background image

CONTENTS

PAGE

SAFETY INSTRUCTIONS . . . . . . . . . . .1
BEFORE YOU BEGIN . . . . . . . . . . . . . .2
DOOR TYPES . . . . . . . . . . . . . . . . . . . .2
CARTON INVENTORY . . . . . . . . . . . . .3
RAIL SIZES . . . . . . . . . . . . . . . . . . . . . .3
TOOLS REQUIRED . . . . . . . . . . . . . . . .4
HARDWARE PROVIDED . . . . . . . . . . . .4
COMPLETED INSTALLATION . . . . . . . .4
CONTROL PANEL . . . . . . . . . . . . . . . . .5
ASSEMBLY . . . . . . . . . . . . . . . . . . . . . .6
INSTALLATION . . . . . . . . . . . . . . . . .7-10
OPERATE THE MANUAL RELEASE . .10
ADJUSTMENT . . . . . . . . . . . . . . . .11-12
INSTALL THE PROTECTOR
SYSTEM (OPTIONAL) . . . . . . . . . . . . .13

PROGRAM TRANSMITTER TO
OPERATE OPENER LIGHT . . . . . . . .13
TIMER TO CLOSE . . . . . . . . . . . . . . . .14
INSTALL WARNING LABELS . . . . . . .15
PARTIAL OPENING FEATURE . . . . . .15
WIRELESS PROGRAMMING . . . . . . .16
USING YOUR OPENER . . . . . . . . . . .17
CARE OF YOUR OPENER . . . . . . . . .17
REPLACE BATTERIES IN
TRANSMITTER . . . . . . . . . . . . . . . . . .17
ACCESSORIES . . . . . . . . . . . . . . . . . .18
TROUBLESHOOTING . . . . . . . . . . . . 19
DIAGNOSTICS . . . . . . . . . . . . . . . . . . 20
SPECIFICATIONS . . . . . . . . . . . . . . . .21
WARRANTY . . . . . . . . . . . . . . . . . .22-23

Warning: If your garage has no service entrance door, a E1702M outside
quick release must be installed. This accessory allows manual operation
of the garage door from outside in case of power failure.

The Protector System

TM

(IR Beams) must be used for all

installations where the closing force as measured on the
bottom of the door is over 400 N (40 kgf). 
Excessive force will
interfere with the proper operation of the Safety Reverse System
or damage the garage door.

S

PECIAL NOTE: Chamberlain strongly recommends that

The Protector System

TM

(IR Beams) be installed on all garage

door openers.

Installers must ensure that the doors are installed in a
compliant manner as per AS/NZS 60335-2-95.

After installation, ensure that the parts of the door do not
extend over public footpaths or roads.

Install the wireless wall control (or any additional wall control) in
a location where the garage door is visible, at a height of at
least 1.5 m and out of the reach of children. Do not allow
children to operate push button(s) or transmitter(s). 
Serious
personal injury from a closing garage door may result from
misuse of the opener.

Permanently fasten the Warning Labels in Prominent Places,
adjacent to Wall Controls and on manual release mechanism as
a reminder of safe operating procedures.

Activate opener only when the door is in full view, free of
obstructions and the opener is properly adjusted. No one
should enter or leave the garage while the door is in motion.

Automatic Door- The door may operate unexpectedly, therefore
do not allow anything to stay in the path of the door.

Do not allow children to play near the door, or with door
controls. Keep transmitters away from children.

Disconnect electric power to the garage door opener before
making repairs or removing covers.

If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid hazard.

This opener should not be installed in a damp or wet space
exposed to weather.

To avoid damage to very light doors (such as fibreglass,
aluminium or steel doors), an appropriate reinforcement should
be added. To do so, contact the door manufacturer.

• Failure to comply with the following instructions may result in serious personal injury or property damage.

• Read and follow all instructions carefully.
• The garage door opener is designed and tested to offer safe service, provided it is installed and operated in

strict accordance with the instructions in this manual.

These safety alert symbols mean WARNING : A possible risk to personal safety or property
damage exists.

Keep garage door balancedDo not let the garage door
opener compensate for a binding or sticking garage door.
Sticking, binding or unbalanced doors must be repaired
before installing this opener.

Do not wear rings, watches or loose clothing while
installing or servicing a garage door opener. Wear gloves,
safety goggles and suitable protective clothing where
appropriate.

Frequently examine the door installation, in particular
cable, springs and mountings for signs of wear, damage or
imbalance. Do not use if repair or adjustment is needed
since springs and hardware are under extreme tension
and a fault can cause serious personal injury.

To avoid serious personal injury from entanglement,
remove all ropes, chains and locks connected to the
garage door 
before installing the door opener.

Installation and wiring must be in compliance with your
local building and electrical codes.

The safety reverse system test is very important. Your
garage door MUST reverse on contact with a 40 mm
obstacle placed on the floor. Failure to properly adjust the
opener may result in serious personal injury from a closing
garage door. Repeat the test once a month and make
any necessary adjustments.

This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety.

Use the Manual Release only for the seperation of the
carriage from the drive and - if possible - ONLY with the
door closed. Do not use the red handle to push the door
up or pull it down. Operation of the emergency release can
lead to uncontrolled movements of the door, if springs are
weak or broken or if the door is unbalanced. Mount the
release handle of the emergency release at a height less
than 1.8 m from the floor.

START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS

WARNING!

1

SAVE THESE INSTRUCTIONS

Содержание SectionalLift Plus CS105MYQ

Страница 1: ...re reference CS105MYQ Sectional Garage Door Opener Installation and Operating Instructions This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY chamberlaindiy com au chamberlaindiy co nz ...

Страница 2: ...ified persons in order to avoid hazard This opener should not be installed in a damp or wet space exposed to weather To avoid damage to very light doors such as fibreglass aluminium or steel doors an appropriate reinforcement should be added To do so contact the door manufacturer Failure to comply with the following instructions may result in serious personal injury or property damage Read and fol...

Страница 3: ...ace supported entirely by its springs Raise and lower the door to see if there is any binding or sticking 20 kgf is the absolute maximum allowable force to raise or lower the door in any position If your door binds sticks or is out of balance call a trained door technician Electrical Connection A 240 V General Purpose Outlet GPO ie Power Point must be available in close proximity to the powerhead ...

Страница 4: ...Y 2 1 Opener 2 Hand held transmitter 3 Remote control visor mount 4 Curved door arm 5 Hanging bracket 2 6 Rail bracket 7 Header bracket 8 Door bracket 9 Hardware bag 10 Rail assembly 11 C Rail bracket 2 12 Centre Rail Bracket 13 Manual 14 Warning labels 15 Warranty card Your garage door opener and rail are packed in a single carton The SectionalLift CS65MYQ opener cartons contain the opener the ra...

Страница 5: ...oor bracket 14 C Rail brackets 15 Centre rail bracket As you proceed with the assembly installation and adjustment procedures in this manual you may find it helpful to refer back to this illustration of a completed installation COMPLETED INSTALLATION 6 1 Clevis pin 80 mm Section 13 2 R clip Section 13 3 Hexagonal head screw Sections 15 17 4 Nut M8 Sections 15 17 5 Flat washer M8 Sections 15 17 6 C...

Страница 6: ...linked If the link is removed the opener will not operate Remove the link and install a Safety switch to prevent the opener from activating the garage door when the built in pedestrian door is open Terminals are designed for operationg with a dry contact automatic sensing switch such as model SW02 or similar Door safe condition closed contacts Door unsafe condition open contacts No Function Colour...

Страница 7: ...ws item 9 in Hardware Provided Section 5 This completes the assembly of the door opener to the rail FASTEN RAIL TO OPENER 9 10 The segmented rail is largely preassembled and consists of 4 parts The carriage push rod release handle the guide pulley and the lintel bracket with belt tensioner are in the front part A The seating for the drive shaft and the sprocket are in the rear part B Hardware item...

Страница 8: ...nting toward the ceiling Drill and secure the Header Bracket using the most suitable variation of holes 5 If using the wood screws provided 3 item 8 in the Hardware Provided Section 5 uses a 4 5 mm pilot drill If securing to a metal fixture self tapping tek screws may be more suitable B Ceiling mount extend vertical centre line 2 onto the ceiling Centre the header bracket 1 on the vertical mark no...

Страница 9: ...wn 3 The final positioning of the rail should be relatively parallel to the horizontal door panels 14 Disengage the trolley mechanism see section Operating the manual release and slide it back towards the powerhead Secure the hanging push arm up into the rail assembly temporarily using tape or rope to avoid a hazard Rail Door 50 mm spacer should be used to determine the correct mounting position H...

Страница 10: ...d Section 5 Item 10 in Hardware Provided Section 5 fig 3 Item 8 in Hardware Provided Section 5 Item 10 in Hardware Provided Section 5 Item 3 in Hardware Provided Section 5 Item 4 in Hardware Provided Section 5 HANG THE OPENER 15 The opener must be securely fastened to a sound structural support above the opener 1 Postion the opener as in the previous step Check the rail is centred over the door En...

Страница 11: ...if required see figure 3 Unscrew the front two screws in the trolley assembly Remove the straight arm pivot and reassemble with the curved arm bracket ATTACH DOOR ARM TO TROLLEY OPERATING THE MANUAL RELEASE The manual release mechanism enables the door to be manually operated during power outages or in an emergency The RED Manual Release cord is preassembled to the trolley When the opener is insta...

