![Chamberlain J Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/chamberlain/j/j_instructions_2586669003.webp)
3
EMERGENCY EGRESS FEATURE
(1A4651 OPTIONAL EMERGENCY EGRESS KIT)
EMERGENCY EGRESS
REMOVE LOCKS
PULL HANDLE DOWN FULLY
OPEN GRILLE GATE
Disconnect
Cable
Disconnect
Lever
Frame
Upper Stop
Pin
Lower Stop
Pin
1
Disconnect
Lever
Disconnect
Lever
Z-Bend
Z-Bend
SIDE VIEW
Frame
Upper Stop Pin
Lower Stop
Pin
#8 Thread
Forming Screws
Flexible
Conduit
14-1/2" Diameter
Minimum
Flexible
Conduit
Handle in
UP Position
1 Loop
Maximum
Mount Egress
Box to Wall Studs
or Similar Supports
Conduit
Clamp
2
3
4
Disconnect all electric power before
proceeding with installation.
WARNING
1. Remove disconnect cable from disconnect lever.
2. Attach wire end of flexible conduit cable to
disconnect lever. Insert Z-bend through hole.
3. Fasten flexible conduit to frame with conduit
clamp and two #8 thread forming screws,
tighten securely.
CAUTION:
For proper operation make sure
that disconnect lever is against upper stop
pin and handle on emergency egress unit is
in the UP position before securing conduit
clamp.
4. Mount egress unit box to wall stud or similar
support. Flexible cable must be kept as straight as
possible. If necessary, one (1) coil with a minimum
diameter of 14-1/2 inches may be used to shorten
the length of the cable. Check disconnect function
several times before reconnecting electric power.
5. Reconnect electric power.