Champion Power Equipment 100519 Скачать руководство пользователя страница 24

100519 - 6250W OPEN FRAME INvERTER

MAINTENANCE

24

Changing the Engine Oil

Change oil when the engine is warm. Refer to the oil 
specification to select the proper grade for your operating 
environment.

1.  Unclip the quick drain oil tube from behind the panel and 

remove the oil drain cap.

2.  Allow the oil to drain completely into an appropriate 

container.

3.  Replace the oil drain cap.

4.  Remove the oil fill cap/dipstick to add oil.

5.  Add oil according to “Add Engine Oil” on Assembly 

section. DO NOT OVERFILL. Oil not included for routine 
maintenance.

6.  Dispose of used oil at an approved waste management 

facility.

 

NOTICE

Once oil has been added, a visual check should show oil 
about 1-2 threads from running out of the fill hole. If using 
the dipstick to check oil level, DO NOT screw in the dipstick 
while checking.

Cleaning and Adjusting the Spark Plug

1.  Remove the spark plug cable from the spark plug.

2.  Use a spark plug socket tool (not included), or a 

13/16 in. (21 mm) socket (not included) to remove the plug.

3.  Inspect the electrode on the plug. It must be clean and not 

worn to produce the spark required for ignition.

4.  Make certain the spark plug gap is 

0.028-0.031 in. (0.7-0.8 mm).

SPARK PLUG GAP

5.  Refer to the spark plug types in 

Specifications

 when 

replacing the plug.

6.  Firmly re-install the plug.

7.  Attach the spark plug cable to the spark plug.

Cleaning the Air Filter

1.  Remove the snap-on cover holding the air filter to the 

assembly.

2.  Remove the foam element. 

3.  Wash in liquid detergent and water. Squeeze thoroughly dry 

in a clean cloth.

4.  Saturate in clean engine oil. 

5.  Squeeze in a clean, absorbent cloth to remove all excess 

oil.

6.  Place the filter in the assembly.

7.  Reattach the air filter cover and snap in place.

Содержание 100519

Страница 1: ...ns important safety precautions which should be read and understood before operating the product Failure to do so could result in serious injury This manual should remain with the product Specificatio...

Страница 2: ...the Engine 19 Connecting Electrical Loads 20 Do Not Overload Generator 20 GFCI 21 Eco Economy Mode 21 12V DC Automotive Style Outlet 21 Stopping the Engine 22 Operation at High Altitude 22 Moving the...

Страница 3: ...s exercise common sense and always err on the side of caution when operating the product to ensure no accident property damage or injury occurs We want you to continue to use and be satisfied with you...

Страница 4: ...g parts can entangle hands feet hair clothing and or accessories Traumatic amputation or severe laceration can result Keep hands and feet away from rotating parts Tie up long hair and remove jewelry D...

Страница 5: ...result When starting engine pull the starter cord slowly until resistance is felt and then pull rapidly to avoid kickback DO NOT start or stop the engine with electrical devices plugged in and turned...

Страница 6: ...m the gasoline tank Only fill or drain gasoline outdoors in a well ventilated area DO NOT pump gasoline directly into the generator at the gas station Always use an approved fuel container to transfer...

Страница 7: ...K 109 Colors LPN 1110 L OP Rev B Size 46 x 46 mm Artwork Notes 3mm corner radius 2mm safe margin white to be printed shown in 50 process magenta Revision Changes Changed Octane rating from 85 to 87 20...

Страница 8: ...re operation Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Improper connections to a building can allow current to backfeed into utility li...

Страница 9: ...you to more safely operate the product SYMBOL MEANING ON STOP or OFF Choke Pull choke knob to CHOKE position Run Push choke knob to RUN position AC Reset Output OK Overload ECO Economy Mode Switch SY...

Страница 10: ...ed by or for outside parties without the explicit consent of Champion Power Equipment K 376 186 152 CG1 2945 Colors Starting the Engine DANGER Move generator outside and far away from windows doors an...