Страница 12: ... the door is in the desired UP position press and release the PROG Button The DOWN Arrow Button will begin to flash figure 4 4 Press and hold the DOWN Arrow Button until the door is in the desired DOWN position figure 5 NOTE The UP and DOWN Arrow Buttons can be used to move the door up and down as needed 5 Once the door is in the desired DOWN position press and release the PROG Button The UP Arrow...

Страница 13: ...d speed Repeat the process above toggle between the two settings PROGRAM THE TRAVEL SPEED OPTIONAL 21 TEST THE SAFETY REVERSE SYSTEM Procedure With door opened place a 40 mm obstacle 1 laid flat on the floor under the garage door Operate the door in the down direction The door must reverse off the obstacle If the door stops on the obstacle remove obstacle and repeat Program the Limits and Force St...

Страница 14: ...ion THE PROTECTOR SYSTEMTM IR BEAMS OPTIONAL To prevent entrapment install The Protector System IR Beams no higher than 100 mm above the floor Disconnect power to the garage door opener before installing The Protector System IR Beams 22 23 PROGRAM TRANSMITTERS TO THE OPENER LIGHT To Program your transmitters to operate your garage door opener light follow the below steps 1 Press and release the LE...

Страница 15: ...ht flashes twice 3 Press the UP button once for each 10 second increment required of TTC figure 3 eg twice for 20 seconds Press the DOWN arrow to reduce if needed 4 Press and release the PROG button to save this time figure 4 courtesy light will flash once TTC is now activated TEST Operate the door to the UP position Keep clear of the IR Beams and check the door closes after the preset time To Dea...

Страница 16: ...her for 3 seconds figure 3 The courtesy light will flash twice indicating the deactivation has occurred NOTE Erasing all transmitter codes as in the Wireless programming section will also delete this feature PARTIAL OPENING FEATURE PET Indicator LED Indicator LED Door Fully Closed figure 1 figure 3 26 Indicator LED figure 2 1 service www m m B B A 2 114A3361 For Service Call Installation Date 3 13...

Страница 17: ...utton on the garage door opener 2 Press and release the yellow LEARN button The LED indicator light will glow steadily 3 Enter a 4 digit personal identification number PIN of your choice on the keypad 4 Press and hold the ENTER button Check to see if the opener light flashes Release the ENTER button after the light flashes To change an existing keyless entry PIN 1 Enter the existing programmed PIN...

Страница 18: ...nce a Month Manually operate door If it is unbalanced or binding call a qualified door technician Check to be sure door opens closes fully Adjust limits and or force if necessary Repeat the safety reverse test Make any necessary adjustments Once a Year Lightly grease the belt and inside the rail assembly where the trolley slides Internally the opener does not require additional lubrication Lightly...

Страница 19: ...7 M BBU24V 1 Model E950C 2 Channel remote control 2 Model E940C 1 Channel visor remote control 3 Model 774AML The Protector SystemTM 4 Model E1702C Quick release lock 5 Model E840C E840M Wireless Keypad 6 Model 827AU myQ Remote LED Light 7 Model M BBU24V Battery Back up 31 ...

Страница 20: ...ally on excessively heavy doors check the Motor Shaft Adapter has not stripped 12 The Up and DOWN arrows on the control panel are flashing in sequence Check the diagnostic code on next page 1 Opener doesn t operate from either door control or transmitter Does the opener have electric power Plug lamp into outlet If it doesn t light check the fuse box or the circuit breaker Some outlets are controll...

Страница 21: ...or correct as needed The Protector System IR Beams are misaligned or were momentarily obstructed Realign both sensors to ensure both LEDs are steady and not flickering Make sure nothing is hanging or mounted on the door that would interrupt the sensors path while closing No RPM pulses have been detected Check the door manually for balance binding or obstructions Internally the possible cause may b...

Страница 22: ...Adjustable door arm Pull cord trolley release Safety Personal Push button stop in UP and DOWN direction Automatic safety reverse in both UP and DOWN direction Electronic Automatic force adjustment Electrical Transformer overload protector and low voltage push button wiring Limit Device Mechanical Passpoint RPM sensor Limit Adjustment Electronic Soft start Soft stop Dimensions Length Overall 3 24 m...

Страница 23: ...roup Inc Warranty Registration Register your warranty at chamberlaindiy com au warranty or chamberlaindiy co nz warranty DONʼ T FORGET Get Connected with Visit www chamberlaindiy com au or www chamberlaindiy co nz for more details Additional purchase of the myQ Connectivity Kit is required to enable myQ functionality ...

Страница 24: ... a fee to repair replace and or return the Unit to you This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding specifications installation operation maintenance and testing of the Unit or of any product with which the Unit is used 2 any attempt by a person other than a Professional Dealer to repair dismantle rein...

Отзывы: