7
7.5"
(19.1 cm)
4.1"
(10.3 cm)
7.8"
(19.9 cm)
17.5"
(44.5 cm)
HCT08: 8' (2.4 m) rail
HCT10: 10' (3.1 m) rail
HCT12: 12' (3.7 m) rail
23.8"
(60.3 cm)
OPERATOR SPECIFICATIONS
INTRODUCTION
Usage Classification
Class II, III, and IV
Main AC Supply
120 Vac, 4 Amps
OR
240 Vac, 2 Amps
System Operating Voltage
24 Vdc Transformer Run / Battery Backup
Accessory Power
24 Vdc, 500mA max. for ON + SW (switched)
Solar Power Max
24 Vdc at 60 watts max.
Variable Operating Lengths
8 foot (2.4 m) gate - 11.75 foot (3.6 m) operator length
10 foot (3.1 m) gate - 13.75 foot (4.2 m) operator length
12 foot (3.7 m) gate - 15.75 foot (4.8 m) operator length
Maximum Gate/Door Weight
700 lbs. (317.5 kg)
Maximum Gate/Door Width (sectional and one-piece)
22 ft. (6.7 m)
Travel Speed
Default - 8 inches (20.3 cm) per second
Fast - 11 inches (27.9 cm) per second (open speed only)
Maximum Daily Cycle Rate
Continuous
Maximum Duty Cycle
Continuous
Operating Temperature
-20°C to 60°C (-4°F to 140°F)
Expansion Board
Provided
Inherent Entrapment Protection (Type A)
Dual - RPM and Current Sense
External Entrapment Protection (Type B1 and/or Type B2)
3 inputs per board - any combination of up to 3 photoelectric sensors and up to 2
edge sensors