Page 2

Dimensions

Dimensions

Caution! A Static Discharge can Damage Circuit Boards

6 in.

3-15/16 in.

Mounting Holes (4) 
for 5/16 in.

3/4 in. Conduit Hole

1-1/4 in. Conduit Hole

Knockouts for 5/16 in.

Knockouts for 3/8 in.

15 in.

AUG 10, 2005

WELCOME

3-1/16 in.

9 in.

1-5/8 in.

2 in.

12 in.

7 in.

9-1/2 in.

6 in.

3-1/16 in.

1-1/2 in.

1/2 in.

EL2000 Units

EL25 Units

Содержание LiftMaster ELITE EL2000

Страница 1: ...Telephone entry access control system 2008 The Chamberlain Group Inc All Rights Reserved Installation Manual for Installation Manual for EL MODELS EL MODELS ...

Страница 2: ......

Страница 3: ...ring to Dedicated Telco Line 12 Wiring to an Internal Phone System 13 Connection to an NPBI System 14 External Devices Wiring a Door Strike Lock 15 Wiring a Maglock 15 Wiring a Gate Operator 16 Wiring a Key Switch PIR REX 16 Wiring a Door Sensing Device 17 Wiring the AutoCall Feature 17 Wiring a Radio Frequency Module 18 Wiegand Card Reader Keypad 18 Wiring a Postal Lock Switch 19 Wiring an Intern...

Страница 4: ...cuit Boards 6 in 3 15 16 in Mounting Holes 4 for 5 16 in 3 4 in Conduit Hole 1 1 4 in Conduit Hole Knockouts for 5 16 in Knockouts for 3 8 in 15 in AUG 10 2005 WELCOME 3 1 16 in 9 in 1 5 8 in 2 in 12 in 7 in 9 1 2 in 6 in 3 1 16 in 1 1 2 in 1 2 in EL2000 Units EL25 Units ...

Страница 5: ...1 Microphone NOTE Bracket notch lines up with ribbon cable on keypad Caution A Static Discharge can Damage Circuit Boards For EL25 ONLY Caution A Static Discharge can Damage Circuit Boards 1 Unlock Unit 2 Carefully Lift Cover Up then Slide Out on Hinges 3 Unplug the 2 Main Harnesses 4 Line up Notch with Screw and Push Hinge Out 5 Remove Back Mounting Plate from Cover 1 Disconnect all Plugs from Ma...

Страница 6: ...r Locking EL2000 1 Turn key counter clockwise to lock position 2 Close cover 3 Apply pressure to left side until you hear a click sound 4 Apply pressure to right side of unit until you hear a click sound 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 2 3 2 1 3 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 4 1 ...

Страница 7: ...n EL2000 Installation 1 Unlock Unit 2 Open Cover 3 Unplug the 2 Main Harnesses Optional 4 Slide Front Cover Out of Hinges Optional 6 Mount Back Housing to Wall or Pedestal 5 Knock out Desired Mounting Plugs Using Punch NOTE This unit is for surface and recessed mount ONLY ...

Страница 8: ...M 12 Relay 2 NO NC COM 13 Relay 1 NO NC COM NOTE All relays are factory set to Strike and 10 sec DO NOT overload the removable terminal block connectors One wire per hole 20 Pin to Main Board 14 Pin to Main Board IO Output Board IO Input Board J2 J3 LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 8 9 DOOR STAT 4 EXIT REQ 4 COM 4 3 2 1 5 6 7 10 11 12 13 DOOR STAT 3 EXIT REQ 3 COM DOOR STAT 4 EXIT REQ 2...

Страница 9: ... 17 17 18 18 18 19 19 NOTE Use metal conduit run wires in metal conduit instead of PVC pipe Wires run in PVC conduit may experience interference Metal conduits also add extra protection against lightning strikes Never run Telco Wires and High Voltage wires in the same conduit The high voltage may interfere with the Telco Wires possibly causing the system to malfunction Total distance from Telco to...

Страница 10: ...ector s office in the municipality where you plan to install the unit for correct grounding materials and installation procedures Other Ground Sources within 12 ft of Unit Green Ground Wire Earth Ground Rod Ground to Existing Electrical System Electrical Panel Ground to Metallic Cold Water Pipe 12 ft Maximum 12 AGW Minimum 1 2 3 4 5 6 7 8 9 AUG 10 2005 WELCOME 1 2 3 4 10 11 5 6 7 8 9 10 12 11 OR N...

Страница 11: ...M Bypass Board Mount in the House NOT Provided Ring Tip Ring Tip Home Phone Alarm System Position Use 18 24 AWG 2 twisted pair NOTE If the unit will be used in conjunction with an alarm system you MUST connect the telephone line to the alarm system first If the units are not connected in this order they will not operate properly 4 4 3 2 1 3 2 1 Output Board See page 6 Telco Entrance Box Demarcatio...

Страница 12: ... HOME Tip Ring TELCO Tip SYSTEM 4 3 2 1 BYPASS Ring TELCO Tip Bypass Board for Unit 1 Bypass Board for Unit 2 Ring Ring Ring Tip Tip Tip Ring Tip Use 18 24 AWG 2 twisted pair IMPORTANT You must program the unit ID s for each unit wired in the series See Keypad Programming Manual OPERATE BYPASS Ring HOME Tip Ring TELCO Tip SYSTEM 4 3 2 1 Last Bypass Board 4 3 2 1 Home Phone Unit ID 1 Output Board S...

Страница 13: ...ires may interfere with the Telco wires possibly causing the system to malfunction Multiple Units Up to 7 Tip Ring Tip Ring RES TELCO Tip Ring Tip Ring RES TELCO To next unit Unit ID 3 then 4 etc Use 18 24 AWG 2 twisted pair IMPORTANT You must program the unit ID s for each unit wired in the series See Keypad Programming Manual IMPORTANT Only disable the Telco mode of the unit farthest away from t...

Страница 14: ...gh Voltage wires in the same conduit The high voltage wires may interfere with the Telco wires possibly causing the system to malfunction Use 18 24 AWG 2 twisted pair IMPORTANT You must program the Unit ID s for each unit wired in the series See Keypad Programming Manual Unit ID 6 Output Board See page 6 Unit ID 7 Output Board See page 6 Use 18 24 AWG 2 twisted pair Telco Entrance Box Demarcation ...

Страница 15: ...es in the same conduit The high voltage wires may interfere with the Telco wires possibly causing the system to malfunction Single Unit Multiple Units Up to 7 IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J8 Tip Ring Tip Ring IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO ...

Страница 16: ...3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J8 Tip Ring Never run Telco wires and High Voltage wires in the same conduit The high voltage wires may interfere with the Telco wires possibly causing the system to malfunction Use 18 24 AWG 2 twisted pair IMPORTANT You must program the Unit ID s for each unit wired in the series See Keypad Programming Manual Unit ID 6 Output Boa...

Страница 17: ...nal block connectors One wire per hole Output Board See page 6 For DC Power Install a 1N4005 diode or equivalent For AC Power Install a Siemens S10K30 MOV Metal Oxide Varistor or equivalent IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J8 Output Board See page 6 Install a 1N4005 diode or equivalent NOTE The maglock ...

Страница 18: ...D 3 RES TELCO J6 J8 Use 18 24 AWG NOTE The gate operator can be connected to any of the 4 relays Normally Open Common DO NOT overload the removable terminal block connectors One wire per hole Output Board See page 6 IO Input Board J2 J3 DOOR STAT 4 EXIT REQ 4 COM DOOR STAT 3 EXIT REQ 3 COM DOOR STAT 4 EXIT REQ 2 COM DOOR STAT 1 EXIT REQ 1 COM J5 J7 J6 J4 POSTAL AUTO J1 POWER 12VAC DC Use 18 24 AWG...

Страница 19: ... when a driveway sensor is activated any device that provides a contact closure For example when a visitor drives over a loop sensor that is connected to the AutoCall feature the unit will call the main residence phone automatically so the visitor can speak to the resident without pressing the call button on the unit IO Input Board J2 J3 DOOR STAT 4 EXIT REQ 4 COM DOOR STAT 3 EXIT REQ 3 COM DOOR S...

Страница 20: ...th your Wiegand device for more information RG 6 Coaxial Connector RG 6 Coaxial Cable 100 Feet Maximum Remote Antenna Avoid any metallic surface around the antenna RF Module s will fit in positions J400 Device 1 and or J407 Device 3 4 Mounting Screws per Board are Required 1 RF Module Kit Part RFMODKT 390 MHz or Part RFMODKT3 315 MHz J407 Position J400 Position Card Reader is Wired to Device 1 P12...

Страница 21: ...al Wiring an Internal Camera CCTV An Optional CCTV Close Circuit Television camera can be installed inside the unit Refer to instructions supplied with the camera kit for more information IO Input Board J2 J3 J5 J7 J6 J4 POSTAL AUTO J1 POWER 12VAC DC Use 18 24 AWG Common In N C Switch Input Board See page 6 DO NOT overload the removable terminal block connectors One wire per hole RG 59u Coaxial Ca...

Страница 22: ...tlet after all connections have been made Any other type of outlet will cause damage to the system IO Input Board J2 J3 J5 J7 J6 J4 POSTAL AUTO J1 POWER 12VAC DC Off Off Off Off On On On On On On Off Off Off Off Off Off On On Off Off Off Off EL Model Main Room Eug Rm Oper Rm Eug Dept Manu 1 Rm Main Dept Manu 2 Rm Air 1 Conditioner Air 2 Conditioner Conference Room 1 Conference Rm 2 3 Refer Bus 1 2...

Страница 23: ... Monitoring Connector J404 X X LED Power Supply Connector J407 X X Module Device 3 4 Connect a module Wiegand or RF device here The device address becomes 3 RF or Wiegand J1 or 4 Wiegand J2 Connector J400 X X Module Device 1 2 Connect a module Wiegand or RF device here The device address becomes 1 RF or Wiegand J1 or 2 Wiegand J2 Connector J300 X LCD Data Data wires for LCD Display Connector BT300...

Страница 24: ...ice not working Short IN and COM pin connections to verify functionality If wiring is correct and device still does not work contact technical support Card Reader not communicating with Unit Make sure Wiegand is configured to a door program step 60 Check Wiegand reader module connections Connect and test a functioning reader Make sure reader is not defective Did you add the card s to the database ...

Страница 25: ...n Nickel Actuator Call Button Mist Gray E Ring Call Button Spring Call Button Gasket Back Assembly Lock EL25 Focus Key Assembly Speaker EL25 93D341 93D341 1 93D341 2 108B81 108B81 1 101A159 101A159 1 101A159 2 158A94 177A166 84B81 1 2B809 41B12 2B639 Assembly LED Focus Assembly Mic Cable EL25 Gasket Key Pad Assembly Keypad 16 Button Assembly EL25 Main Board Assembly PCB Output Board Focus Assembly...

Страница 26: ...Assembly Gray EL2000 Housing Assembly Nickel Door Interconnect Cables Kit Assembly Speaker EL Series Assembly Call Button Board EL2000 Postal Lock Switch EL2000 41B989 41B990 2B737 2B736 2B735 2B705 2B704 41B991 41B992 41B993 41B994 2B639 41B995 41B996 Interconnect Board Assembly Lock and Key EL2000 Replacement Key Assembly Keypad 16 Button Gasket Keypad Assembly Mike Cable EL Series Assembly Entr...

Страница 27: ...Page 25 Your System Diagram Your System Diagram ...

Страница 28: ...________________________________ Default Internal Keypad Relay Connections Output Board Relay 1 ________________________________________________________________________________ Relay 2 ________________________________________________________________________________ Relay 3 ________________________________________________________________________________ Relay 4 _____________________________________...

Страница 29: ...r o o D e m a n e R e c i v e D e h t r o f r e d a e R n a i r t s e d e P t c e l e s 3 p u o r G n a i r t s e d e P t c e l e S u n e m n w o d p o r d e h t m o r f 4 E V A S k c i l C 5 e h t k c e h c n U e c i v r e S e n o h p e l e T e s U x o b k c e h c 2 e h t n o k c i l C n o t t u b t i d E 1 e t a G n a i r t s e d e P 5 5 e s e h T e n i l e n o h p e n o h t i w e m o h y l i m ...

Страница 30: ...company DOC Requirements Notice The Canadian Department of Communications label identifies certified equipment This certification means that the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permi...

Страница 31: ......

Страница 32: ...845 Larch Avenue Elmhurst Illinois 60125 1196 114A2980F 2008 The Chamberlain Group Inc All Rights Reserved ...