2

LOGIC 2

To Program open Mid-Stop:
1. Close the door.
2. Set dip switches to "Set Mid-Stop".
3. Press open (the door will begin moving).
4. Press stop when the desired Mid-Stop height is reached.
5.  Return the dip switches to the desired wiring type (C2, B2, 

etc.). The door will now stop at this height every time the door 

is opened.

WARNING DEVICES MODULE

LOAD

R7

D3

D4

1

+5V  +24V

OUT

+24VDC

D2

Q2

K2

R4

3
2

1

R2

Q1  

D1

R6

Q3

C1

R8

C2

K1

J1

10

8

4

3

1

TB1

R8

R9

R1

R3

R5

13

+

TB2

RED

LT

.

GREEN

 LT

.

120V IN

L1        L2

Figure 1

Light

Light box conduit w/wires

Power LEDs

24 Vdc for Horn/Strobe

115 Vac power only

SET  

MID-STOP

ON

OFF

STEP 5: (FIGURE1)

Complete wiring connections as follows:
•   Connect red wire to red light terminal on the Red/Green Light 

Control Module connector.

•   Connect black wire to green light terminal on the Red/Green 

Light Control Module connector.

•   Connect white wire to L1 (NEUTRAL) on the power terminal 

strip.

•   Connect black jumper from L2 (HOT) on the power terminal 

strip to (120V IN) terminal on the Red/Green Light Control 

Module connector.

STEP 6:

Install red and green light bulbs (not provided). Maximum 

wattage should not exceed 75 watts.

OPTIONAL MID-STOP PROGRAMMING:

LOGIC 3

To Program open or down (close) Mid-Stop:
1.  Open the door to set close Mid-Stop or close door to set open 

Mid-Stop.

2. Turn selector dial to “PROGRAM.”
3. Press the “MID SET” button on logic board.
4.  Press the OPEN button for open Mid-Stop, wait until the door 

reaches the desired Mid-Stop height, then press the STOP 

button.

OR
   Press the CLOSE button for down Mid-Stop, wait until the 

door reaches the desired Mid-Stop height, then press the 

STOP button.

5. Press the MID SET button to complete programming.
6. Turn selector dial back to desired wiring type.

1

2

3

4

1

2

3

4

Green 

Light

Red 

Light

Red

Red

White

White

Black

Black