709156-2GB
G
B
-7
Timer Control:
In order to program the timer control briefly push (max. 2sec) first lowermost button “P” then Open-
/Close-button.
Example:
Push button “P” at 7am. The LED will start flashing. Then briefly push Open-/Close-button; the shutter
will move to the upper limit and the LED will glow.
Daily opening is now pre-programmed to 7am.
Push button “P” at 8pm. The LED will start flashing. Then briefly push Open-/Close-button; the shutter
will move to the lower limit and the LED will glow.
Daily closing is now pre-programmed to 8pm.
Deactivating / Activating / Changing timer control:
Deactivating
- Briefly push button “P” (max. 2sec). Timer control is deactivated, the pre-programmed
times remain stored. LED will flash for approx. 5sec and will then stop flashing.
Activating
- By pushing button “P” again (max. 2sec) the shutter will open/close at pre-programmed
times. LED will flash for approx. 5sec and will the stay on.
Changing
- Programming at desired times as described under Timer Control. Pre-programmed times
will be overwritten.
Adjusting / Deleting / Changing additional positioning:
Adjusting
Keep pushing Open-/Close-button until shutter is in desired position
Then push button “P” until LED stops flashing
The additional position is programmed
Deleting
Keep pushing Open-/Close-button; the shutter will open or close completely
As soon as upper/lower limit is reached shutter will stop moving
Now push button “P” until LED stops flashing
The additional position is deleted
Changing
See Adjusting
Pre-programmed additional positioning will be overwritten
Reset (delete all settings):
Push the Reset-button using a pointed device, e.g. ballpoint pen (see control panel description). All
previously pre-programmed settings will be deleted. The motor is back to its factory setting. Pushing
any one of the white buttons on the control panel will lead to new initial set up / measuring of window
size.
Removal of motor:
Close shutter completely.
Pull the plug from wall socket, if necessary detach light sensor from window. Extract screw from strap-
spool cover on the side of the shutter strap coiler using a screw driver (see fig.3), so that you can lift
off the strap spool cover by the screw. (see fig.4). Now remove the strap from the strap spool (see
fig.7) and pull it out from the top of the shutter strap coiler. Loosen both fastening screws of the shut-
ter strap coiler using a screw driver (see fig.2) and readjust the strap spool cover, refastening it with
the centre screw (fig.3).