background image

M

 

M

 

WARNING

 

To prevent possible SERIOUS INJURY or DEATH from electrocution: 
• Be sure power is not connected BEFORE installing the receiver. 
To prevent possible SERIOUS INJURY or DEATH from a moving gate 
or garage door: 
• ALWAYS keep remote controls out of reach of children. NEVER 

permit children to operate, or play with remote control transmitters. 

• ACTIVATE gate or door ONLY when it can be seen clearly, is properly 

adjusted, and there are no obstructions to door travel. 

• ALWAYS keep gate or garage door in sight until completely closed. 

NEVER permit anyone to cross path of moving gate or door. 

PREPARATION 

Set power supply voltage 

CAUTION

 

The use of 24V with the jumper in 12V position will cause permanent 
damage to the receiver. 

The receiver can be powered with either 24V AC/DC or with 12V 
DC. The jumper must be in the 24V position for use with 24V, 
and in 12V position for use with 12 VDC. The jumper must be set 
to the proper voltage to avoid damage to the receiver. 

The receiver is factory set at 24V (Figure 1). 

Set security mode 

The 412HM Universal Receiver can be used with up to 15 rolling 
code transmitters or passwords in HIGH security mode. 
Alternately, it can be used with up to 31 of any type transmitter in 
NORMAL security mode, including any combination of rolling 
code, billion code, or dip switch remotes. 

The jumper must be set at the HIGH position for the receiver to 
operate in HIGH security mode. It must be set at NORMAL 
position to operate at the NORMAL mode (Figure 2). 

When changing from NORMAL to HIGH security mode, any 
previous transmitter codes must be erased. Repeat Steps 2 and 
3 on Side 2 to reprogram the receiver for each remote control 
transmitter in use. 

The receiver is factory set at HIGH. 

Set output duration 

(Commercial Applications Only) 

WARNING

 

To prevent possible serious injury or death, the use of 
CONSTANT OPERATION on residential openers is PROHIBITED. 

For commercial applications, the receiver can be set for either 
constant or momentary closure on the output contacts. Use of 
constant closure is prohibited on residential garage door openers 
because it overrides the safety reversal devices. 

With the jumper in the “M” (Momentary) position, the contacts will 
close for 1/4 second regardless of the length of radio transmission. 
With the jumper in “C” (Constant) position, the contacts will stay 
closed as long as the radio continues transmitting (Figure 3). 

The receiver is factory set at M. 

Universal Radio Control 

OWNERS MANUAL 

Model 412-315HM 

NOTICE:  To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of 
this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the 
battery.  THERE ARE NO OTHER USER SERVICEABLE PARTS. 
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE.  Operation is subject to the 
following two conditions:  (1) this device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired operation. 

Jumper 

Circuit 

Power Supply 

Circuit 

Power Supply 

Jumper 

Board 

Terminals 

Board 

Terminals 

24V POSITION 

12V POSITION 

FIGURE 1 

Security Mode 

Jumper 

Security Mode 

Jumper 

Terminals 

Terminals 

HIGH 

NORMAL 

SECURITY MODE 

SECURITY MODE 

FIGURE 2 

CONSTANT 

J

u

mper 

MOMENTARY 

J

u

mper

OPERATION 

OPERATION 

O

u

tp

u

O

u

tp

u

D

u

ration 

D

u

ration 

Terminals 

Terminals 

FIGURE 3 

Содержание Liftmaster PROFESSIONAL 412-315HM

Страница 1: ...vious transmitter codes must be erased Repeat Steps 2 and 3 on Side 2 to reprogram the receiver for each remote control transmitter in use The receiver is factory set at HIGH Set output duration Commercial Applications Only WARNING To prevent possible serious injury or death the use of CONSTANT OPERATION on residential openers is PROHIBITED For commercial applications the receiver can be set for e...

Страница 2: ...light will glow steadily for 30 seconds Figure 7 3 Within 30 seconds press and hold the button on the hand held remote that you wish to operate your garage door The opener will now operate when the push button on either the receiver or the remote control transmitter is pressed Repeat Steps 2 and 3 for each remote control that will be used to operate the garage door opener To erase all remote contr...

Страница 3: ...l modo de seguridad de NORMAL a HIGH Repetir los pasos 2 y 3 en el lado 2 para reprogramar el receptor para cada transmisor de control remoto en uso El receptor se gradúa de fábrica a HIGH Graduación de la duración de la salida Aplicaciones Comerciales Solamente ADVERTENCIA El uso de OPERACION CONSTANTE en abridores residenciales está PROHIBIDO para prevenir LESIONES GRAVES o MUERTE posibles Para ...

Страница 4: ...or 30 segundos Figura 7 3 En 30 segundos oprimir y mantener oprimido el botón en el remoto manual con el cual sedesea operar la puerta del garage El abridor opera ahora cuando se oprime el botón en el receptor o el transmisor de control remoto Repetir los pasos 2 y 3 para cada control remoto ques e usa para operar el abridor de la puerta del garage Para borrar todos los códigos de control remoto O...

Отзывы: