is closed.
Open fuel valve.
Ignition switch OFF.
Press ignition switch ON.
Old fuel or water in fuel.
Drain fuel and replace with fresh fuel.
Flooded with fuel.
Let unit stand for 10 mins.
CO Shield
®
module has been removed or
tampered with.
Re-install module or contact technical support.
Engine starts but runs roughly.
Choke lever in the wrong position.
Move choke lever until it stops under “RUN”
position or push in completely.
Dirty air filter.
Clean or replace air filter.
Dirty fuel valve.
Clean the fuel valve.
Clogged spark arrestor.
Clean spark arrestor.
Engine will not start wirelessly.
Remote control battery is dead.
Replace remote control battery.
Generator battery is dead.
Recharge generator battery.
Battery switch is in the OFF position.
Turn battery switch to ON position.
Generator out of range of remote signal. Remote must be with 80 feet of generator.
Obstructions in between generator and
remote.
Clear line of site between generator and remote.
Engine will not start electrically.
Generator battery is dead.
Recharge generator battery.
Battery switch is in the OFF position.
Turn battery switch to ON position.