background image

DIAGNOSTICS

+

-
- -

3
2
1

10W 12V

10W 12V

Entrapment Zone

CONTROL BOARD

J15 Plug

Bridge Rectifier

7AH Solar Battery

Harness K94-36891

Power Wiring Sockets

(120 Vac

factory default) 

Power Wiring Connector

Transformer

Orange

Orange

Battery

12V 7AH

Battery

12V 7AH

Gray
Blue

Brown
Purple

Black

Black

Black

Black

White

Green

HOT

NEUTRAL

GROUND

EMI BOARD

Photoelectric Sensors

White

Red

Red

Red

Red

AC Power Switch 

Piggy Back

Solar Panels (Optional)

20W minimum - 60W maximum, 

wired in series

Incoming Power

Blue

Brown

WIRING AND ADJUSTMENTS

INITIAL LIMITS AND FORCE ADJUSTMENT

1.  Press and release the SET 

OPEN and SET CLOSE buttons 

simultaneously to enter limit 

setting mode.

2.  Press and hold one of the 

MOVE GATE buttons to move 

the gate/door to the open or 

close limit.

3.  Press and release the SET 

CLOSE or SET OPEN button 

depending on which limit is 

being set.

4.  Press and hold one of the 

MOVE GATE buttons to move 

the gate/door to the other 

limit.

5.  Press and release the SET 

CLOSE or SET OPEN button depending on which limit is being set.

6.  Cycle the gate/door open and close. This automatically sets the 

force.

When limits are set properly the operator will automatically exit limit 

setting mode.

FINE TUNE THE FORCE

The REVERSAL FORCE DIAL on the control board is used for fine 

tuning the force in cases where wind or environmental changes 

may affect the gate/door travel. Based on the length and weight of 

the gate/door it may be necessary to make additional force 

adjustments. The force setting should be high enough that the 

gate/door will not reverse by itself nor cause nuisance 

interruptions, but low enough to prevent serious injury to a 

person. The force setting is the same for both the open and close 

gate/door directions.
1.  Open and close the gate/door 

with the TEST BUTTONS.

2.  If the gate/door stops or 

reverses before reaching the 

fully open or closed position, 

increase the force by turning 

the force control slightly 

clockwise. 

3.  Perform the “Obstruction 

Test” after every force setting 

adjustment.

1.  Open and close the gate/door with the TEST BUTTONS, ensuring 

that the gate/door is stopping at the proper open and close limit 

positions.

2.  Place a solid object under the open gate/door. Ensure that the 

gate/door, and the solid object can withstand the forces 

generated during this obstruction test.

3.  Run the gate/door in the close direction. The gate/door should 

stop and reverse upon contact with the solid object. If the gate/

door does not reverse off the solid object, reduce the force 

setting by turning the force control slightly counter-clockwise. 

The gate/door should have enough force to reach both the open 

and close limits, but MUST reverse after contact with a solid 

object.

Are all the wiring and connections tightly connected?

Is the AC power on? If the operator is left running on battery only, it 
will drain the battery and will result in a service call.

Check the batteries and battery connections. Make sure there are two 
12V batteries. Replace batteries if depleted to less than 20V.

Remove the protective anti-scratch film from the photoelectric 
sensors. Leaving the film on can result in poor sensitivity as the film 
decays/yellows/peels.

Confirm whether the site should be fail safe or secure and set the 
operator accordingly. 

Confirm operation of the following (if applicable):

Entrapment protection devices

Loops

TES relay

SOS/emergency transponders

Check operation of ALL legacy receivers using the MAX transmitter

Timer-to-Close setting

Quick close setting

Anti-tailgate setting

Check the following before leaving the site:

Turn off the AC power from the main power source circuit 

breaker. Connect the earth ground rod, incoming power, and 

batteries (see images below). The operator can be wired for 120 

or 240 Vac by choosing the desired power wiring socket on the 

EMI board. Refer to your manual for complete wiring 

information.

The HCTDCU provides a high speed open option to help flow in 

high traffic areas. Select the open speed using the BIPART 

DELAY switch.
BIPART DELAY OFF (default) = 8 in./sec. open speed
BIPART DELAY ON (fast) = 11 in./sec. open speed

Install Monitored Entrapment Protection Device

Connect Power Wiring and Earth Ground Rod

Set Open Speed

Set the Limits and Force

Perform the Obstruction Test

Installation Checklist

This operator contains an inherent (internal) entrapment protection 

system and REQUIRES the addition of a LiftMaster external 

monitored entrapment protection system (non-contact photoelectric 

sensor or contact edge sensor) for EACH entrapment zone prior to 

gate movement. 

System includes six monitored entrapment 

protection inputs capable of covering all entrapment zones. Refer to 

the manual for complete information.