background image

21

INSTALLATION STEP 7

Install the Door Control
and Connect all Wiring

Locate door control within sight of door, at a minimum
height of 5 feet where small children cannot reach, away
from moving parts of door and door hardware. If installing
into drywall (Figure 1), drill 5/32" holes and use anchors
provided. For pre-wired installations (as in new home
construction), it may be mounted to a single gang box
(Figure 2).

NOTE:

After installation, a green indicator light

behind the cover will indicate proper connection. If not lit,
the Lock and Light features will not function (reverse wires
to correct).

1. Strip 1/4" of insulation from one end of bell wire and

connect to the two screw terminals on back of door
control by color: white to 2 and white/red to 1 
(Figure. 3).

2. Remove white cover by gently pushing both thumbs

against upper corners of cover on back side of door
control. Fasten with 6ABx1-1/4"self-tapping screws
(standard installation) or 6-32x1" machine screws (into
gang box) as follows:

• Install bottom screw, allowing 1/8" to protrude above

wall surface.

• Position bottom of door control on screw head and

slide down to secure. Adjust screw for snug fit.

• Drill and install top screw with care to avoid

cracking plastic housing.

Do not overtighten.

• Insert bottom tabs and snap on cover.

3.

(Standard installation only)

Run bell wire up wall and

across ceiling to motor unit. Use insulated staples to
secure wire in several places. Do not pierce wire with a
staple, creating a short or open circuit. If your access
door is near the garage door, you may run this wire with
the Safety Reversing Sensor wires along the top of the
rail. See page 18.

4. Insert all wires through the opening on top of motor unit

above the terminal block on the back panel (Figure 4).

5. Cut excess and 

strip 7/16"

of insulation from each end.

Insert door control wire into quick-connect terminals by
color: white wire to white, white/red wire to red.

Separate white and white/black wires sufficiently to
connect to the opener quick-connect terminals. Twist like
colored wires together. Insert wires into quick-connect
holes: white to white and white/black to black (Figure 4).

NOTE:

When connecting multiple door controls to the

opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.

6. Use tacks or staples to permanently attach entrapment

warning label to wall near door control, and manual
release/safety reverse test label in a prominent location
on inside of garage door.

DO NOT connect power and operate opener at this
time. See Step 9 on page 22.

Dry Wall Anchors

Insulated
 Staples 

6AB x 1-1/4" Screw
(standard installation)

6-32 x 1" Screw
(pre-wired installation)

HARDWARE SHOWN ACTUAL SIZE

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires. 
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of

reach of children at a minimum height of 5 feet, and away
from all moving parts of door.

• NEVER permit children to operate or play with door control

push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is properly

adjusted, and there are no obstructions to door travel.

• ALWAYS keep garage door in sight until completely closed.

NEVER permit anyone to cross path of closing garage door.

WARNING

CAUTION

WARNING

WARNING

To release wire, push in tab
 with screwdriver tip

Door Control
Connections

7/16"

Strip wire 7/16"

Red

Black

White

Figure 2

To Replace
Insert Bottom Tabs First

PRE-WIRED 
INSTALLATION

24 Volt
Bell Wire

LOCK

LIGHT

LOCK

LIGHT

To Replace
Insert Bottom Tabs First

Figure 1

STANDARD 
INSTALLATION

Single
Gang Box

Figure 3

Figure 4

To 

Door

Control

To
Sensors

Quick-
Connect
Terminal

MULTI-FUNCTION
WALL CONTROL

LIGHTED 
DOOR 
CONTROL

Terminal
Screws

Содержание POWER DRIVE PD420

Страница 1: ...and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properly aligned Periodic ch...

Страница 2: ...ol 32 To open the door manually 32 Care of your garage door opener 33 Having a problem 34 Programming Pages 35 36 To add a hand held remote control 35 To erase all codes 35 Multi function remotes 35 T...

Страница 3: ...ts or their hardware all of which are under EXTREME tension Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement Pre...

Страница 4: ...bracket and additional fastening hardware may be required Installation Step 4 Depending upon garage construction extension brackets or wood blocks may be needed to install sensors Installation Step 4...

Страница 5: ...sing Sensor FINISHED CEILING Support bracket fastening hardware is required See page 20 Safety Reversing Sensor Header Wall Access Door Gap between floor and bottom of door must not exceed 1 4 Motor u...

Страница 6: ...ensors 1 Sending Eye and 1 Receiving Eye with attached 2 Conductor White White Black Bell Wire Safety Reversing Sensor Mounting Bracket 2 SECURITY Single Function Remote Control Transmitter Model 460...

Страница 7: ...rocket Coupling Sleeve Bolt 1 4 20x1 3 4 8 NOTICE Handle Nut 5 16 18 4 Ring Fastener 3 Clevis Pin 5 16 x2 3 4 1 Insulated Staples 30 Dry Wall Anchors 2 Clevis Pin 5 16 x1 1 Rope Self Threading Screw 1...

Страница 8: ...f debris while you are working Center Rail Trolley Rack Extend End Rails Outward Extend End Rails Outward Rail Assembly Carton Remove Cardboard Packing Remove Cardboard Packing Rail Support Braces Str...

Страница 9: ...osition another brace on the opposite side of the rail over the bolts add 1 4 20 lock nuts and hand tighten Insert two additional bolts and hand tighten 7 Keeping the rail straight and on a level surf...

Страница 10: ...rew holes in the rail with those in the motor unit bracket Insert two 1 4 20x5 8 hex screws and lock nuts Tighten securely with a 7 16 socket wrench Slide the trolley onto and along the bottom of the...

Страница 11: ...ems technician before installing opener 4 Disable all locks and remove all ropes connected to garage door before installing opener to avoid entanglement 5 Install garage door opener 7 feet or more abo...

Страница 12: ...of travel as shown Draw an intersecting horizontal line on the header wall 3 above the high point This height will provide travel clearance for the top edge of the door Proceed to Step 2 page 14 One p...

Страница 13: ...shown Measure the distance from the top of the door to the floor Subtract the actual height of the door Add 8 to the remainder See Example 3 Close the door and draw an intersecting horizontal line on...

Страница 14: ...arage Door Travel Vertical Center Line Header Wall Garage Door UP CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to m...

Страница 15: ...n a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and join with a clevis pin as shown Insert a ring fastener to s...

Страница 16: ...Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of sectional gar...

Страница 17: ...flush with the lip hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Place the bracke...

Страница 18: ...the garage door you may choose to install the door control at this time and run the door control wire along the rail with the sensor wires Use one rail channel for the door control wire and the other...

Страница 19: ...r setting an ideal door to rail distance Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place a 2x4 laid flat on the...

Страница 20: ...If you wish to utilize the two center mounting tabs you must triangulate the vertical brackets for additional stability See Figure 3 6 Check to make sure the rail is centered over the door or in line...

Страница 21: ...rminals by color white wire to white white red wire to red Separate white and white black wires sufficiently to connect to the opener quick connect terminals Twist like colored wires together Insert w...

Страница 22: ...at the receiving eye Lock in place Loosen the receiving eye wing nut and adjust the sensor vertically and or horizontally until it receives the sender s beam When the green indicator light glows stea...

Страница 23: ...the rope to prevent slipping Thread the other end of the rope through the hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet above the floor Secure with an overha...

Страница 24: ...etween the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washe...

Страница 25: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Страница 26: ...3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 from the solid end Reconnect to trolley with cut end down as shown Bring arm se...

Страница 27: ...als 2 of trolley travel Closed door adjustment decrease DOWN travel limit Turn the DOWN limit adjustment screw clockwise 5 complete turns 27 Nuts 5 16 18 Lock Washers 5 16 Ring Fastener Straight Arm S...

Страница 28: ...ot close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 of travel If door still won t close completely try lengthening the door arm page 26 and...

Страница 29: ...mpletes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required to close the door 2 Test the UP open force Grasp...

Страница 30: ...he one inch board remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment IMPORTANT SAFETY CHECK Repeat Adjustment Steps 1 2 and 3 after Each adjustment of d...

Страница 31: ...System If you purchase a new remote or if you wish to deactivate any remote follow the instructions in the Programming section Activate your opener with any of the following The hand held Remote Contr...

Страница 32: ...1 2 minutes Press again to turn it off sooner The 4 1 2 minute interval can be changed to 1 1 2 2 1 2 or 3 1 2 minutes as follows Press and hold the Lock button until the light blinks about 10 seconds...

Страница 33: ...rication Do not grease the door tracks FORCE CONTROLS LIMIT CONTROLS 1 3 9 7 5 kg kg THE REMOTE CONTROL BATTERY The lithium battery should produce power for up to 5 years To replace battery use the vi...

Страница 34: ...travel See Adjustment Step 1 Repeat the safety reverse test after the adjustment is complete 8 The door stops but doesn t close completely Review the travel limits adjustment procedures on page 28 Rep...

Страница 35: ...Multi Function Door Control all three buttons are held 4 Release buttons when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard 1 Press and...

Страница 36: ...der 1 Press the four buttons for the present PIN then press and hold the button The opener light will blink twice Release the button 2 Press the new 4 digit PIN you have chosen then press Enter The mo...

Страница 37: ...1A5273 14 Multi function door control 2 29B137 Visor clip 3 41A5056 17 1 function remote control case no circuit board 4 41A5056 18 3 function remote control case no circuit board 5 10A20 3V 2032 Lith...

Страница 38: ...ket light socket limit switch 8 41A5388 Motor drive assy complete with 8a 144B41 22T Pulley 8b 144B42 28T Pulley 8c 20B17 Drive belt 8d 158A69 Retainer rings 8e 41C556 Isolator bracket spacers KEY PAR...

Страница 39: ...ich prevents operation of garage door opener from hand held remotes and a Light Feature for constant light Motion Detecting Control Panel Multi function door control with motion sensor that automatica...

Страница 40: ...nstructions when you call the toll free service number Please include a brief description of the problem and a dated proof of purchase receipt with any product that is returned for warranty repair Pro...

Отзывы: