EMERGENCY EGRESS FEATURE

(1A4651 OPTIONAL EMERGENCY EGRESS KIT)

EMERGENCY EGRESS

REMOVE LOCKS

PULL HANDLE DOWN FULLY

OPEN GRILLE GATE

Disconnect

Cable

Disconnect

Lever

Frame

Upper Stop

Pin

Lower Stop

Pin

1

Disconnect

Lever

Disconnect

Lever

Z-Bend

Z-Bend

SIDE VIEW

Frame

Upper Stop Pin

Lower Stop

Pin

#8 Thread

Forming Screws

Flexible
Conduit

14-1/2" Diameter

Minimum

Flexible
Conduit

Handle in

UP Position

1 Loop

Maximum

Mount Egress

Box to Wall Studs

or Similar Supports

Conduit

Clamp

2

3

4

Disconnect all electric power before
proceeding with installation.

WARNING

1.  Remove disconnect cable from disconnect lever.

2.  Attach wire end of flexible conduit cable to

disconnect lever. Insert Z-bend through hole.

3.  Fasten flexible conduit to frame with conduit 

clamp and two #8 thread forming screws,
tighten securely.

CAUTION:

For proper operation make sure

that disconnect lever is against upper stop 
pin and handle on emergency egress unit is 
in the UP position before securing conduit
clamp.

4.  Mount egress unit box to wall stud or similar

support. Flexible cable must be kept as straight as
possible. If necessary, one (1) coil with a minimum
diameter of 14-1/2 inches may be used to shorten
the length of the cable. Check disconnect function
several times before reconnecting electric power.

5.  Reconnect electric power.