Chamberlain Secure Home SH-9191AU Скачать руководство пользователя страница 6

6

201102-01

Note:

 When first turned on wait about 1 

1

/

2

 minutes 

for the circuitry to calibrate.

* resets to Auto Mode at dawn.

OPERATION

MANUAL MODE

... back on.

1 Second 

OFF 

then

...

Manual  mode  only  works  at 

night  because  daylight  returns 

the sensor to AUTO.
Flip the light switch off for one 

second then back on to toggle 

between AUTO and MANUAL 

MODE.
Manual mode works only with 

the ON-TIME switch in the 1, 

5, or 10 position.

SPECIFICATIONS

Range .................................................Up to 9.1 m (30 ft.) [varies with surrounding temperature]

Sensing Angle.....................................Up to 180°

Electrical Load ...................................See label on fixture for maximum wattage rating

Bulb Type ...........................................E27 Screw Base, Type “A”

Sensor Capacity ..................................Up to 360 Watts (1.5A) maximum tungsten incandescent

Power Requirements ...........................230 VAC, 50 Hz

Operating Modes ...............................TEST, AUTO, and MANUAL MODE

ON-Timer ..........................................1, 5, 10 minutes

Test Timer ..........................................5 Seconds

Manual Mode Timer ..........................Dusk-to-Dawn

Ingress Protection ...............................IP23

MANUAL MODE

AUTO

TEST

ON-TIME Switch at 1, 5, 

or 10 minutes

MODE SWITCHING SUMMARY

Flip light switch 

off for one second 

then back on*

* If you get confused while switching modes, turn 

the power off for one minute, then back on. After 

the calibration time the control will be in the AUTO 

mode.

The Chamberlain Group reserves the right to discontinue products and to change specifications at 

any time without incurring any obligation to incorporate new features in products previously sold.

Mode:

On-Time

Works: Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10

Minutes

x

Manual

To Dawn*

x

Содержание Secure Home SH-9191AU

Страница 1: ...The light control requires 230 volts AC If you want to use Manual Mode the control must be wired through a switch It is illegal for persons other than a licensed electricianorpersonauthorizedbylegislation to work on fixed wiring or other electrical installations Before installation record the model num ber listed inside the fixture Attach receipt in case of possible warranty issues Model Number 20...

Страница 2: ... mounted 1 8 meters 6 feet above the ground Do not use dimmer switches or timers with this fixture The sensor on this light fixture detects motion by the movement of heat across the coverage area However following are examples of objects that also produce heat and can cause the sensor to trigger Pools of Water Air Conditioners Dryer Vents Animals Heating Vents Automobile Traffic If you suspect tha...

Страница 3: ...unting screws are paralleltotheground beforetighteningbracket to wall see Figure 2 5 Useapowerdrilltodrillintothewalltoprovide a suitable mounting for the screws Bracket mounting screws are not included Use 4mm dia 8G x 30mm wood screws Care should be taken to avoid drilling or screwing into concealed electrical wiring For solid brick walls screws and masonry plugs should be used 6 Attachmountingb...

Страница 4: ...cable install fixture top using two decorative screws see Figure 5 WIRING WARNING Turn power off at circuit breaker or fuse Place tape over circuit breaker switch and verify power is off at the fixture Terminal Block From Fixture From AC Source Green Yellow Green Yellow Blue Blue or Black Brown Red or Brown Figure 3 Wall Mounting Bracket Mounting Screw Decorative Nut Figure 4 Connect the fixture w...

Страница 5: ...or 5 seconds after motion has stopped and then turn off 4 Increase or decrease the sensitivity as needed Toomuchsensitivitymaycausefalsetriggering due to heat sources in the coverage area see Troubleshooting section 5 Set the amount of ON TIME you want the light to stay on after motion is detected 1 5 or 10 minutes The timer will reset as long as there is motion present Once motion has stopped the...

Страница 6: ...ensor Capacity Up to 360 Watts 1 5A maximum tungsten incandescent Power Requirements 230 VAC 50 Hz Operating Modes TEST AUTO and MANUAL MODE ON Timer 1 5 10 minutes Test Timer 5 Seconds Manual Mode Timer Dusk to Dawn Ingress Protection IP23 MANUAL MODE AUTO TEST ON TIME Switch at 1 5 or 10 minutes MODE SWITCHING SUMMARY Flip light switch off for one second then back on If you get confused while sw...

Страница 7: ...ating normally under these conditions 2 Set ON TIME switch to 1 5 or 10 minutes Light comes on for no apparent reason 1 Lightcontrolmaybesensingsmallanimalsorautomobile traffic 2 Sensitivity is set too high 1 Reduce sensitivity 2 Reduce sensitivity Light stays on continuously 1 The sensor may be picking up a heat source like an air vent dryer vent or brightly painted heat reflective surface 2 Ligh...

Страница 8: ... or return the Unit to you Exclusions This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding installation operation maintenance and testing of the Unit or of any product with which the Unit is used 2 any attempt by a person other than an authorised installer to repair dismantle reinstall or move the Unit to anot...

Отзывы: