background image

The Chamberlain Group, Inc.
845 Larch Avenue
Elmhurst, Illinois 60126-1196

www.chamberlain.com

GARAGE DOOR OPENER

Models HD175DM 1/2 HP

HD150DM 1/3 HP

For Residential Use Only 

Owner’s Manual

   Please read this manual and the enclosed safety materials carefully!

  Fasten the manual near the garage door after installation.

   The door WILL NOT CLOSE unless The Protector System

®

 is connected and 

properly aligned.

   Periodic checks of the opener are required to ensure safe operation.

    The model number label is located on the front panel of your opener.

Содержание Security+ HD150DM

Страница 1: ...Only Owner s Manual Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless The Protector System is...

Страница 2: ...the trolley 8 Fasten the rail to the motor unit 9 Install the idler pulley 9 Install the chain cable 10 Tighten the chain 11 Installation 11 26 Installation safety instructions 11 Determine the heade...

Страница 3: ...Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding...

Страница 4: ...ng in your garage If so a support bracket and additional fastening hardware may be required Installation Step 10 Depending upon garage construction extension brackets or wood blocks may be needed to i...

Страница 5: ...ED CEILING Support bracket fastening hardware is required See page 16 Safety Reversing Sensor Header Wall Gap between floor and bottom of door must not exceed 1 4 6 mm Wall mounted Door Control Rail M...

Страница 6: ...ety Sensor Bracket 2 Motor Unit with a Light Lens Rail Center Back Sections Rail Front header Section Header Bracket Idler Pulley Chain Spreader Trolley U Bracket Your garage door opener is packaged i...

Страница 7: ...8 1 Trolley Threaded Shaft 1 Lock Washer 3 8 1 Lock Nut 1 4 20 2 Bolt 1 4 20x1 3 4 2 Drywall Anchors 2 Clevis Pin 5 16 x1 1 Lag Screw 5 16 18x1 7 8 2 Screw 6ABx1 1 4 2 Clevis Pin 5 16 x1 1 2 1 Self T...

Страница 8: ...about 4 3 4 12 cm from the far end 1 Remove the straight door arm and hanging bracket packaged inside the front rail and set aside for Installation Step 5 and 12 NOTE To prevent INJURY while unpacking...

Страница 9: ...cm of cable through the window Allow it to hang until Assembly Step 5 Remove the tape from the idler pulley The inside center should be pre greased If dry regrease to ensure proper operation Place the...

Страница 10: ...ley 2 Connect the cable to the retaining slot on the trolley as shown Figure 1 From below push pins of master link bar up through cable link and trolley slot Push master link cap over pins and past pi...

Страница 11: ...N INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH WARNING WARNING WARNING WARNING 1 READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS 2 Install garage door opener ONLY on properly b...

Страница 12: ...r the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 13 for ceiling installation To prevent possib...

Страница 13: ...nting toward the ceiling Mark the vertical set of bracket holes Drill 3 16 pilot holes and fasten the bracket securely to a structural support with the hardware provided Lag Screw 5 16 9x1 5 8 HARDWAR...

Страница 14: ...is in the way you ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket...

Страница 15: ...enient for setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way a...

Страница 16: ...line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to o...

Страница 17: ...white red wire to 1 2 Fasten the Lighted Door Control Button securely with 6ABx1 1 2 screws If installing into drywall drill 5 32 holes and use the anchors provided 3 Run the bell wire up the wall and...

Страница 18: ...ent slipping Thread the other end of the rope through the hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Ensure that the rope and handle...

Страница 19: ...g cord Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be ground...

Страница 20: ...15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the...

Страница 21: ...p hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket again...

Страница 22: ...is required Loosen the sending eye wing nut and readjust aiming directly at the receiving eye Lock in place Loosen the receiving eye wing nut and adjust sensor until it receives the sender s beam When...

Страница 23: ...g holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washers and nuts not provided Figure 2B Metal insulated or light weight fac...

Страница 24: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Страница 25: ...are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that l...

Страница 26: ...5 16 18 Lock Washers 5 16 Ring Fastener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully clos...

Страница 27: ...d in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t close compl...

Страница 28: ...ckwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required t...

Страница 29: ...through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IIMPORTANT SAFETY CHECK Test the Safety Rever...

Страница 30: ...s restored after interruption when the opener is activated Lights will also turn on when someone walks through the open garage door They will turn off automatically after 4 1 2 minutes Bulb size is A1...

Страница 31: ...To prevent possible SERIOUS INJURY or DEATH from a falling garage door If possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanc...

Страница 32: ...r replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Tested to Comply with FCC Standards FOR HOME OR OFFICE USE Operation is subject to the following two conditions 1 this device may not...

Страница 33: ...djustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adjust the UP and DOWN Travel Limits Decrease down travel by tur...

Страница 34: ...t door control touch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white te...

Страница 35: ...wish to operate your garage door 3 Release the button when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard To Add or Reprogram a Hand held...

Страница 36: ...longer open the door It can be used to close the door even after it has expired To set a temporary PIN 1 Press the four buttons for your personal entry PIN not the last temporary PIN then press and ho...

Страница 37: ...m battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope and handle assembly 6 41B4494 1 2 Conductor bell wire white and white red 7 41A5047 1 Door bracket w clevis pin fastener 8...

Страница 38: ...30B532 Capacitor 1 2 HP 30B533 Capacitor 1 3 HP 9 12A373 Capacitor bracket 10 41A3150 Terminal block w screws 11 41D3058 Universal replacement motor bracket assembly Complete with Motor worm bracket...

Страница 39: ...ip 956D 940D 10 Foot 3 m Rail Extension To allow a 10 foot 3 m door to open fully Multi Function Door Control Panel Provides a Lock feature which prevents operation of garage door opener from portable...

Страница 40: ...t by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repa...

Отзывы: