background image

*3-Button Remotes

If provided with your garage door opener, the large
button is factory programmed to operate it. Additional
buttons on any
Security

®

3-Button

remote or compact
remote can be
programmed to operate
other Security

®

garage door openers.

To Erase All Codes From Motor

Unit Memory

To deactivate any unwanted remote,
first erase all codes:

Press and hold the “learn” button on
motor unit until the learn indicator light
goes out (approximately 6 seconds). All
previous codes are now erased. Reprogram each
remote or keyless entry you wish to use.

1. Press and hold the button on the

hand-held remote

*

that you wish

to operate your garage door.

2. While holding the ENTER button,

press and hold the LIGHT button
on the Motion Detecting Door
Control.

3. Continue holding the ENTER and

LIGHT buttons while you press
the push bar on the Motion
Detecting Door Control (all three
buttons are held).

4. Release buttons when the motor

unit lights blink. It has learned the
code. If light bulbs are not
installed, two clicks will be heard.

1. Press and release the “learn”

button on the motor unit. The
learn indicator light will glow
steadily for 30 seconds.

2. Within 30 seconds, press and

hold the button on the hand-held
remote

*

that you wish to operate

your garage door.

3. Release the button when the

motor unit lights blink. It has
learned the code. If light bulbs are
not installed, two clicks will be
heard.

To Add or Reprogram a Hand-held Remote Control

USING THE “LEARN” BUTTON

USING THE MOTION DETECTING DOOR CONTROL

LOCK

LIGHT

LOCK

LIGHT

PROGRAMMING

31

Your garage door opener has already been programmed at the factory to operate with your hand-held remote
control. The door will open and close when you press the large push button.

Below are instructions for programming your opener to operate with additional Security

®

remote controls.

NOTICE:

If this Security

®

garage door opener is operated with a non-rolling code transmitter, the technical

measure in the receiver of the garage door opener, which provides security against code-theft devices, will be
circumvented. The owner of the copyright in the garage door opener does not authorize the purchaser or
supplier of the non-rolling code transmitter to circumvent that technical measure.

Содержание Security+ 2585

Страница 1: ...lease read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properly aligned Periodic checks of the opener are required to ensure safe operation The model number label is located under the light lens on the left side panel of your opener ...

Страница 2: ...c chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change a Keyless Entry PIN 32 Repair Parts 33 34 Rail assembly parts 33 Installation parts 33 Motor unit assembly parts 34 Accessories 35 Repair Parts and Service 36 Warranty 36 TABLE OF CONTENTS When you see these Safety Symbols and Signal Words on the follo...

Страница 3: ...g your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding 1 Lift the door about halfway as shown Release the door If balanced it should stay in place supported entirely by its springs 2 Raise and lower the door to see if there is any binding or sticking If your doo...

Страница 4: ...you proceed with the installation of your opener Access Door Safety Reversing Sensor Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1 4 6 mm ONE PIECE DOOR WITH TRACK Safety Reversing Sensor Support bracket fastening hardware is required See page 12 Header Wall FINISHED CEILING Torsion Spring Extension Spring OR Safety Reversing Sensor Gap between floor and bottom of ...

Страница 5: ... Door Bracket One Piece Rail Styrofoam Belt Pulley Bracket Belt Trolley SECURITY 3 Button Remote Control 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White Black Bell Wire attached Safety Sensor Bracket 2 LOCK LIGHT Motion Detecting Door Control Panel Motor Unit w Light Lenses INSTALLATION HARDWARE Hex Bolt 5 16 18x7 8 4 Hex Screw 8 x 3 8 2 Lag Screw 5 16 9x1...

Страница 6: ... belt and styrofoam REMOVE STYROFOAM Position belt over the motor unit sprocket Motor unit Sprocket Washered Bolt 5 16 18x1 2 Styrofoam Rail Hole Lock Nut 6 ASSEMBLY STEP 2 Set the Belt Tension By hand thread the spring trolley nut on the threaded shaft until it is finger tight against the trolley Figure 1 Do not use any tools Insert a screwdriver tip into one of the nut ring slots and brace it fi...

Страница 7: ...sms 9 Install wall mounted garage door control within sight of the garage door out of reach of children at minimum height of 5 feet 1 5 m away from all moving parts of the door 10 Place entrapment warning label on wall next to garage door control 11 Place manual release safety reverse test label in plain view on inside of garage door 12 Upon completion of installation test safety reversal system D...

Страница 8: ...f the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible SERIOUS INJURY or DEATH Header bracket MUST be RIGIDLY fastened to structural support on header wall or ceiling otherwise garage door might not reverse when required DO NOT install header bracket over drywall Concr...

Страница 9: ...rage Door Header Wall Garage Door UP CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEILING MOUNT ONLY Door Spring Header Bracket 2x4 Structural Support Vertical Centerline of Garage Door Horizontal Line UP CEILING MOUNT ONLY Ceiling Mounting Holes The nail hole is for positioning only...

Страница 10: ...r Bracket Position the opener on the garage floor below the header bracket Use packing material as a protective base NOTE If the door spring is in the way you ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and join with a clevis pin as shown Insert a ring fa...

Страница 11: ...ng an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place a 2x4 laid flat on the top section beneath the rail If the top section or panel hits the trolley when you raise the door pull down on the trolley release arm to disconnect inner and outer sections Slide the ...

Страница 12: ...ng hardware are not provided 1 Measure the distance from each side of the motor unit to the structural support 2 Cut both pieces of the hanging bracket to required lengths 3 Drill 3 16 pilot holes in the structural supports 4 Attach one end of each bracket to a support with 5 16 18x1 7 8 lag screws 5 Fasten the opener to the hanging brackets with 5 16 18x7 8 hex bolts lock washers and nuts 6 Check...

Страница 13: ...t or open circuit 4 Strip 7 16 11 mm of insulation from end of bell wire Connect bell wire to the quick connect terminals as follows white to white and white red to red NOTE When connecting multiple door controls to the opener twist same color wires together Insert wires into quick connect holes white to white and red white to red 5 Use tacks or staples to permanently attach entrapment warning lab...

Страница 14: ...rom the end of the rope to prevent slipping Thread the other end of the rope through the hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Secure with an overhand knot NOTE If it is necessary to cut the rope heat seal the cut end with a match or lighter ...

Страница 15: ...the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Reinstall the cover To avoid installation difficulties do not run the opener at this time RIGHT WRONG To prevent possible SERIOUS INJURY or DEATH from electrocution or fire Be sure power is not connected to the o...

Страница 16: ...or Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such as the wall framing Extension brackets see acc...

Страница 17: ...ip hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket against the wall with curved arms facing the door Be sure there is enough clearance for the sensor beam to be unobstructed If additional depth is needed an extension bracket see accessories or wood blocks...

Страница 18: ...ll glow steadily if wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction If the green indicator light in the receiving eye is off dim or flickering and the invisible light beam path is not obstructed alignment is required Loosen the sending eye wing nut and readjust aiming directly at the receiving eye Lock in place Loo...

Страница 19: ...follows depending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washers and nuts not provided Figure 2B Metal insulated or light weight factory reinforced doors...

Страница 20: ...MINUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Center the door bracket on the top of the door in line with the header bracket as shown Mark either the left and right or the top and bottom holes Metal Doors Drill 3 16 pilot holes and fasten the bracket...

Страница 21: ...ure 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that line up and join with bolts lock washers and nuts Pull the emergency release handle toward the opener at a 45 angle so that the trolley release ar...

Страница 22: ...shers 5 16 Ring Fastener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully closed position Manually close the door and lift the door arm to the trolley The arm should touch the trolley just ahead of the door arm connector hole Refer to the fully closed trolley door arm positions in the illustra...

