Diagnostic Chart

Safety reversing sensors 
slightly misaligned (dim 
or fl ashing LED).

Door control or wire 
shorted. 

Safety reversing sensors 
wire shorted or black/white 
wire reversed. 

Safety reversing sensors 
wire open (broken or 
disconnected). 

OR

Symptom: One or both of the Indicator lights on the safety sensors do not glow 
steady.

•   Inspect sensor wires for a short (staple in wire), correct wiring polarity (black/

white wires reversed), broken or disconnected wires, replace/attach as needed.

•  Disconnect all wires from back of motor unit.

•   Remove sensors from brackets and shorten sensor wires to 1-2 ft (30-60 cm) 

from back each of sensor.

•   Reattach sending eye to motor unit using shortened wires. If sending eye 

indicator light glows steadily, attach the receiving eye. 

•   Align sensors, if the indicator lights glow replace the wires for the sensors. If the 

sensor indicator lights do not light, replace the safety sensors.

Symptom: LED is not lit on door control.

•  Inspect door control/wires for a short (staple in wire), replace as needed.

•   Disconnect wires at door control, touch wires together. If motor unit activates, 

replace door control.

•   If motor unit does not activate, disconnect door control wires from motor unit. 

Momentarily short across red and white terminals with jumper wire. If motor unit 
activates, replace door control wires.

Symptom: Sending indicator light glows steadily, receiving indicator light is dim 
or fl ashing.

•  Realign receiving eye sensor, clean lens and secure brackets. 

•  Verify door track is fi rmly secured to wall and does not move.

Symptom: Motor has overheated; the motor unit does not operate or trolley is 
stuck on stop bolt = Motor unit hums briefl y; RPM Sensor = Short travel 6-8" 
(15-20 cm). 

•  Unplug unit to reset. Try to operate motor unit, check diagnostic code.

•   If it is still fl ashing 5 times and motor unit moves 6-8" (15-20 cm), replace 

RPM sensor. 

•   If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and 

retry. If motor unit still will not operate replace logic board.

Symptom: Motor unit doesn’t operate.

•  Replace logic board because motor rarely fails.

1 FLASH

2 FLASHES

3 FLASHES

4 FLASHES

Your garage door opener is programmed with self-diagnostic 
capabilities. The “Learn” button/diagnostic LED will fl ash a 
number of times then pause signifying it has found a potential 
issue. Consult Diagnostic Chart below.

Motor overheated or 
possible RPM sensor 
failure. Unplug to reset.

5 FLASHES

Motor Circuit Failure. 
Replace Receiver 
Logic Board.

6 FLASHES

LED or 
Diagnostic 
LED 

“Learn” 
Button

Diagnostics 
Located On 
Motor Unit

Bell Wire

Safety Reversing Sensor

Installed 

Safety Reversing 

Sensor

Содержание WD822KD

Страница 1: ...ly Owner s Manual Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless The Protector System is c...

Страница 2: ...or control 31 To open the door manually 31 Care of your garage door opener 32 Having a problem 33 Diagnostic chart 34 Programming 35 36 To add or reprogram a hand held remote control 35 To erase all c...

Страница 3: ...call a trained door systems technician Tools needed During assembly installation and adjustment of the opener instructions will call for hand tools as illustrated below To prevent damage to garage do...

Страница 4: ...e oor and the bottom of the door must not exceed 1 4 6 mm Otherwise the safety reversal system may not work properly See Adjustment Step 3 Floor or door should be repaired SECTIONAL DOOR INSTALLATIONS...

Страница 5: ...or the garage door MUST be repaired to eliminate the gap ONE PIECE DOOR WITHOUT TRACK Header Wall Rail Gap between oor and bottom of door must not exceed 1 4 6 mm Safety Reversing Sensor Safety Rever...

Страница 6: ...SECURITY 3 Button Remote Control 2 2 Conductor Bell Wire White White Red Motor Unit with 2 Light Lenses Rail Front header Section Multi Function Door Control SECURITY Keyless entry Trolley Belt Idler...

Страница 7: ...Link 1 INSTALLATION HARDWARE Carriage Bolt 1 4 20x1 2 2 Wing Nut 1 4 20 2 Lag Screw 5 16 9x1 5 8 2 Screw 6ABx1 1 4 2 Lag Screw 5 16 18x1 7 8 2 Drywall Anchors 2 Self Threading Screw 1 4 14x5 8 2 Clev...

Страница 8: ...s shown and slide the tapered ends into the larger ones Tabs along the side will lock into place To prevent INJURY from pinching keep hands and ngers away from the joints while assembling the rail 3 P...

Страница 9: ...imately 12 30 cm of belt through the window Keep the ribbed side toward the rail and allow it to hang until Assembly Step 5 Remove the tape from the idler pulley The inside center should be pre grease...

Страница 10: ...in notches until both pins are securely locked in place 5 Insert the trolley threaded shaft through the hole in the trolley Be sure the belt is not twisted 6 Hold the belt at the trolley shaft as you...

Страница 11: ...installing opener 4 Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement 5 Install garage door opener 7 feet 2 13 m or more above oor 6 Mount...

Страница 12: ...or the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 13 for ceiling installation Header Wall Leve...

Страница 13: ...ATION Extend the vertical centerline onto the ceiling as shown Center the bracket on the vertical mark no more than 6 15 cm from the wall Make sure the arrow is pointing away from the wall The bracket...

Страница 14: ...e way you ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes a...

Страница 15: ...e with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to opene...

Страница 16: ...32x1 machine screws into gang box as follows Drill and install bottom screw allowing 1 8 3 mm to protrude above wall surface Position bottom of door control on screw head and slide down to secure Adju...

Страница 17: ...ssible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly NEVE...

Страница 18: ...ird grounding pin This plug will only t into a grounding type outlet If the plug doesn t t into the outlet you have contact a quali ed electrician to install the proper outlet If permanent wiring is r...

Страница 19: ...designed to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such...

Страница 20: ...oor no higher than 6 15 cm above the oor Attach brackets to wall with lag screws not provided If using extension brackets or wood blocks adjust right and left assemblies to the same distance out from...

Страница 21: ...sensors follow the instructions below Cut the end of the safety sensor wire making sure there is enough wire to reach the pre installed wires from the wall Figure 7 Separate the safety sensor wires a...

Страница 22: ...orrect wiring between sensors and opener A broken wire 2 If the sending eye indicator light glows steadily but the receiving eye indicator light doesn t Check alignment Check for an open wire to the r...

Страница 23: ...g holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washers and nuts not provided Figure 2B Metal insulated or light weight fac...

Страница 24: ...he door if required for your installation Refer to the dotted line optional placement drawing Self Threading Screw 1 4 14x5 8 Door Bracket Door Bracket Top of Door Inside Garage Header Wall Door Brack...

Страница 25: ...e holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that line up an...

Страница 26: ...d door adjustment decrease DOWN travel limit Turn the DOWN limit adjustment screw clockwise 4 complete turns Press the Door Control push button The trolley will travel to the fully closed position Man...

Страница 27: ...again NOTE If anything interferes with the door s upward travel it will stop If anything interferes with the door s downward travel including binding or unbalanced doors it will reverse HOW AND WHEN T...

Страница 28: ...verse HOW AND WHEN TO ADJUST THE FORCES 1 Test the DOWN close force Grasp the door bottom when the door is about halfway through DOWN close travel The door should reverse Reversal halfway through down...

Страница 29: ...e the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT...

Страница 30: ...r opener will operate with up to eight Security remote controls and one Security Keyless Entry System If you purchase a new remote or if you wish to deactivate any remote follow the instructions in th...

Страница 31: ...four blinks and 4 1 2 minutes Lock feature Designed to prevent operation of the door from hand held remote controls However the door will open and close from the Door Control the Outside Keylock and...

Страница 32: ...t the safety reverse test Adjustment Step 3 page 29 after any adjustment of limits or force MAINTENANCE SCHEDULE Every Month Manually operate door If it is unbalanced or binding call a trained door sy...

Страница 33: ...e following the instructions for Using the Multi Function Door Control Reprogram remotes following the programming instructions Refer to Programming If remote will still not activate your door check d...

Страница 34: ...nit Momentarily short across red and white terminals with jumper wire If motor unit activates replace door control wires Symptom Sending indicator light glows steadily receiving indicator light is dim...

Страница 35: ...remote controls To Add or Reprogram a Hand Held Remote Control USING THE LEARN BUTTON USING THE MULTI FUNCTION DOOR CONTROL 1 Press and hold the button on the hand held remote that you wish to operat...

Страница 36: ...t lights will blink once when the PIN has been learned Test by pressing the new PIN then press ENTER The door should move To set a temporary PIN You may authorize access by visitors or service people...

Страница 37: ...battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope and handle assembly 6 41B4494 1 2 Conductor bell wire white and white red 7 41A5047 1 Door bracket with clevis pin fastener...

Страница 38: ...bly RPM sensor KEY PART NO NO DESCRIPTION 11 41A5525 4 Cover 12 41A2818 Limit switch drive retainer 13 41D3452 Limit switch assembly 14 41A2822 1 Interrupter cup 15 41C4398A RPM sensor assembly 16 41A...

Страница 39: ...o operate garage door opener from outside by entering a password on a specially designed keyboard Also can add a temporary password for visitors or service persons This temporary password can be limit...

Страница 40: ...e defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with new or f...

Отзывы: