Replacementparts
1.
041A5644
Trolley with chain/cable assy (GPD60)
001A6355-3
Trolley with chain/cable assy (GPD65)
2.
001A5690-35 Head only (GPD60)
001A5690-36
Head only (GPD65)
3.
001A5643-6
Hardwarebag
4.
012B0905
Door bracket
012B0906
5.
012C0908
Rail end bracket
6.
012C0788 Header
bracket
7.
001B0911
C-rail clamp (GPD65)
8.
05765 Rail
hardware
9.
183D0181-3
Rail parts (GPD65)
10.
041A5676
Rail parts (GPD60)
11.
041C0521-1
Limit switch (GPD60)
041A0521-2
Limit switch (GPD65)
12.
001A4166
Push button
13.
001B4494-1
Wire
14.
041A0079
Lightbulb
24
en-5
Accessories
(1) Model 84330EML
Single-Function Remote Control
(2) Model 84333EML
3-Function Remote Control
(3) Model 84335EML
3-Function Mini Remote Control
(4) Model 8747EML
Keyless Entry System
(5) Model 845EML
Multi-Function Door Control Panel
(6) Model 760EML
Outside Keylock
(7) Model 1702EML
Outside Quick Release
(8) Model 770EML
The Protector System™
(9) Model 1703EML
The Chamberlain Arm™
(10) Model 75EML
Lighted Door Control Button
(11) Model 1EML
Door Handle Quick Release
(12) Model 41EML
2 Position Key Switch
NOT SHOWN:
Model MDL100EML
Mechanical Door Latch
WIRING INSTRUCTIONS FOR ACCESSORIES
Outside Keylock – To opener terminals: Red-1 and White-2
Protector System™ – To opener terminals: White-3 and Grey-4
Door Control Panel – To opener terminals: Red-1 and White-2
22
Wiring the Lighted Door Control Button
(Optional)
Locate any Wall Mounted Door Control where the garage door is visible, away
from door and door hardware, at a minimum height of 1.5m. fasten the child
warning label on the wall near the Door Control.
There are 2 screw terminals (1) on the back of the Door Control (2). Strip about
6mm of insulation from bell wire (4). Separate wires enough to connect the white/red
wire to terminal screw 1 and the white wire to terminal screw (1)
Lighted Door Control Button:
Fasten to an inside garage wall with sheet metal
screws (3) provided with Lighted Push Button. Drill 4mm holes and use anchors (6)
if installing into drywall or concrete. A convenient place is beside the service door
and
out of reach of children.
Run the bell wire up the wall and across the ceiling to the garage door opener. Use
insulated staples (5) to secure wire.
The opener Quick-Connect Terminals (7) are located in the recess next to the learn
button on the left side panel. Insert bell wire into holes in the Quick Connect
Terminals as follows: Red/White to Red and White to White.
Install Protector System™
(Optional) – (See accessories)
After opener has been installed and adjusted,
The Protector System™
accessory
can be installed. Instructions are included with this optional device.
The Protector System™ provides an additional measure of safety against a
small child being caught under a garage door.
It uses an invisible beam which, when broken by an obstruction, causes a closing
door to open and prevents an open door from closing and is
strongly recommended
for homeowners with young children.
23
Specifications
Input Voltage . . . . . . . . . . . . . . .230 VAC 50Hz
Max. Pull force . . . . . . . . . . . . . .600N (GPD60), 650N (GPD65)
Rated Power Input . . . . . . . . . . .85 Watts
Rated Load . . . . . . . . . . . . . . . .3.0 Nm
Standby Power . . . . . . . . . . . . . .9 Watts
Max. Door Weight . . . . . . . . . . .60kg (GPD60), 80kg (GPD65)
Motor
Type . . . . . . . . . . . . . . . . . . . . . .63:1 Worm Gear Reduction
Volts . . . . . . . . . . . . . . . . . . . . . .24VDC
Drive Mechanism
Length of Travel . . . . . . . . . . . . .2,3 m (GPD60), 2,5 m (GPD65)
Travel Rate . . . . . . . . . . . . . . . .8cm/sec
Lamp . . . . . . . . . . . . . . . . . . . . .24V 21 Watts
Safety
Electronic . . . . . . . . . . . . . . . . . .Auto-Force Adjustment
Electrical . . . . . . . . . . . . . . . . . .Thermal Fuse in Transformer
Limit Adjustment . . . . . . . . . . . . .Manual
Dimension
Length (Overall) . . . . . . . . . . . . .2,75 m (GPD0), 3,05 m (GPD65)
Headroom Required . . . . . . . . . .30mm
Hanging Weight . . . . . . . . . . . . .9kg (GPD60), 9,5kg (GPD65)
Receiver Code Registers
Rolling Code . . . . . . . . . . . . . . .8
Operating Frequency . . . . . . . . .433.92MHz
D e c l a r a t i o n o f C o n f o r m i t y
The undersigned, hereby declare that the equipment specified, and all
accessories, conforms to the Directives and Standards stated.
Model:....................................................................................GPD60/GPD65
2004/108/EC
2006/95/EC
1999/5/EC
EN55014-1 (2000), EN55014-2 (1997), EN61000-3-2 (2000), EN61000-3-3
(1995), EN 301 489-3 (V1.3.1), EN 300 220-3 (V1.1.1), EN60335-1 (1994),
and EN60335-2-95 (2000)
D e c l a r a t i o n o f I n c o r p o r a t i o n
A power door operator, in combination with a Garage Door must be installed
and maintained according to all the Manufacturer’s instructions, to meet the
provisions of EN12453, EN13241-1 and Machinery Directive, 98/37/EG.
B. P. Kelkhoff
Manager, Regulatory Affairs
Chamberlain GmbH
D-66793 Saarwellingen
January, 2009