Страница 11: ...to lift or carry the unit 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Filter Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used to manuall...

Страница 12: ...down and not run Check oil level 9 Circuit Breakers Push Reset Protects the generator against electrical overloads RECEPTACLES A z 12V DC 8 Amp Automotive May be used to supply electrical power for op...

Страница 13: ...rtz Example 60 0 hertz Run Time R Run time of the generator for the current session Example 6 hours Total Run Time Total run time of the generator since first operation Example 16 hours Intelligauge F...

Страница 14: ...accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment do...

Страница 15: ...r NOTICE DO NOT attempt to run generator without first removing the shipping support brackets Damage to the generator as a result of not removing the brackets will void the warranty 1 BEFORE filling t...

Страница 16: ...chart for recommended oil type 20 0 20 40 60 Ambient temperature Recommended Engine Oil Type 80 100 120 28 9 F C 17 8 6 7 4 4 15 6 26 7 37 8 48 9 10W 30 5W 30 Full Synthetic 10W 40 5W 30 1 Place the...

Страница 17: ...n expand after filling A minimum of in 6 4 mm of space left in the tank is required for gasoline expansion although more than in 6 4 mm is recommended Gasoline can be forced out of the tank as a resul...

Страница 18: ...n will not function if the receptacle ground pin is not functional Neutral Bonded to Frame Neutral circuit IS electrically connected to the frame ground of the generator The generator system ground co...

Страница 19: ...come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Starting the Engine 1 Make certain the generator is on a flat level surface...

Страница 20: ...enerator during an outage please notify your electric utility company immediately and remember to plug your appliances directly into the generator Do not plug the generator into any electric outlet in...

Страница 21: ...he receptacle to restore the flow of electricity If the indicator light does not come back on or if the GFCI cannot be reset then it must be replaced B C A Eco Economy Mode The Eco Mode switch can be...

Страница 22: ...enerator Stopping the Engine 1 Turn off and unplug all electrical connected loads Never start or stop the generator with electrical devices plugged in or turned on 2 Let the generator run at no load f...

Страница 23: ...slightly off the ground until balanced on the wheels 3 While maintaining balance roll the generator to the desired location NEVER tilt sideways while moving the generator Failure to follow these inst...

Страница 24: ...evel DO NOT screw in the dipstick while checking Cleaning and Adjusting the Spark Plug 1 Remove the spark plug cable from the spark plug 2 Use a spark plug socket tool not included or a 13 16 in 21 mm...

Страница 25: ...is equipped with a spark arrestor Adjusting the Governor WARNING Tampering with the factory set governor will void your warranty The air fuel mixture is not adjustable Tampering with the governor can...

Страница 26: ...o the OFF 5c Use the drain bolt on the carburetor to empty any excess gasoline from the carburetor into an appropriate container Use a funnel and appropriate hose if necessary under the carburetor dra...

Страница 27: ...emoving from storage 1 Be sure the engine switch is in the OFF position 2 Add gasoline to the generator according to Add Fuel Gasoline 3 Turn the fuel valve to the ON position 4 After 5 minutes check...

Страница 28: ...ature Recommended Engine Oil Type 80 100 120 28 9 F C 17 8 6 7 4 4 15 6 26 7 37 8 48 9 10W 30 5W 30 Full Synthetic 10W 40 5W 30 NOTICE Temperature will affect engine oil and engine performance Change...

Страница 29: ...Generator is overloaded Review load and adjust See Connecting Electrical Loads Dirty air filter Clean or replace air filter Choke in wrong position Move choke until it stops under RUN position or pus...

Страница 30: ...beyond the product s limits modified installed improperly or connected incorrectly to any electrical component Normal maintenance is not covered by this warranty and is not required to be performed a...

Страница 31: ...condition exits CPE will repair your small off road engine SORE and equipment at no cost to you including diagnosis parts and labor MANUFACTURER S WARRANTY COVERAGE This Emissions Control System is w...

Страница 32: ...shall be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replace...

Страница 33: ...Mounting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other p...

Отзывы: