Current
input
(A)
0,53
0,60
0,83
0,86
0,89
1,43
1,54
0,53
0,64
Motor
rating
(W)
121
133
191
198
205
330
345
121
145
Limit switch
range
(revolutions)
39 +/- 1
23 +/- 1
23 +/- 1
23 +/- 1
23 +/- 1
21,5 +/- 1
21,5 +/- 1
39 +/- 1
23 +/- 1
en-2
Carton Contents
1.
Motor
(1)
2.
• Adjuster pin
(2)
• Drive adapter safety catch
(3)
• Square pin
(4)
• Shaft adapter
(5)
• Wall bracket
(6)
3.
Manual
A
Performance features
Model
CRX101
CRX151
CRX251
CRX401
CRX501
CRX800
CRX1000
CRX0628
CRX1026
Diameter*
(mm)
35
45
45
45
45
59
59
35
45
Torque
(Nm)
10
15
25
40
50
80
100
6
10
Speed
(rpm)
17
15
15
15
12
15
12
28
26
Operating
Voltage
(V)
230
230
230
230
230
230
230
230
230
Frequency
(Hz)
50
50
50
50
50
50
50
50
50
Operating
time
(min)
4
4
4
4
4
4
4
4
4
*Smallest possible tube diameter
for operators with body diameter of 35mm
= 39mm
Smallest possible tube diameter
for operators with body diameter of 45mm
= 50mm
Smallest possible tube diameter
for operators with body diameter of 59mm
= 70mm
Fully unroll the shutter
(a)
. Remove the shutter material from
the tube
(b)
. Remove the manual control
(c)
.
C
B
a
c
b
Remove the tube.
INSTALLATION
Rough- in or install conduit pipe to the connector box for the electrical connecting line according to local building and electrical codes.
THE DRIVE IS PREMOUNTED. THE DESCRIPTION IS FOR CHECKING PURPOSES!
Correct use
The CRX101 - CRX1026 tubular drives are designed for the exclusive purpose of operating shutters and sun-blind systems.
They serve to open and close these systems and replace the person that is usually operating the installation.
Therefore, tubular drives may only be installed in faultless shutter- or sun-blind systems. Rough-running systems have to be repaired.
Replace defective parts. This guarantees safe operation and avoids damage during opening or closing.
Any other form of usage is deemed to be incorrect. Neither the manufacturer nor the supplier assumes any liability for personal injury, damage to
property or consequential injury or damage occurring as a result of the use of the control units and / or drives for purposes other than those
mentioned above or due to changes made to the equipment affecting the safety of the given system.
The details stipulated in the Operating Instructions in respect of the operation and repair of the system require strict observance.
Neither the
manufacturer nor the supplier assumes any liability for personal injury, damage to property or consequential injury or damage occurring
as a result of non-compliant actions.
In compliance with standard
EN 60 335-2-97:2000
, the cable connecting the drives to the mains cable must be laid internally.
According to
DIN 18073
shuter box lid must always be easily accessible and removable.
A
4
5
5
6
1
2
3
CRX101 - CRX501
CRX800, CRX1000 only
not included in CRX800, CRX1000
A