Страница 23: ...n Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 3 7 5 cm of travel If door still won t close completely and the trolley bumps into the pulley bracket page 4 try lengthening the door arm page 21 and decreasing the down limit If the opener reverses in fully closed position Decrease down travel Turn t...

Страница 24: ... small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required to close the door 2 Test the UP open force Grasp the door bottom when the door is about halfway through UP open travel The door should stop If the door is hard to hold or doesn t stop DECREASE UP open force by tu...

Страница 25: ...run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY CHECK Test the Safety Reverse System after Each adjustment of door arm length limits or force controls Any repair to or adjustment of the garage door including springs and hardware Any repair to or buckling of the ...

Страница 26: ... the Light feature on the Motion Detecting Door Control is activated Bulb size is 100 watts maximum Security light feature Lights will also turn on when someone walks through the open garage door With a Multi Function Door Control this feature may be turned off as follows With the opener lights off press and hold the light button for 10 seconds until the light goes on then off again To restore thi...

Страница 27: ... Outside Keylock and the Keyless Entry accessories To activate press and hold the Lock button for 2 seconds The push bar light will flash as long as the Lock feature is on To turn off press and hold the Lock button again for 2 seconds The push bar light will stop flashing The Lock feature will also turn off whenever the Learn button on the motor unit panel is activated LOCK LIGHT Push Bar Lock But...

Страница 28: ...this device must accept any interference received including interference that may cause undesired operation MAINTENANCE SCHEDULE Once a Month Manually operate door If it is unbalanced or binding call a trained door systems technician Check to be sure door opens and closes fully Adjust limits and or force if necessary See pages 23 and 24 Repeat the safety reverse test Make any necessary adjustments...

Страница 29: ... safety reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adjust the UP and DOWN Travel Limits Decrease down travel by turning down limit adjustment screw clockwise 5 My lights will not turn off when door is open The garage door ope...

Страница 30: ...wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with jumper wire If motor unit activates replace door control wires Symptom Sending indicator light glows steadily receiving indicator light is dim or flashing Realign receiving eye sensor clean lens and secure br...

Страница 31: ...ll be heard 1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote that you wish to operate your garage door 3 Release the button when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard To Add or Reprogram a Han...

Страница 32: ... 1 Press the four buttons for the present PIN then press and hold the button The opener light will blink twice Release the button 2 Press the new 4 digit PIN you have chosen then press Enter The motor unit lights will blink once when the PIN has been learned Test by pressing the new PIN then press Enter The door should move To set a temporary PIN You may authorize access by visitors or service peo...

Страница 33: ...door control panel 2 973LM 3 button remote control 3 10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency Release rope handle assy 6 41B4494 1 2 Conductor bell wire white white red 7 41A5047 1 Door bracket w clevis pin fastener 8 41A4353 1 Header bracket w clevis pin fastener 9 41A5034 Safety sensor kit receiving and sending eyes with 3 9 m 2 conductor bell wire 10 1...

Страница 34: ...0 Capacitor 56uF 8B 30B529 Capacitor 40uF 8C 41A5637 Resistor 9 41A3150 Terminal block w screws 10 41D5563 1 Universal replacement motor bracket assembly Complete with Motor worm bracket gear case bearing assembly RPM sensor KEY PART NO NO DESCRIPTION 11 41A5633 Cover 12 41A2818 Limit switch drive retainer 13 41D3452 Limit switch assembly 14 41A5532 Gear case 15 41A2822 1 Interrupter cup assembly ...

Страница 35: ...ssword for visitors or service persons This temporary password can be limited to a programmable number of hours or entries 3 Button Mini Remote Control with Security With key ring and fastening strip 902LM 903LM 2 3 Door Multi Function Wall Control Ideal for homes with up to three garage doors Combine up to three controls into one wall control panel for a neat compact appearance Enhanced functions...

Страница 36: ...r warranty repair You will be advised of shipping instructions when you call Please include a brief description of the problem and a dated proof of purchase receipt with any product returned for warranty repair Products returned to Seller for warranty repair which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole...