background image

19

+

+

PUSH 

BUTTON

DOOR SENSOR

(SUPERVISED)

DOOR STRIKE

MAGLOCK

DOOR SENSOR

(NON-SUPERVISED)

OR

EOL (End of Line) Resistor 

(1k ohm)

PROXIMITY 

SENSOR

For DC Power:

Install a 1N4005 

diode or equivalent

Use 18-22 AWG

Power for Maglock

(Not Provided)

DO NOT

 use the power 

supply for the controller 

Use 18-22 AWG

For DC Power:

Install a 1N4005 

diode or equivalent

Power for Door Strike

(Not Provided)

REQUEST TO EXIT

GROUND

SUPERVISED

NORMALLY OPEN

COMMON

NORMALLY CLOSED

NORMALLY OPEN

COMMON

NORMALLY OPEN

COMMON

NORMALLY CLOSED

COMMON

OR

OR

REQUEST TO EXIT

SUPERVISED (DOOR STATUS)

*PRIMARY RELAY

ALARM BYPASS

NORMALLY OPEN

COMMON

AUXILIARY RELAY

OR

NOTE: 

The length of the unshielded 

wires should be kept to a minimum to 

avoid electrical noise.

RED LED - brown

GREEN LED - orange

DATA 1 - white

DATA 0 - green

GROUND - black

12Vdc - red

READER

OR

KEYPAD

WIEGAND

LIGHT

LOAD
LINE

NEUTRAL

Isolation

Relay

Low 

Voltage 

Power 

Supply

NOTE:

 For KPR2000 

keypad, wire the pink and 

black (ground) wires together.

For AC Power:

Install a Siemens S10K30MOV 

(Metal Oxide Varistor) (provided) 

or equivalent

For AC Power:

Install a Siemens

S10K30MOV

(Metal Oxide Varistor) 

(provided) or equivalent

DOOR 1 or 2

* NOTE:

 MAGLOCK, door strike 

and ALARM BYPASS not 

evaluated by UL.

NOTE:

 

DO NOT 

run high voltage 

power within 

the CAPXM 

enclosure.

Door Access

Disconnect power BEFORE making electrical connections. 

Below is an example of a wiring setup for door access. Door access can be 

wired to Door 1 or 2 on the Door Board.

PRE-INSTALL

NETWORK

INSTALL

ACCESS CONTROL

INTRODUCTION

INTRODUCTION

PRE-INSTALL

NETWORK

INSTALL

ACCESS CONTROL

INTRODUCTION

PRE-INSTALL

NETWORK

INSTALL

ACCESS CONTROL

INTRODUCTION

PRE-INSTALL

NETWORK

INSTALL

ACCESS CONTROL

INTRODUCTION

PRE-INSTALL

NETWORK

INSTALL

ACCESS CONTROL

Содержание myQ Business CAPXM

Страница 1: ...1 myQ Business Smart Video Intercom M INSTALLATION MANUAL Model CAPXM...

Страница 2: ...ress push buttons may not be legal Single action exits may be required ALWAYS obtain proper permits and approvals in writing BEFORE installing equipment DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MO...

Страница 3: ...7 Tools Needed 7 Dimensions 8 System Specifications 8 Wire Specifications 9 Internet Requirements 10 PRE INSTALL 1 Setup a myQ Business Account 11 INSTALL 2 Remove Knockouts 12 Mount the CAPXM 13 Ins...

Страница 4: ...NTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL CAPXM Overview Smart Video Intercom M Model CAPXM is a cloud based access control solution that includes an integrated video camera enabling adva...

Страница 5: ...N PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL Control Board Overview Power Expansion Wi F...

Страница 6: ...1 Gated Operator Door Strikes Maglocks Lights for control only power to be provided by external power supply Alarm Shunt Relay Output 2 Wiegand Output 1 Standard 26 bit 30 bit Wiegand HID 37 bit with...

Страница 7: ...ACCESS CONTROL INTRODUCTION INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTR...

Страница 8: ...n Air Line of Sight to front of panel range will vary depending on obstructions Built in LiftMaster Passport Receiver Security 2 0 Wireless Communication to Gate Operator Up to 750 feet 228 6 m Open A...

Страница 9: ...nduits must be UL approved for low and high voltage Refer to the NEC for additional wiring requirements Category 5e cabling is the minimum performance category recommended Wiring shall be in accordanc...

Страница 10: ...DERATIONS DO NOT use Wi Fi extender devices These may introduce latency in the connection leading to choppy or loss of reliable video transmission If using a Wi Fi signal strength tool or app a contin...

Страница 11: ...ng the information required on the Installation Readiness Survey 2 You will get a welcome email from LiftMaster Accept the invitation and register or login to your account 3 Setup the facility select...

Страница 12: ...by laying down a cloth or other protective material 2 Lay the CAPXM face down on the protective material 3 Identify which knockouts need to be removed based on your application 4 Use a center punch t...

Страница 13: ...ter the installation is complete Allow 1 8 in 3 175 mm of space between the bottom of CAPXM and the wall if flush mounting CAPXM without the trim kit ADA Compliance When mounting the CAPXM at a pedest...

Страница 14: ...Run the wire from the CAPXM to suitable earth ground NOTE Shield connections on boards should not be connected to main earth ground connection Ground wire 12 AWG minimum Earth ground rod Other ground...

Страница 15: ...output wires on the power supply Black is negative and red is positive 2 Remove the PWR INPUT terminal block from the Control Board 3 Connect the power supply wires to the PWR INPUT terminal block red...

Страница 16: ...l board will light flicker the control board is located on the back of the CAPXM display If the green LED is not lit check the connections on the CAPXM and the Ethernet hub 2 On the display select Wir...

Страница 17: ...For AC Power Install a Siemens S10K30MOV Metal Oxide Varistor provided or equivalent REQUEST TO EXIT GROUND STATUS NORMALLY OPEN COMMON COMMON NORMALLY CLOSED NORMALLY CLOSED COMMON OR DOOR 1 or 2 RE...

Страница 18: ...ts tab Then select the desired relay on the left hand side 1 through 4 3 Press LEARN button on gate operator Press and release the LEARN button on the primary operator The green XMITTER LED will light...

Страница 19: ...nshielded wires should be kept to a minimum to avoid electrical noise RED LED brown GREEN LED orange DATA 1 white DATA 0 green GROUND black 12Vdc red READER OR KEYPAD WIEGAND LIGHT LOAD LINE NEUTRAL I...

Страница 20: ...DC 1 Amp max Green White Yellow White The gray blue and brown wires from the RFID Reader are unused Green Black DOOR BOARD Door 1 Door 2 WIEGAND INPUT PRIMARY RELAY AUXILIARY RELAY AUXILIARY RELAY REQ...

Страница 21: ...f the resident that granted access And Or Successful access through Entry Code The CAPXM will provide a myQ Business specified facility code followed by the successful Entry Code And Or Successful acc...

Отзывы: