background image

OPERATOR'S MANUAL

MODEL #200990

4500W WIRELESS REMOTE

START INVERTER GENERATOR

Champion Power Equipment, Inc., Santa Fe Springs, CA USA

or visit 

championpowerequipment.com

SAVE THESE INSTRUCTIONS.

 This manual contains important safety precautions which should be read and understood before operating the product. Failure to do 

so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
This product meets the requirements of the PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2015 (Safety and Performance of 
Portable Generators).

REGISTER YOUR PRODUCT ONLINE

at 

championpowerequipment.com

REV 20201019

Содержание 200990

Страница 1: ...the product Failure to do so could result in serious injury This manual should remain with the product Specifications descriptions and illustrations in this manual are as accurate as known at the time of publication but are subject to change without notice This product meets the requirements of the PGMA Portable Generator Manufacturers Association standard ANSI PGMA G300 2015 Safety and Performanc...

Страница 2: ...t all carbon monoxide risks you ll be better prepared to protect your family from this colorless oderless threat CARBON MONOXIDE SAFETY THE BIG PICTURE KNOW THE SYMPTOMS Headache Nausea Shortness of breath Dizziness Fatigue STAY ALERT WITH CARBON MONOXIDE DETECTORS POINT FUMES AWAY FROM NEARBY PEOPLE KEEP IT OUTSIDE AND AWAY FROM DOORS WINDOWS AND GARAGES ALWAYS READ THE OPERATOR S MANUAL FIRST MA...

Страница 3: ... Generator 27 Eco Economy Mode 28 Parallel Operation 28 Stopping the Engine 28 Moving the Generator 29 Operation at High Altitude 30 Maintenance 30 Cleaning the Generator 30 Changing the Engine Oil 31 Cleaning and Adjusting the Spark Plug 31 Cleaning the Air Filter 31 Cleaning the Spark Arrestor 32 Generator Battery 32 Remote Key Fob Battery 33 Adjusting the Governor 33 Maintenance Schedule 33 Sto...

Страница 4: ...ce Every effort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this document at any time without prior notice CPE highly values how our products are designed manufactured operated and serviced as well as providing safety to the operator and those around the ge...

Страница 5: ...ace Rotating parts can entangle hands feet hair clothing and or accessories Traumatic amputation or severe laceration can result Keep hands and feet away from rotating parts Tie up long hair and remove jewelry DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator produces powerful voltage DO NOT touch bare wires or receptacles DO NOT use electri...

Страница 6: ...n result in entanglement traumatic amputation or laceration When starting engine pull the recoil cord slowly until resistance is felt and then pull rapidly to avoid kickback DO NOT start or stop the engine with electrical devices plugged in and turned on CAUTION Exceeding the generator s running capacity can damage the generator and or electrical devices connected to it DO NOT overload the generat...

Страница 7: ...ine directly into the generator at the gas station Always use an approved container to transfer the fuel to the generator DO NOT overfill the gasoline tank Always keep gasoline away from sparks open flames pilot lights heat and other sources of ignition When starting the generator DO NOT attempt to start a damaged generator Always check that the gasoline cap air filter spark plug fuel lines and ex...

Страница 8: ...y sitting for 0 5 to 1 hour before checking the voltage If the voltage is less than 12 8V additional charging is necessary If the battery becomes hot to the touch stop charging Allow battery to cool before resuming When storing the generator battery Always check that the battery connectors between the inverter and the battery are unplugged and placed away from the battery terminals Always inspect ...

Страница 9: ...elongs to Champion Power Equipment The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment Fuel C CHAMPION POWER EQUIPMENT INC 12039 SMITH AVENUE SANTA FE SPRINGS CA 90670 USA É U 1 877 338 0999 WWW CHAMPIONPOWEREQUIPMENT COM MADE IN CHINA FABRIQUÉ EN CHINE AC AMPS AMPÈRES C A FREQUENCY Hz...

Страница 10: ...lines creating an electrocution hazard A transfer switch must be used when connecting to a building Fire Explosion Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death Keep generator at least 5 feet 1 5m from all objects to prevent combustion Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Open Flame Alert...

Страница 11: ...sult your local waste authority for information regarding available recycling and or disposal options Blindness or severe burns Electrolyte solution can cause blindness or severe burns Shield eyes Explosive gases can cause blindness or injury If damaged battery may emit hazardous fumes If fumes present move battery to a well ventilated area Eye protection Always wear eye protection with side shiel...

Страница 12: ...roduct SYMBOL MEANING Start On Stop or Off Choke Run USB Connection Port 5V Direct Current Battery On Battery Off Neutral Floating Neutral circuit IS NOT electrically connected to the frame ground of the generator Circuit Breaker Reset Push SYMBOL MEANING RV Ready Receptacle Ground Terminal Parallel Connection s ECO Economy Mode Button Overload Reset Button Low Oil Wireless Pair Gasoline Tank Full...

Страница 13: ...t consent of Champion Power Equipment K 376 186 152 CG1 300 Starting the Engine DANGER Move generator outside and far away from windows doors and intake ventilation covers 1 Check oil level Recommended oil is 10W 30 2 Check gasoline level When adding gasoline use a minimum octane rating of 87 and an ethanol content of 10 or less by volume 3 Turn battery switch to the ON position 4 Turn the EZ Star...

Страница 14: ... for future reference Generator 1 Folding Handle Used to move unit by lifting and rolling on wheels Do not use to lift or carry the unit 2 Fuel Cap Remove to add fuel 3 Fuel Gauge 4 Battery Access Cover 5 Control Panel See Control Panel section 6 Recoil Starter Used to manually start the engine 7 Never Flat Wheels 5 in 12 7 cm 8 Oil Fill Access Cover 9 Carrying Handle s Used to lift or carry the u...

Страница 15: ...und Terminal Consult an electrician for local grounding regulations 7 Parallel Outlets Used to parallel two inverters together for increased power output parallel kit sold separately RECEPTACLES A A 2 120V AC 20A NEMA 5 20R May be used to supply electrical power for operation of 120 Volt AC 20 Amp single phase 60 Hz electrical loads B t 120V AC 30A RV NEMA TT 30R May be used to supply electrical p...

Страница 16: ...ime of the generator for the current session Example 6 hours Total Run Time Total run time of the generator since first operation Example 16 hours Power Meter Power Output percentage Example 100 Output Intelligauge with Power Meter The meter is divided into two seperate displays The LCD displays each mode for several seconds and then automatically cycles through The Power Meter LED displays output...

Страница 17: ...ery Switch to the OFF position This disconnects power to the RCM so there is no current draw on the battery FCC Statement for Remote Control Device 1 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1a This device may not cause harmful interference 1b This device must accept any interference received including interference that may cause undes...

Страница 18: ...Start Inverter Generator Controls and Features 18 Parts Included Accessories Engine Oil 16 9 fl oz 500 ml Oil Funnel 1 Remote Key Fob 1 Tools Included 8 10 mm Wrench 1 Spark Plug Socket 1 Reversible Phillips Flathead Screwdriver 1 ...

Страница 19: ... or other protective surface so as to not scratch the enclosure 2 Remove the four nuts and mounting plates from the bottom side of the generator using the included 8 10 mm wrench Nuts and spacers can be discarded 3 Tip the generator upright Connect the Battery 1 Remove the non recoil side maintenance cover by removing the two screws with a phillips head screw driver not included 2 Push two halves ...

Страница 20: ...ours of run time are the break in period for the unit During the break in period stay at or below 50 of the running watt rating and vary the load occasionally to allow stator windings to heat and cool Adjusting the load will also cause engine speed to vary slightly and help seat piston rings After the 5 hour break in period change the oil NOTICE Synthetic oil may be used after the 5 hour initial b...

Страница 21: ... 6 4 mm below the top of the tank to allow for gasoline expansion DO NOT pump gasoline directly into the generator at the pump Use an approved fuel container to transfer the gasoline to the generator DO NOT fill tank indoors DO NOT fill tank when the engine is running or hot WARNING Pouring gasoline too fast through the fuel screen may result in gasoline splashing over the generator and operator w...

Страница 22: ... back of an SUV camper trailer truck bed regular sides flat or other configuration under staircases stairwells next to walls or buildings or in any other location that will not allow for adequate cooling of the generator or for the proper exit of the exhaust flow from the muffler system DO NOT operate or store the generator in wet weather conditions such as rain or snow Using a generator in wet co...

Страница 23: ...ke steps to protect sensitive electronic equipment Install UL1449 CSA listed plug in surge suppressors on the outlets feeding your sensitive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Wireless Set Button The wireless set button is a feature that lets the user synchronize the remote key fob ...

Страница 24: ... the battery proceed with Wireless Set Button instructions Starting the Engine 1 Make certain the generator is on a flat level surface Wireless Remote Start Wireless remote starting is only possible within 80 feet of the generator DO NOT attempt to adjust the choke The remote system will automatically close and open the choke 1 Push the battery switch to the ON position 2 Turn the EZ Start Dial to...

Страница 25: ...ase the switch and wait at least ten seconds before attempting to start the engine again 6 Do not over choke As soon as engine starts push the choke button one time to set the choke to the RUN position Choke button will no longer be illuminated when in RUN position CAUTION If the ignition switch is held down in the START position longer than 5 seconds it could damage the starter Manual Start 1 Dis...

Страница 26: ... engine starts but does not run make certain that the generator is on a flat level surface The engine is equipped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold Manual Choke Start If the battery is dead or not able to produce enough current to power the push button choke the choke itself can be operated manually to help start the...

Страница 27: ...s and could cause serious injury or death to you or a utility worker when attempting to restore power during an outage occurrence in the neighborhood who may then unexpectedly encounter high voltage on the utility line and suffer a fatal shock Whether injuries occur or not if installed incorrectly and not to applicable laws and codes you may be subject to fines or the utility company may disconnec...

Страница 28: ...omy control in order to minimize fuel consumption and noise while operating the unit during times of reduced electrical output Eco Mode allows the engine speed to idle during periods of non use The engine speed returns to normal when an electrical load is connected When the economy switch is off the engine runs at normal speed continuously CAUTION For periods of high electrical load or momentary f...

Страница 29: ...n at no load for several minutes to stabilize internal temperatures of the engine and generator 3 Turn the EZ Start Dial to the OFF position 4 If battery switch is in the ON position press the battery switch to the OFF position Important Always ensure that the EZ Start Dial and battery switch are in the OFF position when the generator will not be used for an extended period of time NOTICE If the e...

Страница 30: ...16161 Z140310 0000 6000 ft 1829 m WARNING Operation using the alternative main jet at elevations lower than the recommended minimum altitude can damage the engine For operation at lower elevations the originally supplied standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance...

Страница 31: ...d a visual check should show oil about 1 2 threads from running out of the fill hole If using the dipstick to check oil level DO NOT screw in the dipstick while checking Cleaning and Adjusting the Spark Plug 1 Remove the non recoil side maintenance cover by removing the two screws with a phillips head screw driver included 2 Remove the spark plug cable from the spark plug 3 Use a spark plug socket...

Страница 32: ...l and local laws and administrative requirements indicate when and where spark arrestors are required When ordered spark arrestors are required for operation of this generator in National Forest lands In California this generator must not be used on any forest covered land brush covered land or grass covered land unless the engine is equipped with a spark arrestor Generator Battery Your generator ...

Страница 33: ...ys purchase the correct size and grade of battery most suitable for the intended use Clean the battery contacts and also those of the device prior to battery installation Remove batteries from equipment which is not to be used for an extended period of time Remove batteries if consumed or if product is to be left unused for a long time Adjusting the Governor WARNING Tampering with the factory set ...

Страница 34: ...gine run until fuel starvation has stopped the engine 6 After the engine stops turn the EZ Start dial counterclockwise to the STOP position 7 After fuel has run out and the engine has stopped allow the engine to cool 8 Remove the non recoil side maintenance cover by removing the two screws with a phillips head screw driver included 9 Remove the spark plug and pour about a tablespoon of oil into th...

Страница 35: ...g from storage 1 Be sure the EZ Start dial is in the STOP position 2 Add gasoline to the generator according to Add Fuel 3 Move the EZ Start dial to the ON position 4 After 5 minutes check the carburetor and air filter areas for any leaking gasoline If any leaks are found the carburetor will need to be disassembled and cleaned or replaced If no gasoline leaks are found turn the EZ Start dial to th...

Страница 36: ... 8 48 9 10W 30 5W 30 Full Synthetic 10W 40 5W 30 NOTICE Temperature will affect engine oil and engine performance Change the type of engine oil used based on temperature shown in the Recommended Engine Oil Type table Fuel Specifications Use unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10 or less by volume DO NOT USE E15 or E85 DO NOT OVERFILL Gasoline Capacity 2 3...

Страница 37: ... position Turn battery switch to ON position Generator out of range of remote signal Remote must be with 80 feet of generator Obstructions in between generator and remote Clear line of site between generator and remote Engine will not start electrically Generator battery is dead Start manually and allow battery to recharge or see Charge the Battery Section Battery switch is in the OFF position Tur...

Страница 38: ...ng position Press choke button until no longer illuminated green If battery is dead turn choke lever to the RUN position Repeated circuit breaker tripping Overload Review load and adjust See Connecting Electrical Loads Faulty power cords or device Check for damaged bare or frayed wires Replace defective device Circuit breaker still too hot Let unit sit for 5 mins For other issues and technical sup...

Страница 39: ... improperly or connected incorrectly to any electrical component Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by CPE Other Exclusions This warranty excludes Cosmetic defects such as paint decals etc Wear items such as filter elements o rings etc Accessory parts such as starting batteries and storage covers Failures d...

Страница 40: ...e condition exits CPE will repair your small off road engine SORE and equipment at no cost to you including diagnosis parts and labor MANUFACTURER S WARRANTY COVERAGE This Emissions Control System is warranted for two years If any emissions related part on your small off road engine SORE and equipment is defective the part will be repaired or replaced by CPE OWNER WARRANTY RESPONSIBILITIES As the ...

Страница 41: ...l shall be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CPE according to Subsection d below Any such emissions related part repaired or replaced under the ECS Warranty shall be warranted for a time not less than the remainder of the ECS Warranty Peri...

Страница 42: ... Mounting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of original purchase date at your expense to any Champion Power Equipment dealer who is authorized by Champion Power Equipment Inc to sell and service that CPE product during his normal business...