100891 - 7500W DUAL FUEL PORTAbLE GENERATOR
OPERATION
21
Electric Start
5. Press and hold the ignition switch to the “START” position.
Release as the engine begins to start. If the engine fails to
start within five seconds, release the switch and wait at least
ten seconds before attempting to start the engine again.
CAUTION
If the ignition switch is held down in the “START” position
longer than 5 seconds it could damage the starter.
6. When engine starts running, move choke lever slowly to the
“RUN” position over a 2-5 second period.
7. Plug in devices.
CAUTION
If the ignition switch is held down in the “START” position
longer than 5 seconds it could damage the starter.
Manual Start
5. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.
6. When engine starts running, move choke lever slowly to the
“RUN” position over a 2-5 second period.
7. Plug in devices.
NOTICE
Keep choke in “CHOKE” position for only 1 pull of the recoil
cord. After first pull, move choke to “RUN” position for up to
3 pulls of the recoil cord. Too much choke leads to spark plug
fouling/engine flooding due to lack of incoming air. This will
cause the engine not to start.
NOTICE
For gasoline restarts with hot engine in hot ambient >
86°F (30°C)
, keep choke in 75% of the “CHOKE” position for
only 1 pull of the recoil cord. After first pull, move choke to
“RUN” position for up to 3 pulls of the recoil cord. Too much
choke leads to spark plug fouling/engine flooding due to lack
of incoming air. This will cause the engine not to start.
NOTICE
For gasoline starting in cold ambient temperature < 59°F
(15°C),
the choke must be in 100% of the “CHOKE” position
for recoil cord procedures. Do not over-choke. As soon as
engine starts, gradually move the choke lever to the “RUN”
position over a 2-5 second duration.
NOTICE
If the engine starts but does not run make certain that the
generator is on a flat, level surface. The engine is equipped
with a low oil sensor that will prevent the engine from running
when the oil level falls below a critical threshold.